PubMed Health⌕ Search

Biomedical subjects

Steven W Graves

Publications and source records attributed to Steven W Graves.

6 recordsLinked to original sources

Alpha4beta1 integrin affinity changes govern cell adhesion.

Integrin alpha4beta1 is a receptor for vascular cell adhesion molecule-1 and fibronectin. It is important in lymphopoiesis, inflammatory recruitment of leukocytes, and other situations that require cell adhesion to the vascular endothelium. The avidity of the cells expressing alpha4beta1 integrin can be rapidly changed by chemokines and chemoattractants. Different mechanisms, including changes in the number of interacting molecules due to the alteration of the receptor topology or changes in the affinity of the individual bonds, have been proposed to explain the nature of these fast changes in avidity. Recently, we described a fluorescent LDV-containing small molecule, which we used to monitor the affinity changes on live cells in real time (Chigaev, A., Blenc, A. M., Braaten, J. V., Kumaraswamy, N., Kepley, C. L., Andrews, R. P., Oliver, J. M., Edwards, B. S., Prossnitz, E. R., Larson, R. S. et al. (2001) J. Biol. Chem. 276, 48670-48678). Here we show that the affinity of the small molecule probe as well as the native ligand vascular cell adhesion molecule-1 varies in parallel when the integrin is modulated with divalent cations and that the affinity modulation leads to the changes in cell avidity. Using formyl peptide receptor-transfected U937 cells, we further show that the time course of avidity changes in response to the receptor activation coincides with the time course of the affinity changes. Taken together, these data are consistent with the idea that affinity regulation is a major factor that governs the avidity of cell adhesion mediated by the alpha4 integrin.

Animals↗

Advantages and limitations of coupling isotachophoresis and comprehensive isotachophoresis-capillary electrophoresis to time-of-flight mass spectrometry.

Capillary isotachophoresis (ITP) and comprehensive isotachophoresis-capillary electrophoresis (ITP-CE) were successfully coupled to electrospray ionization (ESI) orthogonal acceleration time-of-flight mass spectrometry (TOF-MS) using angiotensin peptides as model analytes. The utility of ITP-TOF-MS and ITP-CE-TOF-MS for the analysis of samples containing analyte amounts sufficient to form flat-top ITP zones (30 microM) as well as for samples with trace analyte amounts (0.3 microM) was studied. Separations were performed in 150 microm internal diameter (I.D.) capillaries for the ITP experiments, and in 200 microm I.D. (ITP) and 50 microm I.D. (CE) capillaries for ITP-CE experiments. The fused-silica columns were coated with poly(vinyl alcohol) to suppress electroosmotic flow that can disrupt ITP zone profiles. The sample loading capacity in both ITP and comprehensive ITP-CE was greatly enhanced (up to 10 microl) compared with typical nanoliter-sized injection volumes in CE. It was concluded that ITP-TOF-MS alone was adequate for the separation and detection of high concentration samples. The outcome was different at lower analyte concentrations where mixed zones or very sharp peaks formed. With formation of mixed zones, ion suppression and discrimination could occur, complicating quantitative determination of the analytes. This problem was effectively overcome by inserting a CE capillary between the ITP and TOF-MS. In such an arrangement, samples were preconcentrated in the high load WTP capillary and then injected into a CE capillary where they were separated into non-overlapping peaks prior to their detection by TOF-MS. The advantage of this comprehensive arrangement, which we have described previously, is that there is no need to discard portions of the sample in order to avoid overloading of the CE capillary. The whole sample is analyzed by multiple injections from ITP to CE. Thus, this method can be used for the analysis of complex samples with wide ranges of component concentrations.

Electrophoresis↗

Changes in the isoforms of the sodium pump in the placenta and myometrium of women in labor.

OBJECTIVE: We determined whether changes in sodium pump isoform abundance accompanied active human labor. STUDY DESIGN: Specimens of placenta, amniochorion, and myometrium were collected from women in active spontaneous labor and from those not in labor. The abundance of the three sodium pump alpha-isoforms was determined by Western blot analysis. RESULTS: Levels of the alpha1 and alpha2 isoforms were comparable in the three tissues for women in labor and not in labor. However, alpha3 isoform abundance in placenta and myometrium (but not amniochorion) was significantly decreased in women in active labor compared with women not in labor (sodium pump alpha3 in placenta: no labor 91.2 +/- 27.6 vs labor 46.9 +/- 3.6 density units, P =.002. Sodium pump alpha3 in myometrium: no labor 52.3 +/- 7.7 vs labor 19.8 +/- 1.6 density units, P =.0002). CONCLUSION: Because reductions in sodium pump number can result in hormone release from secretory tissues and in contraction of muscle, this suggests that the sodium pump may play a significant role in the initiation or maintenance of human labor.

Adult↗

Determination of catecholamines and metanephrines in urine by capillary electrophoresis-electrospray ionization-time-of-flight mass spectrometry.

A method successfully coupling capillary electrophoretic separation to time-of-flight mass spectrometric (TOFMS) detection for the simultaneous analysis of catecholamines (dopamine, norepinephrine, and epinephrine) and their O-methoxylated metabolites (3-methoxytyramine, normetanephrine, and metanephrine) is described. The inner capillary wall was coated with polyvinyl alcohol in order to obtain baseline resolution of catecholamines and metanephrines and to ensure reproducibility without extensive restorative washing of the capillary. Using electrokinetic injection, detection limits of 0.3 microM for dopamine and norepinephrine, 0.2 microM for 3-methoxytyramine and normetanephrine, and 0.1 microM for epinephrine and metanephrine were achieved with standard solutions. The usefulness of this approach was demonstrated by applying the developed method to the analysis of a spot collection of human urine from a healthy volunteer. The catecholamines and metanephrines were removed from the urine samples and preconcentrated by simultaneous SPE on cation-exchange sorbents. The recoveries of all analytes, with the exception of epinephrine (75%), were over 80%. Catecholamines and metanephrines in the urine samples were quantitated using 3,4-dihydroxybenzylamine as an internal standard. Submicromolar concentrations, consistent with the catecholamine and metanephrine levels reported for normal human urine, were detected.

Catecholamines↗

Nozzle design parameters and their effects on rapid sample delivery in flow cytometry.

BACKGROUND: Rapid kinetic and high throughput flow cytometry are emerging as valuable tools in biotechnology research applications ranging from mechanistic analysis of molecular assemblies to high throughput screening. Many of these new applications have been made possible by improved sample delivery capabilities, focusing increased attention on fluidic issues associated with rapid sample delivery. METHODS: Using basic fluidic premises, we derived a model that predicted the effect of nozzle parameters during rapid sample delivery. We tested the model using the rapid mix flow cytometer and modifications were made to the equipment to optimize performance. RESULTS: The model predicted that shorter nozzles with wide exit orifices decrease the delay before initial particle analysis and the fluidic stabilization time. Experimental results confirmed this prediction and model-based modifications allowed analysis of particles within 55 ms or 600 ms after mixing, with or without electronic gating, respectively. CONCLUSIONS: The model along with modifications to commercial equipment will allow rapid mix flow cytometry to analyze reactions in time frames threefold shorter than previously possible. The model allows for nozzle design predictions that should allow for analysis in the millisecond time frame. Furthermore, these findings are general for all rapid delivery applications, including high throughput flow cytometry.

Automation↗

Flow cytometric analysis of ligand-receptor interactions and molecular assemblies.

Flow cytometers make homogeneous real-time measurements of ligand-receptor interactions and, simultaneously, the physiological responses of cells. Their multiparameter capabilities are also useful in resolving multicomponent assemblies or in developing multiplexed assays. Recent advances suggest that these approaches can be extended in several important ways. Sample delivery in the millisecond time domain is applicable to the analysis of complex binding kinetics and reaction mechanisms. The homogeneous discrimination of free components and particle-based assemblies can be extended into the micromolar concentration range. Measurements can be made of molecular assemblies among proteins, DNA, RNA, lipids, and carbohydrates on beads. The topography and assembly of components within cells can be evaluated with resonance energy transfer. Temperature dependence can be evaluated with Peltier temperature control. Many assembly endpoints can be assessed through new tools for high-throughput flow cytometry using plate-based assay formats and small volume samples.

Animals↗