PubMed Health⌕ Search

Biomedical subjects

Stig Holtås

Publications and source records attributed to Stig Holtås.

3 recordsLinked to original sources

Assessment of contractile and noncontractile components in human skeletal muscle by magnetic resonance imaging.

A magnetic resonance imaging (MRI) technique for the assessment of contractile and noncontractile components of human skeletal muscle is described, and the inter-rater and intra-rater test-retest reliability for repeated measurements from the same MR image are examined. Twenty cross-sectional MR images from the right lower leg were obtained from 30 healthy young men and women (mean age 24.1 years, SD 3.3). The anatomical cross-sectional area (aCSA; cm2), the cross-sectional area of noncontractile components (Noncon; cm2), the contractile cross-sectional area (cCSA = aCSA minus Noncon; cm2), and the relative amount of Noncon (%), of the ankle dorsiflexor muscle compartment were determined for each slice using a computer-based image analysis system. Reliability for repeated measurements of the slice with the largest aCSA for the 30 subjects was analyzed by two raters on two different occasions. Inter-rater reliability on both occasions, assessed by the intraclass correlation coefficient (ICC), was excellent for cCSA (ICC3.1 = 0.99) and Noncon (ICC(3.1) > 0.82). Intra-rater (between occasions) reliability was excellent for the two raters for measurements of cCSA (ICC1.1 = 0.99) and Noncon (ICC1.1 > 0.94). Bland and Altman analyses did not identify any clinically relevant bias in the measurements. Method errors were acceptable: within subjects coefficients of variation (CV) was less than 1.8% for cCSA and less than 16.3% for Noncon. It is concluded that repeated measurements of contractile and noncontractile components of the ankle dorsiflexor muscle compartment, obtained from the same MR image, are highly reliable.

Adult↗

Combined diffusion weighting and CSF suppression in functional MRI.

In this study, EPI pulse sequences with diffusion weighting for reduction of contributions from large vessels and inversion pulses in order to minimize the effects of CSF pulsations and CSF partial volume effects were developed for BOLD contrast investigations in functional MR imaging. One inversion recovery echo-planar imaging (IR-EPI) pulse sequence and one IR-EPI with additional diffusion weighting (DW-IR-EPI) were developed and compared to a standard gradient-echo EPI sequence in a cortical stimulation experiment in nine healthy volunteers. Stimulation of motor cortex was performed using a semi-complex finger-tapping paradigm in seven periods of alternating rest and stimulation. Comparison between the three pulse sequences was made by measuring the activated volume in each subject, as well as by calculating the relative signal increase during stimulation. Due to different baseline signal-to-noise levels in the images generated by the three pulse sequences, artificial noise was added so that the comparative investigation could be performed independently of the noise level. The activated volume was 128 +/- 73 pixels (mean +/- SD) using the standard EPI pulse sequence, 31 +/- 12 pixels using IR-EPI and 15 +/- 13 pixels when DW-IR-EPI was employed. The relative signal increase was 5.7 +/- 1.1% using standard EPI, 11.5 +/- 3.1% using IR-EPI and 9.9 +/- 2.4% using DW-IR-EPI. The activated volume obtained with the addition of extra noise, i.e. at equal S/N, was 70 +/- 50 pixels using the standard EPI, and when using IR-EPI, the activated volume was 28 +/- 13 pixels. At equal S/N, the signal increase was 7.3 +/- 1.4% using standard EPI and 12.0 +/- 3.6% using IR-EPI. In BOLD contrast imaging, a combination of diffusion weighting and inversion recovery appeared to reduce false activation caused by CSF pulsation and blood flow in large vessels.

Adult↗