Selective solid-phase extraction of cholesterol using molecularly imprinted polymers and its application in different biological samples.

Non-covalent molecularly imprinted polymers (MIPs) of cholesterol were prepared by UV initiated polymerization. A polymer that had the highest binding selectivity and capability was used as solid-phase extraction (SPE) sorbents for direct extraction of cholesterol from different biological samples (human serum, cow milk, yolk, shrimp, pork and beef). The extraction conditions of molecularly imprinted SPE (MISPE) were optimized and the optimum protocol was: conditioning MISPE cartridges with n-hexane, loading with n-hexane, washing with n-hexane and n-hexane:toluene=9:1, respectively, then eluting with chloroform:ethanol:acetic acid=3:1:1. Cholesterol MISPE selectively recognized, effectively trapped and pre-concentrated cholesterol over a concentration range of 10-80 microg/mL. Recoveries ranged from 80.6% to 92.7%, with R.S.D. lower than 9.8%. Under the optimal condition, MISPE recoveries of spiked human serum, yolk, cow milk, shrimp, pork and beef were 91.1%, 80.4%, 86.6%, 78.2%, 81.4% and 80.1%, respectively. Compared with C18 SPE, almost all of the matrix interferences were removed after MISPE, and better baselines and higher selectivity were achieved.

Animals↗

Capillary electrophoresis with end-column amperometric detection of urinary 8-hydroxy-2'-deoxyguanosine.

Urinary 8-hydroxy-2'-deoxyguanosine (8OHdG) is an excellent marker of oxidative DNA damage. Until now, urinary 8OHdG has been measured by high-performance liquid chromatography with electrochemical detection. A simple and sensitive method for the analysis of urinary 8OHdG by capillary electrophoresis with end-column amperometric detection has been developed in our laboratory. A single-step solid-phase extraction procedure was optimized and used for extracting 8OHdG from human urine. To improve the sensitivity of this method, a new focusing technique based on a dynamic pH junction was used. The limit of detection was 20 nM (signal-to-noise ratio S/N = 3), the linear range was 50 nM-10 microM, and the correlation coefficient was better than 0.999. The relative standard deviation (RSD) was found to be 0.57% for migration time, and 4.79% for peak current. To show the usefulness of the method, the urinary concentration of 8OHdG in nine healthy persons and ten cancer patients was determined. The urinary concentration of 8OHdG in cancer patients was significantly higher than that in healthy persons.

Biomarkers↗