PubMed Health⌕ Search

Biomedical subjects

Stig A Svensson

Publications and source records attributed to Stig A Svensson.

2 recordsLinked to original sources

Reflection photoelasticity: a new method for studies of clinical mechanics in prosthetic dentistry.

OBJECTIVES: This research was conducted to demonstrate the effectiveness of reflective photoelasticity as an in vivo technique for monitoring the strain/stress distribution in prosthetic devices during function. METHODS: Seven subjects were selected for this study and divided into three groups according to the design of the prostheses. The buccal surfaces of the experimental prostheses were coated with a birefringent resin 2mm thick. Using a reflection polariscope, fringe patterns were documented on video tape during standardized in vivo loadings. Strain and stress levels (gamma(max) and tau(max)) were calculated from isochromatic fringe order determinations. The intra-observer variability in counting fringe orders and the accuracy level of reflective photoelasticity as compared to strain gauge results were also studied. The strain results of in vivo loading of the prostheses were analyzed with ANOVA and Scheffés tests. The intra-observer variability was analyzed with the Friedman nonparametric test. Comparisons of photoelastic data and strain gauges were tested with Pearson's correlation. RESULTS: Coated areas accessible to normally incident light, produced comprehensive maps of strain distribution. Significant differences were found in the in vivo gamma(max) values for the prostheses designs (p<0.05). The test for intra-observer variability showed that no significant differences occurred in counting fringe orders. Strain values obtained with reflective photoelasticity showed a high correlation r=0.98 and 0.99) with values obtained at the same areas using strain gauges. SIGNIFICANCE: Reflective photoelasticity is a valid, reliable and accurate technique to be used for in vivo studies on the biomechanical behavior of prosthetic devices.

Aged↗

A novel sensor for bite force determinations.

OBJECTIVES: The clinical usefulness, accuracy and precision of a novel bite force sensor based on force sensing resistors were tested in six subjects wearing maxillary removable partial dentures retained by conical crowns. METHODS: The surfaces of the sensor were manufactured in a silicone material that had mechanical properties similar to those of tough foodstuffs. In two separate series of standardized bite force tests, submaximum force levels were recorded with the sensor and with a strain gaged bite fork. Subjects were assisted in the loading tests with visual feedback instrumentation. Reliability estimates for the bite force sensor were calculated in order to show their reproducibility. Strain gages attached to the prostheses were used to determine the pattern of force distribution during loading tests. The bite force results obtained with the new bite force sensor and with the bite fork were analyzed with ANOVA and Scheffés tests. The strain patterns registered with strain gages were analyzed with F-test. RESULTS: The bite force sensor and the bite fork transducer showed no statistically significant differences in respect of intra-individual bite force levels (range 50-300N). The bite forces registered with the new sensor were dependent on the loading position (p<0.05), sex (p<0.05) and test subject (p<0.05). The reliability of the new sensor for submaximum bite forces was calculated to be 93%. Strain gage results showed that the new sensor generated strain patterns of less variance (p<0.05) than the bite fork and therefore allowed for higher precision during biting tests. SIGNIFICANCE: The presented instrument has such clinical merits, as to favor its use in experimental clinical studies on the biomechanics of prosthetic appliances.

Aged↗