PubMed Health⌕ Search

Biomedical subjects

Steven Richard Kitchen

Publications and source records attributed to Steven Richard Kitchen.

2 recordsLinked to original sources

Quasi-achromatic laser Doppler anemometry systems based on a diffractive beam splitter.

We propose a new beam-splitter system that makes it possible to use nonstabilized laser diodes for laser Doppler anemometry (LDA) systems by making the system wavelength independent. The beam splitter consists of two linear diffraction gratings that produce two parallel beams with a beam spacing that is wavelength dependent. This ensures passive wavelength compensation for the fringe spacing in the measurement volume. One can choose the distance between the two parallel beams by changing the distance between the two gratings, whereas the distance to the measurement volume can be designed by choice of a condensing lens with the proper focal length. This means that the system can be designed to have a desired fringe spacing in the measurement volume. The gratings are implemented as surface-relief holograms in photoresist, which makes it possible to mass produce the beam-splitter system at low cost through replication of the structure. The method for passive wavelength compensation for the fringe spacing is demonstrated both theoretically and experimentally.

Journal Article↗

Holographic common-path interferometer for angular displacement measurements with spatial phase stepping and extended measurement range.

A novel technique for extending the unambiguous measurement range for differential measurements of angular deflections is presented. The technique utilizes a common-path interferometer that simultaneously probes the out-of-plane displacement of three points on the object surface. The system is based on a single laser diode, and all the optical functions of the system are implemented in a dedicated holographic optical element (HOE). The HOE automatically provides spatially phase-stepped interference signals for real-time phase measurement. It is therefore not necessary to employ any polarizing optics or active elements to introduce the phase stepping. The common-path scheme combined with the HOE provides a system that is inherently stable, since the HOE operates as both transmitter and receiver in the system. The system is compact, is robust, and has the potential for being mass-produced at a low cost and is thus well suited for industrial use, such as in commercial vibrometers. The technique is demonstrated in a system for measuring angular deflections of a plane mirror. The technique, however, is not restricted to this use alone and can easily be configured to probe other types of surface displacements, e.g., the deflection of a diaphragm. In the present configuration, the system can measure angular deflections with a sensitivity of 2.5 x 10(-7) rad over a measurement range that is approximately 3.5 x 10(-3) rad, i.e., a dynamic range of approximately 1:14,000. Furthermore, the system can easily be reconfigured for a desired angular sensitivity and measurement range.

Journal Article↗