Publications and source records attributed to Stijn Vandenberghe.

14 recordsLinked to original sources

The PediaFlow pediatric ventricular assist device.

The very limited options available to treat ventricular failure in patients with congenital and acquired heart diseases have motivated the development of a pediatric ventricular assist device (VAD). Our effort involves a consortium consisting of the University of Pittsburgh, Carnegie Mellon University, Children's Hospital of Pittsburgh, World Heart Corporation, and LaunchPoint Technologies, LLC. The overall aim of our program is to develop a highly reliable, biocompatible VAD for chronic support (6 months) of the unique and high-risk population of children between 3 kg and 15 kg (patients from birth to 2 years of age). The innovative pediatric VAD we are developing (PediaFlow) is based on a miniature mixed-flow turbodynamic pump featuring magnetic levitation, with the design goal being to assure minimal blood trauma and risk of thrombosis. This article discusses the limitations of current pediatric cardiac assist treatment options and the work to date by our consortium toward the development of a pediatric VAD.

Biocompatible Materials↗

Towards the development of a pediatric ventricular assist device.

The very limited options available to treat ventricular failure in children with congenital and acquired heart diseases have motivated the development of a pediatric ventricular assist device at the University of Pittsburgh (UoP) and University of Pittsburgh Medical Center (UPMC). Our effort involves a consortium consisting of UoP, Children's Hospital of Pittsburgh (CHP), Carnegie Mellon University, World Heart Corporation, and LaunchPoint Technologies, Inc. The overall aim of our program is to develop a highly reliable, biocompatible ventricular assist device (VAD) for chronic support (6 months) of the unique and high-risk population of children between 3 and 15 kg (patients from birth to 2 years of age). The innovative pediatric ventricular assist device we are developing is based on a miniature mixed flow turbodynamic pump featuring magnetic levitation, to assure minimal blood trauma and risk of thrombosis. This review article discusses the limitations of current pediatric cardiac assist treatment options and the work to date by our consortium toward the development of a pediatric VAD.

Biocompatible Materials↗

Accuracy of 4 different algorithms for the analysis of tomographic radionuclide ventriculography using a physical, dynamic 4-chamber cardiac phantom.

UNLABELLED: Various automatic algorithms are now being developed to calculate left ventricular (LV) and right ventricular (RV) ejection fraction from tomographic radionuclide ventriculography. We tested the performance of 4 of these algorithms in estimating LV and RV volume and ejection fraction using a dynamic 4-chamber cardiac phantom. METHODS: We developed a realistic physical, dynamic 4-chamber cardiac phantom and acquired 25 tomographic radionuclide ventriculography images within a wide range of end-diastolic volumes, end-systolic volumes, and stroke volumes. We assessed the ability of 4 algorithms (QBS, QUBE, 4D-MSPECT, and BP-SPECT) to calculate LV and RV volume and ejection fraction. RESULTS: For the left ventricle, the correlations between reference and estimated volumes (0.93, 0.93, 0.96, and 0.93 for QBS, QUBE, 4D-MSPECT, and BP-SPECT, respectively; all with P < 0.001) and ejection fractions (0.90, 0.93, 0.88, and 0.92, respectively; all with P < 0.001) were good, although all algorithms underestimated the volumes (mean difference [+/-2 SDs] from Bland-Altman analysis: -39.83 +/- 43.12 mL, -33.39 +/- 38.12 mL, -33.29 +/- 40.70 mL, and -16.61 +/- 39.64 mL, respectively). The underestimation by QBS, QUBE, and 4D-MSPECT was greater for higher volumes. QBS, QUBE, and BP-SPECT could also be tested for the right ventricle. Correlations were good for the volumes (0.93, 0.95, and 0.97 for QBS, QUBE, and BP-SPECT, respectively; all with P < 0.001). In terms of absolute volume estimation, the mean differences (+/-2 SDs) from Bland-Altman analysis were -41.28 +/- 43.66 mL, 11.13 +/- 49.26 mL, and -13.11 +/- 28.20 mL, respectively. Calculation of RV ejection fraction correlated well with true values (0.84, 0.92, and 0.94, respectively; all with P < 0.001), although an overestimation was seen for higher ejection fractions. CONCLUSION: Calculation of LV and RV ejection fraction based on tomographic radionuclide ventriculography was accurate for all tested algorithms. All algorithms underestimated LV volume; estimation of RV volume seemed more difficult, with different results for each algorithm. The more irregular shape and inclusion of a relatively hypokinetic RV outflow tract in the right ventricle seemed to cause the greater difficulty with delineation of the right ventricle, compared with the left ventricle.

Algorithms↗

Accuracy of commercially available processing algorithms for planar radionuclide ventriculography using data for a dynamic left ventricular phantom.

BACKGROUND: Automatic and semi-automatic algorithms to calculate ejection fraction (EF) from planar radionuclide ventriculography (PRV) have been used for many years in nuclear medicine. Validation of these algorithms is scarce and often performed on outdated versions of the software. Nevertheless, clinical trials where PRV is being used as the 'gold standard' for EF are numerous. Because of the importance attributed to the EF calculated by these programs, the accuracy of the resulting EF was assessed with a dynamic left ventricular physical phantom. METHODS: A dynamic left ventricular phantom was used to simulate 21 combinations of various ejection fractions (7-66%) and end diastolic volumes (27-290 ml). For each combination, a planar radionuclide ventriculograph was acquired, converted to an interfile format and transferred into processing stations with 10 different contemporaneously available commercial algorithms. The gold standard was the 'real' EF of the phantom, derived from the exact volume of the ventricle in end diastolic and end systolic position. Correlation and Bland-Altman analysis was performed between the real EF and the calculated EF. RESULTS: The correlation for all data was excellent (r=0.98), the mean difference was very acceptable (0.98%). Nevertheless, Bland-Altman analysis showed a significant trend in the difference between real and calculated EF, with a growing underestimation for higher ranges of EF, due to an overestimation of background in larger volumes compared to smaller ones. CONCLUSION: The determination of EF from PRV, calculated with commercially available algorithms, correlates closely to the real EF of a dynamic left ventricular phantom. This phantom can be used in the development and validation of algorithms for PRV studies, in software audits and in quality assurance procedures.

Algorithms↗

The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump.

BACKGROUND: Ventricular assist devices are gaining ground in the therapeutic treatment of chronic heart failure. These devices are sometimes used as a bridge to recovery by unloading the left ventricle (LV) and restoring its function. It is therefore important to preserve the heart muscle and apply less invasive implantation methods. METHODS: In this study ventricular unloading was achieved in 7 healthy sheep with a rotary blood pump at different pump flow levels. Ventricular cannulation via the left atrium (LA) and through the mitral valve was compared to atrial cannulation. The unloading of the heart was assessed with LV pressure-volume loops, derived energetic parameters, and an estimate of LV wall stress. RESULTS: No significant difference between the cannulations was found for any flow or pressure. LA cannulation, however, resulted in significantly lower stroke volumes and stroke work for all pump flow levels. Irrespective of cannulation site, LV volumes and energetic parameters showed a significant decrease with increasing pump flow. CONCLUSION: LV assist with a rotary blood pump can provide sufficient unloading with atrial cannulation.

Animals↗

In vitro assessment of the unloading and perfusion capacities of the PUCA II and the IABP.

The PUCA II pump is a minimally invasive intra-arterial left ventricular assist device that can be used as an alternative for the intra-aortic balloon pump (IABP). In this study, we assessed the cardiac unloading and organ perfusion capacities of both PUCA II and IABP in an in vitro set up, consisting of a heart simulator and a silicone arterial tree, mimicking anatomical geometry and flow distribution. The IABP was positioned in the descending aorta, while the PUCA II was tested both in 'trans-aortic' and 'abdominal' positions. All devices were driven by the same Arrow AutoCat IABP driver at different pump rates. Apart from flow, arterial pressure and pulse pressure, we also calculated haemodynamic indices for myocardial oxygen supply and demand. The 'abdominal' PUCA II assist and the IABP both provide mild unloading of the heart, and a limited improvement of arterial pressure and flow. The 'trans-aortic' PUCA II assist greatly enhances flow and pressure, but does not unload the heart properly in the tested configuration.

Animals↗

Unloading effect of a rotary blood pump assessed by mathematical modeling.

Due to the increased appeal of rotary blood pumps for long-term cardiac assist, we conducted a study of their capacity to unload the left ventricle (LV). We used a validated mathematical model of the cardiovascular system and implemented the pump characteristics of an investigational microdiagonal pump (Medos). The influence of the pump on systemic hemodynamics, LV energetic parameters, and wall stress was evaluated in continuous and synchronous pulsatile modes of operation. For the continuous mode simulations, the influence of heart rate, LV contractility, and pump speed was assessed in a parametric study. For the pulsatile mode, different onsets of a synchronous time-varying pump speed pattern were tested. Our data indicate that the effectiveness of unloading in continuous mode depends on the contractility of the native ventricle. Hypocontractile ventricles are most easily unloaded, while ventricles with moderate contractility require high continuous pump speeds to achieve notable unloading. In pulsatile mode, the pump timing is an important determinant of pump/cardiovascular system interaction, with a counterpulsation setting yielding the best unloading.

Biomechanical Phenomena↗

Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom.

UNLABELLED: We have developed a biventricular dynamic physical cardiac phantom to test gated blood-pool (GBP) SPECT image-processing algorithms. Such phantoms provide absolute values against which to assess accuracy of both right and left computed ventricular volume and ejection fraction (EF) measurements. METHODS: Two silicon-rubber chambers driven by 2 piston pumps simulated crescent-shaped right ventricles wrapped partway around ellopsoid left ventricles. Twenty experiments were performed at Ghent University, for which right and left ventricular true volume and EF ranges were 65-275 mL and 55-165 mL and 7%-49% and 12%-69%, respectively. Resulting 64 x 64 simulated GBP SPECT images acquired at 16 frames per R-R interval were sent to Columbia University, where 2 observers analyzed images independently of each other, without knowledge of true values. Algorithms automatically segmented right ventricular activity volumetrically from left ventricular activity. Automated valve planes, midventricular planes, and segmentation regions were presented to observers, who accepted these choices or modified them as necessary. One observer repeated measurements >1 mo later without reference to previous determinations. RESULTS: Linear correlation coefficients (r) of the mean of the 3 GBP SPECT observations versus true values for right and left ventricles were 0.80 and 0.94 for EF and 0.94 and 0.95 for volumes, respectively. Correlations for right and left ventricles were 0.97 and 0.97 for EF and 0.96 and 0.89 for volumes, respectively, for interobserver agreement and 0.97 and 0.98 for EF and 0.96 and 0.90 for volumes, respectively, for intraobserver agreement. No trends were detected, though volumes and right ventricular EFs were significantly higher than true values. CONCLUSION: Overall, GBP SPECT measurements correlated strongly with true values. The phantom evaluated shows considerable promise for helping to guide algorithm developments for improved GBP SPECT accuracy.

Computer Simulation↗

Design of a new pulsatile bioreactor for tissue engineered aortic heart valve formation.

Evidence has been gathered that biomechanical factors have a significant impact on cell differentiation and behavior in in vitro cell cultures. The aim of this bioreactor is to create a physiological environment in which tissue engineered (TE) aortic valves seeded with human cells can be cultivated during a period of several days. The bioreactor consists of 2 major parts: the left ventricle (LV) and the afterload consisting of a compliance, representing the elastic function of the large arteries, and in series a resistance, mimicking the arterioles and capillaries. The TE aortic valve is placed between the LV and the compliance. With controllable resistance, compliance, stroke volume and frequency, and hydrodynamic conditions can be changed over a wide physiological range. This study resulted in a prototype of a compact pulsatile flow system for the creation of TE aortic valves. In addition a biocompatibility study of the used materials is performed.

Aortic Valve↗

Mock loop testing of On-x prosthetic mitral valve with Doppler echocardiography.

Previous in vitro testing (mainly in aortic position) and clinical experience (often based on Doppler echocardiographic observations) demonstrated an excellent hemodynamic behavior of the On-X valve. However, integrative studies including simultaneous hemodynamic pressure and flow measurements and Doppler echocardiography are lacking. Using our computer-controlled mock loop system, two samples of the Mitral 27/29 and one sample of the Conform-X Mitral 25/33 are tested in mitral position. Data include transvalvular pressure gradient and flow as well as transthoracic Doppler echocardiography. The valves are tested under three pressure conditions (ventricular systolic pressure of 100, 130, and 160 mm Hg) at three different heart rates (60, 100, and 140 beats/min). In addition, ventricular pressure conditions simulating fibrillation are imposed. Both valve types show similar hydrodynamic characteristics and have an effective orifice area of 2.1 cm2 and a performance index of 0.56 for a cardiac output of 3.5 L/min. Regurgitant volumes remain below 6 ml.

Coronary Circulation↗

Effect of rotary blood pump failure on left ventricular energetics assessed by mathematical modeling.

In this study, we used a mathematical model to study the influence of backflow through a failing rotary blood pump. We performed simulations based on animal experiments that were published earlier by Nishida et al., who used the Medos Microdiagonal pump to assess the acute effect of sudden pump failure. The mathematical model consists of validated cardiac and arterial modules and a pump module. We could evaluate the influence of pump failure with mechanoenergetic parameters and wall stress obtained from model output. Simulations were performed at baseline and after 15 min of backflow in a control group and a heart failure group. Simulation results agreed well with the experiment. Stroke volume, aortic flow, and stress time integral increased significantly because of pump failure. However, total systemic flow and arterial pressure were not altered by backflow, and a life-threatening situation did not appear.

Animals↗

Model dependence of gated blood pool SPECT ventricular function measurements.

BACKGROUND: Calculation differences between various gated blood pool (GBP) single photon emission computed tomography (SPECT) (GBPS) algorithms may arise as a result of different modeling assumptions. Little information has been available thus far regarding differences for right ventricular (RV) function calculations, for which GBPS may be uniquely well suited. METHODS AND RESULTS: Measurements of QBS (Cedars-Sinai Medical Center, Los Angeles, Calif) and BP-SPECT (Columbia University, New York, NY) algorithms were evaluated. QBS and BP-SPECT left ventricular (LV) ejection fraction (EF) correlated strongly with conventional planar-GBP LVEF for 422 patients (r = 0.81 vs r = 0.83). QBS correlated significantly more strongly with BP-SPECT for LVEF than for RVEF (r = 0.80 vs r = 0.41). Both algorithms demonstrated significant gender differences for 31 normal subjects. BP-SPECT normal LVEF (67% +/- 9%) was significantly closer to values in the magnetic resonance imaging (MRI) literature (68% +/- 5%) than QBS (58% +/- 9%), but both algorithms underestimated normal RVEF (52% +/- 7% and 50% +/- 9%) compared with the MRI literature (64% +/- 9%). For 21 patients, QBS correlated similarly to MRI as BP-SPECT for LVEF (r = 0.80 vs r = 0.85) but RVEF correlation was significantly weaker (r = 0.47 vs r = 0.81). For 16 dynamic phantom simulations, QBS LVEF correlated similarly to BP-SPECT (r = 0.81 vs r = 0.91) but QBS RVEF correlation was significantly weaker (r = 0.62 vs r = 0.82). Volumes were lower by QBS than BP-SPECT for all data types. CONCLUSIONS: Both algorithms produced LV parameters that correlated strongly with all forms of image data, but all QBS RV relationships were significantly different from BP-SPECT RV relationships. Differences between the two algorithms were attributed to differences in their underlying ventricular modeling assumptions.

Algorithms↗

Hemodynamic modes of ventricular assist with a rotary blood pump: continuous, pulsatile, and failure.

Pulsatile operation of rotary blood pumps (RBPs) has received interest due to potential concern with nonphysiological hemodynamics. This study aimed to gain insight to the effects of various RBP modes on the heart-device interaction. A Deltastream diagonal pump (Medos Medizintechnik GmbH) was inserted in a cardiovascular simulator with apical-to-ascending aorta cannulation. The pump was run in continuous mode with incrementally increasing rotating speed (0-5000 rpm). This was repeated for three heart rates (50-100-150 bpm) and three levels of left ventricular (LV) contractility. Subsequently, the Deltastream was run in pulsatile mode to elucidate the effect of (de)synchronization between heart and pump. LV volume and pressure, arterial pressure, flows, and energetic parameters were used to evaluate the interaction. Pump failure (0 rpm) resulted in aortic pressure drops (17-46 mm Hg) from baseline. In continuous mode, pump flow compensated by diminished aortic flow, thus yielding constant total flow. High continuous rotating speed resulted in acute hypertension (mean aortic pressure up to 178 mm Hg). In pulsatile mode, unmatched heart and pulsatile pump rates yielded unphysiologic pressure and flow patterns and LV unloading was found to be highly dependent on synchronization phase. Optimal unloading was achieved when the minimum rotating speed occurred at end-systole. We conclude that, in continuous mode, a perfusion benefit can only be achieved if the continuous pump flow exceeds the preimplant (baseline) cardiac output. Pulsatile mode of support results in complex pressure and volume variations and requires accurate triggering to achieve optimal unloading.

Data Interpretation, Statistical↗

Modeling ventricular function during cardiac assist: does time-varying elastance work?

The time-varying elastance theory of Suga et al. is widely used to simulate left ventricular function in mathematical models and in contemporary in vitro models. We investigated the validity of this theory in the presence of a left ventricular assist device. Left ventricular pressure and volume data are presented that demonstrate the heart-device interaction for a positive-displacement pump (Novacor) and a rotary blood pump (Medos). The Novacor was implanted in a calf and used in fixed-rate mode (85 BPM), whereas the Medos was used at several flow levels (0-3 l/min) in seven healthy sheep. The Novacor data display high beat-to-beat variations in the amplitude of the elastance curve, and the normalized curves deviate strongly from the typical bovine curve. The Medos data show how the maximum elastance depends on the pump flow level. We conclude that the original time-varying elastance theory insufficiently models the complex hemodynamic behavior of a left ventricle that is mechanically assisted, and that there is need for an updated ventricular model to simulate the heart-device interaction.

Animals↗