Differential activation of trigeminal C or Adelta nociceptors by infrared diode laser in rats: behavioral evidence.

Radiant heat is often used for studying thermal nociception, although inherent characteristics such as the broad spectrum of applied wavelengths of typical light sources limit control over and repeatability of stimuli. To overcome these problems, we used a diode infrared laser-based stimulator (wavelength: 980 nm) for selectively stimulating trigeminal Adelta or C thermonociceptors in rats. To provide indirect evidence for nociceptor-selective stimulation, we tested the effects of capsaicin, dimethylsulfoxide (DMSO), and morphine on withdrawal latencies for long pulses with a low current (hypothesized to selectively stimulate C nociceptors) and for threshold currents of short pulses with high current (hypothesized to selectively stimulate Adelta nociceptors) in lightly anesthetized rats. Nonmem analysis was used to perform pharmacodynamic modeling. The measured baseline withdrawal latency for long pulses was 12.5 +/- 0.3 s which was changed significantly to 6.7 +/- 0.4 s after applying topical capsaicin which selectively sensitizes C nociceptors and to 16.5 +/- 1.3 s after 1.0 mg/kg morphine which preferentially attenuates C fiber nociception. Topical DMSO which appears to selectively sensitize Adelta afferents did not significantly alter withdrawal latencies to the long pulses. Fitted threshold currents for short pulses after DMSO were however significantly lower (974 +/- 53 mA vs. 1113 +/- 12 mA for baseline) indicating Adelta sensitization. Capsaicin and morphine did not significantly change threshold currents. Best Nonmem fits for the long pulse were obtained using a model assuming no DMSO effect, but a different inter-individual variability after applying this substance. For the short pulse, a model assuming no capsaicin or morphine effect, but again allowing different inter-individual variabilities after applying these drugs, best described the data. We conclude that different settings of the stimulator used in this study were capable of selectively activating trigeminal Adelta or C thermonociceptors.

Analgesics, Opioid↗

Variability of target-controlled infusion is less than the variability after bolus injection.

BACKGROUND: Target-controlled infusion (TCI) drug delivery systems deliver intravenous drugs based on pharmacokinetic models. TCI devices administer a bolus, followed by exponentially declining infusions, to rapidly achieve and maintain pseudo-steady state drug concentrations in the plasma or at the site of drug effect. Many studies have documented the prediction accuracy of TCI devices. The authors' goal was to apply linear systems theory to characterize the relation between the variability in concentrations achieved with TCI devices and the variability in concentrations after intravenous bolus injection. METHODS: The authors developed a mathematical model of the variability of any arbitrary method of drug delivery, based on the variability with intravenous bolus injection or the variability with an arbitrary infusion regimen. They tested the model in a simulation of 1,000 patients receiving propofol by simple bolus injection, conventional infusion, or a TCI device. The authors then examined an experimental data set for the same behavior. RESULTS: The variability of any arbitrary infusion regimen, including TCI, is bounded by the variability after bolus injection. This is observed in the simulation and experimental data sets as well. CONCLUSION: TCI devices neither create nor eliminate biologic variability. For any drug described by linear pharmacokinetic models, no infusion regimen, including TCI, can have higher variability than that observed after bolus injection. The median performance of TCI devices should be reasonably close to the prediction of the device. However, the overall spread of the observations is an intrinsic property of the drug, not the TCI delivery system.

Animals↗

Tutorial: context-sensitive decrement times for inhaled anesthetics.

Context-sensitive decrement times for inhaled anesthetics connect two values: a) the duration of anesthesia (nominally at a constant alveolar concentration)-the "context" and b) the time to decrease the alveolar or vital tissue (e.g., brain, heart, kidney, and liver, collectively called the vessel-rich group of tissues) concentration by some fractional "decrement" of the starting concentration. Increasing duration of anesthesia increases the time to a given decrement in a nonlinear manner that may considerably delay recovery. In the present report we use a commercially available simulation program (Gas Man) to confirm and enlarge on these concepts. In this simulation, increasing duration of anesthesia can markedly delay complete awakening for isoflurane. Increasing anesthesia duration imposes considerably less delay in awakening from sevoflurane compared with isoflurane. For desflurane, only prolonged anesthesia or decrements of 95% and more should delay awakening from anesthesia. These changes are shown to be the result of the relative solubility of each anesthetic in blood and tissue. An increase in cardiac output is also shown to delay awakening.

Anesthesia Recovery Period↗

Use of population modeling to define rational monitoring of amiodarone hepatic effects.

BACKGROUND: Amiodarone causes hepatotoxicity in experimental models, but in humans, the relationships between drug administration, serum concentrations, markers of liver function, and how to monitor for hepatotoxicity have not been well characterized. METHODS: An open-dose, prospective study collected serum amiodarone, desethylamiodarone, ALT, AST, lactate dehydrogenase (LDH), alkaline phosphatase, total bilirubin, and albumin concentrations over a 5-year period from 125 patients. Nonlinear mixed-effects modeling (NONMEM) was used to explore the relationship between markers of hepatotoxicity and concentrations of amiodarone and desethylamiodarone. RESULTS: No patients had clinical symptoms of hepatotoxicity during follow-up. The natural history of changes in hepatic makers showed ALT to have the strongest independent relationship to changes in serum amiodarone (r = 0.32, P <.001). An ALT greater than 3 times the upper limit of normal developed in only 8 patients (7%), with the earliest occurrence at 55 days of therapy. A mixed-effects model relating ALT elevation to serum amiodarone was improved by the addition of an effect compartment having an equilibration half-time of 87 days (r = 0.81, P <.001). The model predicts that 6% of patients will have an ALT greater than 3 times the upper limit of normal if amiodarone concentrations are maintained at less than 2.5 mg/L, and virtually no patients will have such ALT elevations if amiodarone concentrations are maintained at less than 1.5 mg/L. CONCLUSIONS: Concentrations of amiodarone below a threshold of 1.5 mg/L are associated with a minimal risk of hepatotoxicity, whereas concentrations greater than 2.5 mg/L are associated with a greater than 6% risk of hepatotoxicity. There is significant hysteresis between changes in amiodarone concentration and the resulting change in ALT. The model suggests that monitoring ALT at baseline, 1, 3, and 6 months, and then semiannually would be an efficient strategy to detect amiodarone-induced hepatotoxicity.

Aged↗

Mixed-effects modeling of the intrinsic ventilatory depressant potency of propofol in the non-steady state.

BACKGROUND: Despite the ubiquitous use of propofol for anesthesia and conscious sedation and numerous publications about its effect, a pharmacodynamic model for propofol-induced ventilatory depression in the non-steady state has not been described. To investigate propofol-induced ventilatory depression in the clinically important range (at and below the metabolic hyperbola while carbon dioxide is accumulating because of drug-induced ventilatory depression), the authors applied indirect effect modeling to Paco2 data at a fraction of inspired carbon dioxide of 0 during and after administration of propofol. METHODS: Ten volunteers underwent determination of their carbon dioxide responsiveness by a rebreathing design. The parameters of a power function were fitted to the end-expiratory carbon dioxide and minute ventilation data. The volunteers then received propofol in a stepwise ascending pattern with use of a target-controlled infusion pump until significant ventilatory depression occurred (end-tidal pressure of carbon dioxide > 65 mmHg and/or imminent apnea). Thereafter, the concentration was reduced to 1 microg/ml. Propofol pharmacokinetics and the Paco2 were determined from frequent arterial blood samples. An indirect response model with Bayesian estimates of the pharmacokinetics and carbon dioxide responsiveness in the absence of drug was used to describe the Paco2 time course. Because propofol reduces oxygen requirements and carbon dioxide production, a correction factor for propofol-induced decreasing of carbon dioxide production was included. RESULTS: The following pharmacodynamic parameters were found to describe the time course of hypercapnia after administration of propofol (population mean and interindividual variability expressed as coefficients of variation): F (gain of the carbon dioxide response), 4.37 +/- 36.7%; ke0, CO2, 0.95 min-1 +/- 59.8%; baseline Paco2, 40.9 mmHg +/- 12.8%; baseline minute ventilation, 6.45 l/min +/- 36.3%; kel, CO2, 0.11 min-1 +/- 34.2%; C50,propofol, 1.33 microg/ml +/- 49.6%; gamma, 1.68 +/- 21.3%. CONCLUSION: Propofol at common clinical concentrations is a potent ventilatory depressant. An indirect response model accurately described the magnitude and time course of propofol-induced ventilatory depression. The indirect response model can be used to optimize propofol administration to reduce the risk of significant ventilatory depression.

Adult↗

Pharmacodynamic interaction between propofol and remifentanil regarding hypnosis, tolerance of laryngoscopy, bispectral index, and electroencephalographic approximate entropy.

BACKGROUND: The purpose of this investigation was to describe the pharmacodynamic interaction between propofol and remifentanil for probability of no response to shaking and shouting, probability of no response to laryngoscopy, Bispectral Index (BIS), and electroencephalographic approximate entropy (AE). METHODS: Twenty healthy volunteers received either propofol or remifentanil alone and then concurrently with a fixed concentration of remifentanil or propofol, respectively, via a target-controlled infusion. Responses to shaking and shouting and to laryngoscopy were assessed multiple times after allowing for plasma effect site equilibration. The raw electroencephalogram and BIS were recorded throughout the study, and AE was calculated off-line. Response surfaces were fit to the clinical response data using logistic regression or hierarchical response models. Response surfaces were also estimated for BIS and AE. Surfaces were visualized using three-dimensional rotations. Model parameters were estimated with NONMEM. RESULTS: Remifentanil alone had no appreciable effect on response to shaking and shouting or response to laryngoscopy. Propofol could ablate both responses. Modest remifentanil concentrations dramatically reduced the concentrations of propofol required to ablate both responses. The hierarchical response surface described the data better than empirical logistic regression. BIS and AE are more sensitive to propofol than to remifentanil. CONCLUSIONS: Remifentanil alone is ineffective at ablating response to stimuli but demonstrates potent synergy with propofol. BIS and AE values corresponding to 95% probability of ablating response are influenced by the combination of propofol and remifentanil to achieve this endpoint, with higher propofol concentrations producing lower values for BIS and AE.

Adult↗

Determination of the pharmacodynamic interaction of propofol and remifentanil during esophagogastroduodenoscopy in children.

BACKGROUND: Propofol is commonly used to anesthetize children undergoing esophagogastroduodenoscopy. Opioids are often used in combination with propofol to provide total intravenous anesthesia. Because both propofol and remifentanil are associated with rapid onset and offset, the combination of these two drugs may be particularly useful for procedures of short duration, including esophagogastroduodenoscopy. The authors previously demonstrated that the median effective concentration (C50) of propofol during esophagogastroduodenoscopy in children is 3.55 microg/ml. The purpose of this study was to describe the pharmacodynamic interaction of remifentanil and propofol when used in combination for esophagogastroduodenoscopy in pediatric patients. METHODS: The authors studied 32 children aged between 3 and 10 yr who were scheduled to undergo esophagogastroduodenoscopy. Propofol was administered via a target-controlled infusion system using the STANPUMP software based on a pediatric pharmacokinetic model. Remifentanil was administered as a constant rate infusion of 25, 50, and 100 ng.kg(-1).min(-1) to each of three study groups, respectively. A sigmoid Emax model was developed to describe the interaction of remifentanil and propofol. RESULTS: There was a positive interaction between remifentanil and propofol when used in combination. The concentration of propofol alone associated with 50% probability of no response was 3.7 microg/ml (SE, 0.4 microg/ml), and this was decreased to 2.8 microg/ml (SE, 0.1 microg/ml) when used in combination with remifentanil. CONCLUSION: A remifentanil infusion of 25 ng.kg(-1).min(-1) reduces the concentration of propofol required for adequate anesthesia for esophagogastroduodenoscopy from 3.7 to 2.8 microg/ml. Increasing the remifentanil infusion yields minimal additional decrease in propofol concentration and may increase the risk of side effects.

Child↗

Spectral entropy as an electroencephalographic measure of anesthetic drug effect: a comparison with bispectral index and processed midlatency auditory evoked response.

BACKGROUND: The authors compared the behavior of two calculations of electroencephalographic spectral entropy, state entropy (SE) and response entropy (RE), with the A-Line ARX Index (AAI) and the Bispectral Index (BIS) and as measures of anesthetic drug effect. They compared the measures for baseline variability, burst suppression, and prediction probability. They also developed pharmacodynamic models relating SE, RE, AAI, and BIS to the calculated propofol effect-site concentration (Ceprop). METHODS: With institutional review board approval, the authors studied 10 patients. All patients received 50 mg/min propofol until either burst suppression greater than 80% or mean arterial pressure less than 50 mmHg was observed. SE, RE, AAI, and BIS were continuously recorded. Ceprop was calculated from the propofol infusion profile. Baseline variability, prediction of burst suppression, prediction probability, and Spearman rank correlation were calculated for SE, RE, AAI, and BIS. The relations between Ceprop and the electroencephalographic measures of drug effect were estimated using nonlinear mixed effect modeling. RESULTS: Baseline variability was lowest when using SE and RE. Burst suppression was most accurately detected by spectral entropy. Prediction probability and individualized Spearman rank correlation were highest for BIS and lowest for SE. Nonlinear mixed effect modeling generated reasonable models relating all four measures to Ceprop. CONCLUSIONS: Compared with BIS and AAI, both SE and RE seem to be useful electroencephalographic measures of anesthetic drug effect, with low baseline variability and accurate burst suppression prediction. The ability of the measures to predict Ceprop was best for BIS.

Adolescent↗

Shock values.

Explore the source record for details and available documents.

Anesthetics, Intravenous↗

Application of Bispectral Index and Narcotrend index to the measurement of the electroencephalographic effects of isoflurane with and without burst suppression.

BACKGROUND: The Narcotrend monitor (MonitorTechnik, Bad Bramstedt, Germany) has recently been introduced as an intraoperative monitor of anesthetic state, based on a classification scheme originally developed for visual assessment of the electroencephalogram. The authors compared the performance of the Narcotrend index (software version 4.0) to the Bispectral Index (BIS, version XP; Aspect Medical Systems, Natick, MA) as electroencephalographic measures of isoflurane drug effect during general anesthesia. METHODS: The authors observed 15 adult patients scheduled to undergo radical prostatectomy with a combined epidural-isoflurane general anesthesia technique. At least 45 min after induction of general anesthesia, during a phase of constant surgical stimulation, end-tidal isoflurane concentrations were varied between 0.5 and 2.0 multiples of minimum alveolar concentration, and the BIS and the Narcotrend index were recorded. The prediction probability (PK) was calculated for the BIS and the Narcotrend index to predict isoflurane effect compartment concentration for each measure. The correlation analysis of the BIS and the Narcotrend index with the isoflurane effect compartment concentration was obtained by pharmacodynamic modeling based on two sigmoidal curves to account for the discontinuity in both indices with the onset of burst suppression. RESULTS: The prediction probabilities were indistinguishable (BIS PK = 0.72 +/- 0.07 (mean +/- SD); range, 0.61-0.84; Narcotrend index PK = 0.72 +/- 0.10; range, 0.51-0.87), as were the correlations between the electroencephalographic measures and isoflurane effect compartment concentrations (BIS R = 0.82 +/- 0.12; Narcotrend index R = 0.85 +/- 0.09). The pharmacodynamic models for the BIS and the Narcotrend index yielded nearly identical results. CONCLUSIONS: The BIS and the Narcotrend index detected the electroencephalographic effects of isoflurane equally. Combining two fractional sigmoid Emax models adequately described the data before and after the onset of burst suppression.

Aged↗

Induction speed is not a determinant of propofol pharmacodynamics.

BACKGROUND: Evidence suggests that the rate at which intravenous anesthetics are infused may influence their plasma-effect site equilibration. The authors used five different rates of propofol administration to test the hypothesis that different sedation endpoints occur at the same effect site propofol concentration, independent of the infusion rate. The authors concurrently evaluated the automated responsiveness monitor (ARM) against other sedation measures and the propofol effect site concentration. METHODS: With Human Studies Committee approval, 18 healthy volunteers received five consecutive target-controlled propofol infusions. During each infusion, the effect site concentration was increased by a rate of 0.1, 0.3, 0.5, 0.7, or 0.9 microg . ml . min. The Bispectral Index and ARM were recorded at frequent intervals. The times of syringe drop and loss and recovery of responsiveness were noted. Pharmacokinetic and pharmacodynamic modeling was performed using NONMEM. RESULTS: When the correct rate of plasma-effect site equilibration was determined for each individual (plasma-effect site equilibration = 0.17 min, time to peak effect = 2.7 min), the effect site concentrations associated with each clinical measure were not affected by the rate of increase of effect site propofol concentration. ARM correlated with all clinical measures of drug effect. Subjects invariably stopped responding to ARM at lower effect site propofol concentrations than those associated with loss of responsiveness. CONCLUSIONS: : Population-based pharmacokinetics, combined with real-time electroencephalographic measures of drug effect, may provide a means to individualize pharmacodynamic modeling during target-controlled drug delivery. ARM seems useful as an automated measure of sedation and may provide the basis for automated monitoring and titration of sedation for a propofol delivery system.

Adolescent↗

Target controlled infusions: targeting the effect site while limiting peak plasma concentration.

BACKGROUND: Target controlled infusion (TCI) systems are available commercially worldwide, except in North America. Existing systems target the plasma drug concentration, which may be less than ideal because the plasma is not the site of drug effect. The commonly accepted existing algorithm to target the site of drug effect results in high plasma concentrations, which may increase the acute hemodynamic effects of intravenous anesthetic drugs. METHODS: A novel mathematical algorithm is proposed for controlling the effect site concentration using a TCI device. The algorithm limits the peak plasma concentration, thereby slowing the onset of anesthetic drug effect but potentially ameliorating side effects. Simulations are used to examine the delay in time to peak effect for fentanyl, alfentanil, sufentanil, remifentanil, and propofol when the peak plasma concentration is limited by the algorithm. RESULTS: The plasma overshoot required of the previously proposed algorithm to control the site of drug effect can be reduced by 60% with only about a 20% delay in the onset of drug effect. CONCLUSIONS: Concerns about the high plasma concentrations that result from targeting the effect site with a TCI device can be addressed by reducing the peak plasma concentration by as much as 60% with only a very modest increase in time to peak effect.

Algorithms↗

Teaching application of clinical pharmacology skills using unusual observations from clozapine overdoses.

Massive drug overdoses provide a unique opportunity to observe human pharmacokinetic data not otherwise ethically available. They can also provide practical examples for teaching thoughtful application of the principles of clinical pharmacology. Following a case of clozapine overdose in which onset of toxicity was delayed by 72 hours, a probable explanation was found in an exploration of three cases with unusual concentration-time profiles and revealed unexpected implications for the management of clozapine overdoses. The authors systematically addressed the possible mechanisms proposed in the literature for an unusual plateau in concentrations observed in three clozapine overdoses. The effects that the most commonly suggested explanations (i.e., delayed absorption and saturated or impaired metabolism) would have on both clozapine and norclozapine concentrations were then modeled using the data available from those three cases to provide an objective illustration for comparison. This exercise was then used as a teaching seminar, leading students through the steps required to reach a logical explanation for the observed delayed toxicity and to consider the implications for therapy. Delayed absorption best predicted the sustained serum clozapine and norclozapine concentrations observed in three cases, and modeling suggests that much of the drug remains in the gut, available for absorption for days following an overdose. As a seminar, the exercise provides students with a practical example of the value of systematically ruling out possible explanations by considering what effects various pharmacokinetic alterations would have on observed data. Absorption following massive clozapine overdose appears fundamentally different from that with conventional dosing. This suggests a potential for delayed or prolonged toxicity, extending well beyond the time frame predicted by its half-life, unless aggressive and sustained efforts are applied to remove clozapine from the gut. Data from drug overdoses provide opportunities to explore unusual aspects of pharmacokinetics, better understand future overdoses of the same agent, and present excellent material for teaching. A seminar illustrating the role that thoughtful application of pharmacologic principles had in addressing this case is now used to introduce the clinical aspects of pharmacology to students at our institutions.

Adult↗

Mathematical analysis of a pharmacodynamic model without plasma concentrations to extend its applicability.

Using a mathematical approach, we analyzed the behavior of the PD model originally described by Bragg et al. The effect was dose-dependent modified until a maximum value (E(max)) was reached. Further increments in dose prolonged the E(max), but the recovery phase did not increase beyond a calculable asymptope. In the absence of plasma concentrations, it was impossible to distinguish the rate of plasma equilibration with the effect compartment (k(e0)) from the rate of drug elimination (k(e1)). Variations on the sigmoidicity affected both the onset and offset of drug effect. Sigmoidicity and the slowest rate constant had identical effects on the spontaneous reversion of the effect, as judged by the recovery index. The IR(50), the index of potency, merely shifted the dose-response relationship to the left or right. Changes in IR(50) were compensated for by making the same proportional changes in dose.

Blood↗

Correlation of approximate entropy, bispectral index, and spectral edge frequency 95 (SEF95) with clinical signs of "anesthetic depth" during coadministration of propofol and remifentanil.

BACKGROUND: Several studies relating electroencephalogram parameter values to clinical endpoints using a single (mostly hypnotic) drug at relatively low levels of central nervous system depression (sedation) have been published. However, the usefulness of a parameter derived from the electroencephalogram for clinical anesthesia largely depends on its ability to predict the response to stimuli of different intensity or painfulness under a combination of a hypnotic and an (opioid) analgesic. This study was designed to evaluate the predictive performance of spectral edge frequency 95 (SEF95), BIS, and approximate entropy for the response to increasingly intense stimuli under different concentrations of both propofol and remifentanil in the therapeutic range. METHODS: Ten healthy male and ten healthy female volunteers were studied during coadministration of propofol and remifentanil. After having maintained a specific target concentration for 10 min, the depth of sedation-anesthesia was assessed using the responsiveness component of the Observer's Assessment of Alertness/Sedation (OAA/S) rating scale, which was modified by adding insertion of a laryngeal mask and laryngoscopy. The electroencephalogram derived parameters approximate entropy, bispectral index, and SEF95 were recorded just before sedation level was assessed. RESULTS: The prediction probability values for approximate entropy were slightly, but not significantly, better than those for bispectral index, SEF95, and the combination of drug concentrations. A much lower prediction ability was observed for tolerance of airway manipulation than for hypnotic endpoints. CONCLUSION: Approximate entropy revealed informations on hypnotic and analgesic endpoints using coadministration of propofol and remifentanil comparable to bispectral index, SEF95, and the combination of drug concentrations.

Adult↗

Cephalad movement of morphine and fentanyl in humans after intrathecal injection.

BACKGROUND: Despite decades of use, controversy remains regarding the extent and time course of cephalad spread of opioids in cerebrospinal fluid (CSF) after intrathecal injection. The purpose of this study was to examine differences between two often used opioids, morphine and fentanyl, in distribution in the CSF after intrathecal injection. METHODS: Eight healthy volunteers received intrathecal injection of morphine (50 microg) plus fentanyl (50 microg) at a lower lumbar interspace. CSF was sampled through a needle in an upper lumbar interspace for 60-120 min. At the end of this time, a sample was taken from the lower lumbar needle, and both needles were withdrawn. CSF volume was determined by magnetic resonance imaging. Pharmacokinetic modeling was performed with NONMEM. RESULTS: Morphine and fentanyl peaked in CSF at the cephalad needle at similar times (41 +/- 13 min for fentanyl, 57 +/- 12 min for morphine). The ratio of morphine to fentanyl in CSF at the cephalad needle increased with time, surpassing 2:1 by 36 min and 4:1 by 103 min. CSF concentrations did not correlate with weight, height, or lumbosacral CSF volume. The concentrations of morphine and fentanyl at both sampling sites were well described by a simple pharmacokinetic model. The individual model parameters did not correlate with the distance between the needles, CSF volume, patient height, or patient weight. CONCLUSIONS: Fentanyl is cleared more rapidly from CSF than morphine, although their initial distribution in the first hour after injection does not differ greatly. The pharmacokinetic model demonstrates that mixing is the primary determinant of early concentrations and is highly variable among individuals.

Adolescent↗

Using the time of maximum effect site concentration to combine pharmacokinetics and pharmacodynamics.

BACKGROUND: To simulate the time course of drug effect, it is sometimes necessary to combine the pharmacodynamic parameters from an integrated pharmacodynamic-pharmacodynamic study (e.g., volumes, clearances, k(e0) [the effect site equilibration rate constant], C(50) [the steady state plasma concentration associated with 50% maximum effect], and the Hill coefficient) with pharmacokinetic parameters from a different study (e.g., a study examining a different age group or sampling over longer periods of time). Pharmacokinetic-pharmacodynamic parameters form an interlocked vector that describes the relationship between input (dose) and output (effect). Unintended consequences may result if individual elements of this vector (e.g., k(e0)) are combined with pharmacokinetic parameters from a different study. The authors propose an alternative methodology to rationally combine the results of separate pharmacokinetic and pharmacodynamic studies, based on t(peak), the time of peak effect after bolus injection. METHODS: The naive approach to combining separate pharmacokinetic and pharmacodynamic studies is to simply take the k(e0) from the pharmacodynamic study and apply it naively to the pharmacokinetic study of interest. In the t(peak) approach, k(e0) is recalculated using the pharmacokinetics of interest to yield the correct time of peak effect. The authors proposed that the t(peak) method would yield better predictions of the time course of drug effect than the naive approach. They tested this hypothesis in three simulations: thiopental, remifentanil, and propofol. RESULTS: In each set of simulations, the t(peak) method better approximated the postulated "true" time course of drug effect than the naive method. CONCLUSIONS: T(peak) is a useful pharmacodynamic parameter and can be used to link separate pharmacokinetic and pharmacodynamic studies. This addresses a common difficulty in clinical pharmacology simulation and control problems, where there is usually a wide choice of pharmacokinetic models but only one or two published pharmacokinetic-pharmacodynamic models. The results will be immediately applicable to target-controlled anesthetic infusion systems, where linkage of separate pharmacokinetic and pharmacodynamic parameters into a single model is inherent in several target-controlled infusion designs.

Aging↗