PubMed Health⌕ Search

Biomedical subjects

Stylianos Drisis

Publications and source records attributed to Stylianos Drisis.

3 recordsLinked to original sources

Computer-aided detection of colonic polyps using low-dose CT acquisitions.

RATIONALE AND OBJECTIVES: This report proposes an alternative method for the automatic detection of colonic polyps that is robust enough to be directly applicable on low-dose computed tomographic data. MATERIALS AND METHODS: The polyp modeling process takes into account both the gray-level appearance of polyps (intensity profiles) and their geometry (extended Gaussian images). Spherical harmonic decompositions are used for comparison purposes, allowing fast estimation of the similarity between a candidate and a set of previously computed models. Starting from the original raw data (acquired at 55 mA), five patient data sets (prone and supine scans) are reconstructed at different dose levels (to 5 mA) by using different kernel filters, slice overlaps, and increments. Additionally, the efficacy of applying an edge-preserving smoothing filter before detection is assessed. RESULTS: Although image quality decreases when decreasing acquisition milliamperes, all polyps greater than 6 mm are detected successfully, even at 15 mA. Although not important at high doses, smoothing improves detection results for ultra-low-dose (tube current<15 mA) data. CONCLUSION: The advantage of low-dose scans is a significant decrease in effective dose from 4.93 to 1.61 mSv while retaining high detection values, particularly important when thinking of population screening.

Algorithms↗

Computer aided detection for low-dose CT colonography.

The paper describes a method for automatic detection of colonic polyps, robust enough to be directly applied to low-dose CT colonographic datasets. Polyps are modeled using gray level intensity profiles and extended Gaussian images. Spherical harmonic decompositions ensure an easy comparison between a polyp candidate and a set of polypoid models, found in a previously built database. The detection sensitivity and specificity values are evaluated at different dose levels. Starting from the original raw-data (acquired at 55mAs), 5 patient datasets (prone and supine scans) are reconstructed at different dose levels (down to 5mAs), using different kernel filters and slice increments. Although the image quality decreases when lowering the acquisition mAs, all polyps above 6mm are successfully detected even at 15 mAs. Accordingly the effective dose can be reduced from 4.93mSv to 1.61 mSv, without affecting detection capabilities, particularly important when thinking of population screening.

Algorithms↗

Plaque and stent artifact reduction in subtraction CT angiography using nonrigid registration and a volume penalty.

Computed tomography angiography (CTA) is an established tool for vessel imaging. Yet, high-intense structures in the contrast image can seriously hamper luminal visualisation. This can be solved by subtraction CTA, where a native image is subtracted from the contrast image. However, patient and organ motion limit the application of this technique. Within this paper, a fully automated intensity-based nonrigid 3D registration algorithm for subtraction CT angiography is presented, using a penalty term to avoid volume change during registration. Visual and automated validation on four clinical datasets clearly show that the algorithm strongly reduces motion artifacts in subtraction CTA. With our method, 39% to 99% of the artifacts disappear, also those caused by minimal displacement of stents or calcified plaques. This results in a better visualisation of the vessel lumen, also of the smaller vessels, allowing a faster and more accurate inspection of the whole vascular structure, especially in case of stenosis.

Algorithms↗