PubMed Health⌕ Search

Biomedical subjects

Steven T Haworth

Publications and source records attributed to Steven T Haworth.

4 recordsLinked to original sources

Effect of chronic hyperoxic exposure on duroquinone reduction in adult rat lungs.

NAD(P)H:quinone oxidoreductase 1 (NQO1) plays a dominant role in the reduction of the quinone compound 2,3,5,6-tetramethyl-1,4-benzoquinone (duroquinone, DQ) to durohydroquinone (DQH2) on passage through the rat lung. Exposure of adult rats to 85% O2 for > or =7 days stimulates adaptation to the otherwise lethal effects of >95% O2. The objective of this study was to examine whether exposure of adult rats to hyperoxia affected lung NQO1 activity as measured by the rate of DQ reduction on passage through the lung. We measured DQH2 appearance in the venous effluent during DQ infusion at different concentrations into the pulmonary artery of isolated perfused lungs from rats exposed to room air or to 85% O2. We also evaluated the effect of hyperoxia on vascular transit time distribution and measured NQO1 activity and protein in lung homogenate. The results demonstrate that exposure to 85% O2 for 21 days increases lung capacity to reduce DQ to DQH2 and that NQO1 is the dominant DQ reductase in normoxic and hyperoxic lungs. Kinetic analysis revealed that 21-day hyperoxia exposure increased the maximum rate of pulmonary DQ reduction, Vmax, and the apparent Michaelis-Menten constant for DQ reduction, Kma. The increase in Vmax suggests a hyperoxia-induced increase in NQO1 activity of lung cells accessible to DQ from the vascular region, consistent qualitatively but not quantitatively with an increase in lung homogenate NQO1 activity in 21-day hyperoxic lungs. The increase in Kma could be accounted for by approximately 40% increase in vascular transit time heterogeneity in 21-day hyperoxic lungs.

Animals↗

Microfocal X-ray computed tomography post-processing operations for optimizing reconstruction volumes of stented arteries during 3D computational fluid dynamics modeling.

Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to generate geometrically accurate flow domains within the localized region of a stent several weeks after implantation. Microfocal X-ray CT reconstruction volumes were subjected to an automated program to perform arterial thresholding, spatial orientation, and surface smoothing of stented and unstented rabbit iliac arteries several weeks after antegrade implantation. A transfer function was obtained for the current post-processing methodology containing reconstructed 16 mm stents implanted into rabbit iliac arteries for up to 21 days after implantation and resolved at circumferential and axial resolutions of 32 and 50 microm, respectively. The results indicate that the techniques presented are sufficient to resolve distributions of WSS with 80% accuracy in segments containing 16 surface perturbations over a 16 mm stented region. These methods will be used to test the hypothesis that reductions in normalized wall shear stress (WSS) and increases in the spatial disparity of WSS immediately after stent implantation may spatially correlate with the temporal development of NH within the stented region.

Angiography↗

What leads to different mediators of alkalosis-induced vasodilation in isolated and in situ pulmonary vessels?

We previously found that nitric oxide synthase (NOS) inhibition fully blocked alkalosis-induced relaxation of piglet pulmonary artery and vein rings. In contrast, NOS inhibition alone had no effect on alkalosis-induced pulmonary vasodilation in isolated piglet lungs. This study sought to identify factors contributing to the discordance between isolated and in situ pulmonary vessels. The roles of pressor stimulus (hypoxia vs. the thromboxane mimetic U-46619), perfusate composition (blood vs. physiological salt solution), and flow were assessed. Effects of NOS inhibition on alkalosis-induced dilation were also directly compared in 150-350-microm-diameter cannulated arteries and 150-900-microm-diameter, angiographically visualized, in situ arteries. Finally, effects of NOS inhibition on alkalosis-induced vasodilation were measured in intact piglets. NOS inhibition with N(omega)-nitro-L-arginine fully abolished alkalosis-induced vasodilation in all cannulated arteries but failed to alter alkalosis-induced vasodilation in intact lungs. The results indicate that investigation of other factors, such as perivascular tissue (e.g., adventitia and parenchyma) and remote signaling pathways, will need to be carried out to reconcile this discordance between isolated and in situ arteries.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗

Influence of gravity on radiographic contrast material-based measurements of regional blood flow distribution.

RATIONALE AND OBJECTIVES: Radiographic measurement of regional blood flow distribution in the lungs is potentially biased because the contrast material used to track flow is denser than blood. The authors performed this study to evaluate the effect of gravity on flow estimates by using an experimental test phantom and numeric simulations. MATERIALS AND METHODS: Cross-sectionally uniform boluses of radiopaque contrast material were delivered at the upstream end of a horizontal inlet tube connected to a downstream axisymmetric bifuration attached to collecting tubing spirals. The phantom was imaged by using both planar angiography and dynamic multi-detector row computed tomography (CT) during the passage of the bolus through the phantom. The images were analyzed to determine the relative amounts of contrast material traveling through the top and bottom branches of the bifurcation by using varying Reynolds numbers and ratios of inlet tube volume to bolus volume. Numeric simulations of flow within a straight channeL with use of a dispersion operator intended to simulate settling of the bolus due to gravity, were performed under conditions representative of those in the experiments. RESULTS: When the plane of the bifurcation was vertical and actual flow through the two branches was equal, the fraction of contrast material passing through the downward-directed branch increased with decreasing Reynolds number and increasing inlet tube-bolus volume ratio. This occurred in both the experiments and the simulations. CONCLUSION: Because in the circulation Reynolds number decreases and pathway length increases with decreasing vessel diameter, the accuracy of regional flow measurements obtained with angiography or CT within the lungs may be limited by density differences between contrast material and blood.

Angiography↗