Metal-enhanced phosphorescence: interpretation in terms of triplet-coupled radiating plasmons.

We report our detailed metal-enhanced phosphorescence (MEP) findings using Rose Bengal at low temperature. Silver Island Films (SiFs) in close proximity to Rose Bengal significantly enhance the phosphorescence emission intensity. In this regard, a 5-fold brighter phosphorescence intensity of Rose Bengal was observed from SiFs as compared to a glass control sample at 77 K. In addition, several factors affecting MEP, such as distance dependence and silver film morphology, were also investigated. Our findings suggest that both singlet and triplet states can couple to surface plasmons and enhance both fluorescence and phosphorescence yields. This finding suggests that MEP can be used to promote triplet-based assays, such as those used in photodynamic therapy.

Fluorescent Dyes↗

Metal-enhanced fluorescence from gold surfaces: angular dependent emission.

The first observation of Metal-Enhanced Fluorescence (MEF) from large gold colloids is presented. Gold colloids, 40 and 200 nm diameter, were deposited onto glass substrates in a homogeneous fashion. The angular-dependent fluorescence emission of FITC-HSA, adsorbed onto gold colloids, was measured on a rotating stage which was used to evaluate MEF at all spatial angles. The emission intensity of FITC-HSA was found to be up to 2.5-fold brighter than the emission on bare glass substrates at an angle of 270 degrees. This is explained by the Radiating Plasmon Model, whereby the combined system, composed of the fluorophore and the metal colloids, emits with the photophysical characteristics of the fluorophore, after the excitation and the partial radiationless energy transfer between the excited states of the fluorophore and the surface plasmons of the gold colloids. The fluorescence enhancement was found to be higher with 200 nm gold colloids as compared to 40 nm colloids due to the increased contribution of the scattering portion of the 200 nm gold colloid extinction spectrum. These observations suggest that gold colloids could be used in MEF applications, offering more stable surfaces than the commonly used silvered surfaces, for applications requiring longer term storage and use.

Colloids↗

Microwave triggered metal enhanced chemiluminescence: Quantitative protein determination.

We present a new technology that offers a faster alternative to the chemiluminescence-based detection that is used in protein assay platforms today. By combining the use of silver nanostructures with chemiluminescent species, a technique that our laboratories have recently shown can enhance the system photon flux over 50-fold, with the use of low-power microwave heating to additionally accelerate, in essence "trigger", chemiluminescence-based reactions, then both ultrafast and ultrabright chemiluminescence assays can be realized. In addition, the preferential heating of the nanostructures by microwaves affords for microwave triggered metal enhanced chemiluminescence (MT-MEC) to be localized in proximity to the silvered surfaces, alleviating unwanted emission from the distal solution. To demonstrate MT-MEC, we have constructed a model assay sensing platform on both silvered and glass surfaces, where comparison with the identical glass substrate-based assay serves to confirm the significant benefits of using silver nanostructures for metal-enhanced chemiluminescence. Our new model assay technology can detect femtomoles of biotinylated BSA in less than 2 min and can indeed be modified to both detect and quantify a great many other biomolecules as well. As compared to traditional western blot approaches, MT-MEC offers protein quantification, high-sensitivity detection combined with ultrafast assay times, i.e., <2 min.

Animals↗

Multicolor directional surface plasmon-coupled chemiluminescence.

In reports over the past several years, we have demonstrated the efficient collection of optically excited fluorophore emission by its coupling to surface plasmons on thin metallic films, where the coupled luminescence was highly directional and polarized. This phenomenon is referred to as surface plasmon-coupled emission (SPCE). In this current study, we have extended this technique to include chemiluminescing species and subsequentially now report the observation of surface plasmon-coupled chemiluminescence (SPCC), where the luminescence from chemically induced electronic excited states couples to surface plasmons in thin continuous metal films. The SPCC is highly directional and predominantly p-polarized, strongly suggesting that the emission is from surface plasmons instead of the luminophores themselves. This indicates that surface plasmons can be directly excited from chemically induced electronic excited states and excludes the possibility that the plasmons are created by incident excitation light. This phenomenon has been observed for a variety of chemiluminescent species in the visible spectrum, ranging from blue to red, and also on a variety of metals, namely, aluminum, silver, and gold. Our findings suggest new chemiluminescence sensing strategies on the basis of localized, directional, and polarized chemiluminescence detection, especially given the wealth of assays that currently employ chemiluminescence-based detection.

Aluminum↗

Multicolor microwave-triggered metal-enhanced chemiluminescence.

We describe a novel platform technology for both significantly enhancing and obtaining chemiluminescence signatures "on-demand", subsequently named Microwave-Triggered Metal-Enhanced Chemiluminescence. By combining the use of silver nanoparticles to plasmon enhance chemiluminescence with the use of low power microwaves to localize heating around the nanostructures, we can both optically amplify and trigger chemiluminescence reactions. This approach is a significant advantage over traditional chemiluminescence techniques and methodologies, such as those used for Western Blots, which typically require long periods of time to collect chemiluminescence and offer few possibilities of optically amplifying the signatures.

Algorithms↗

Fast and sensitive DNA hybridization assays using microwave-accelerated metal-enhanced fluorescence.

A new, fast, and sensitive DNA hybridization assay platform based on microwave-accelerated metal-enhanced fluorescence (MAMEF) is presented. Thiolated oligonucleotide anchors were immobilized onto silver nanoparticles on a glass substrate. The hybridization of the complementary fluorescein-labeled DNA target with the surface-bound oligonucleotides was completed within 20 s upon heating with low-power microwaves. In addition, the signal is optically amplified, a consequence of close proximity of the fluorophore to the silvered substrate. In this proof-of-principle methodology, as low as 50 nM of a target DNA was detected, although we envisage far-lower detection limits. Control experiments, where the surface-bound oligonucleotide was omitted, were also performed to determine the extent of non-specific binding. In these studies a significantly reduced non-specific adsorption was found when using microwave heating near to silvered structures as compared to room temperature incubation. These findings suggest that MAMEF could be a most useful alternative to the DNA hybridization assays used today, especially with regard to substantially increasing both the assay rapidity and sensitivity.

Aminoacridines↗

Metal-enhanced chemiluminescence.

In this short paper we report the interactions of silver island films with chemiluminescing species. Our findings show that silver island films can increase the detectability of chemiluminescent reactions/species, with an approximately 5-fold increase in signal intensity. This finding not only suggests the use of silver nanostructures to amplify chemiluminscent signatures in assay platforms, and therefore increase the detectability of analytes or biospecies, but more importantly, suggests that surface plasmons can be directly excited by chemically induced electronically excited molecules. This finding is of significance towards our understanding of fluorophore-metal interactions, a relatively new near-field fluorescence concept, recently named metal-enhanced fluorescence and also radiative decay engineering.

Energy Transfer↗