A greedy heuristic using adjoint functions for the optimization of seed and needle configurations in prostate seed implant.

We continue our work on the development of an efficient treatment-planning algorithm for prostate seed implants by incorporation of an automated seed and needle configuration routine. The treatment-planning algorithm is based on region of interest (ROI) adjoint functions and a greedy heuristic. As defined in this work, the adjoint function of an ROI is the sensitivity of the average dose in the ROI to a unit-strength brachytherapy source at any seed position. The greedy heuristic uses a ratio of target and critical structure adjoint functions to rank seed positions according to their ability to irradiate the target ROI while sparing critical structure ROIs. Because seed positions are ranked in advance and because the greedy heuristic does not modify previously selected seed positions, the greedy heuristic constructs a complete seed configuration quickly. Isodose surface constraints determine the search space and the needle constraint limits the number of needles. This study additionally includes a methodology that scans possible combinations of these constraint values automatically. This automated selection scheme saves the user the effort of manually searching constraint values. With this method, clinically acceptable treatment plans are obtained in less than 2 min. For comparison, the branch-and-bound method used to solve a mixed integer-programming model took close to 2.5 h to arrive at a feasible solution. Both methods achieved good treatment plans, but the speedup provided by the greedy heuristic was a factor of approximately 100. This attribute makes this algorithm suitable for intra-operative real-time treatment planning.

Algorithms↗

Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning.

PURPOSE: Cone-beam computed tomography (CBCT) images are currently used for positioning verification. However, it is yet unknown whether CBCT could be used in dose calculation for replanning in adaptive radiation therapy. This study investigates the dosimetric feasibility of CBCT-based treatment planning. METHODS AND MATERIALS: Hounsfield unit (HU) values and profiles of Catphan, homogeneous/inhomogeneous phantoms, and various tissue regions of patients in CBCT images were compared to those in CT. The dosimetric consequence of the HU variation was investigated by comparing CBCT-based treatment plans to conventional CT-based plans for both phantoms and patients. RESULTS: The maximum HU difference between CBCT and CT of Catphan was 34 HU in the Teflon. The differences in other materials were less than 10 HU. The profiles for the homogeneous phantoms in CBCT displayed reduced HU values up to 150 HU in the peripheral regions compared to those in CT. The scatter and artifacts in CBCT became severe surrounding inhomogeneous tissues with reduced HU values up to 200 HU. The MU/cGy differences were less than 1% for most phantom cases. The isodose distributions between CBCT-based and CT-based plans agreed very well. However, the discrepancy was larger when CBCT was scanned without a bowtie filter than with bowtie filter. Also, up to 3% dosimetric error was observed in the plans for the inhomogeneous phantom. In the patient studies, the discrepancies of isodose lines between CT-based and CBCT-based plans, both 3D and IMRT, were less than 2 mm. Again, larger discrepancy occurred for the lung cancer patients. CONCLUSION: This study demonstrated the feasibility of CBCT-based treatment planning. CBCT-based treatment plans were dosimetrically comparable to CT-based treatment plans. Dosimetric data in the inhomogeneous tissue regions should be carefully validated.

Brain Neoplasms↗

Digital tomosynthesis with an on-board kilovoltage imaging device.

PURPOSE: To generate on-board digital tomosynthesis (DTS) and reference DTS images for three-dimensional image-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT). METHODS AND MATERIALS: Three clinical cases (prostate, head-and-neck, and liver) were selected to illustrate the capabilities of on-board DTS for IGRT. Corresponding reference DTS images were reconstructed from digitally reconstructed radiographs computed from planning CT image sets. The effect of scan angle on DTS slice thickness was examined by computing the mutual information between coincident CBCT and DTS images, as the DTS scan angle was varied from 0 degrees to 165 degrees . A breath-hold DTS acquisition strategy was implemented to remove respiratory motion artifacts. RESULTS: Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information than either kilovoltage or megavoltage radiographs. Breath-hold DTS acquisition improved soft-tissue visibility by suppressing respiratory motion. CONCLUSIONS: Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Breath-hold DTS is a potential alternative to on-board CBCT for sites prone to respiratory motion.

Algorithms↗

A quality assurance program for the on-board imagers.

To develop a quality assurance (QA) program for the On-Board Imager (OBI) system and to summarize the results of these QA tests over extended periods from multiple institutions. Both the radiographic and cone-beam computed tomography (CBCT) mode of operation have been evaluated. The QA programs from four institutions have been combined to generate a series of tests for evaluating the performance of the On-Board Imager. The combined QA program consists of three parts: (1) safety and functionality, (2) geometry, and (3) image quality. Safety and functionality tests evaluate the functionality of safety features and the clinical operation of the entire system during the tube warm-up. Geometry QA verifies the geometric accuracy and stability of the OBI/CBCT hardware/software. Image quality QA monitors spatial resolution and contrast sensitivity of the radiographic images. Image quality QA for CBCT includes tests for Hounsfield Unit (HU) linearity, HU uniformity, spatial linearity, and scan slice geometry, in addition. All safety and functionality tests passed on a daily basis. The average accuracy of the OBI isocenter was better than 1.5 mm with a range of variation of less than 1 mm over 8 months. The average accuracy of arm positions in the mechanical geometry QA was better than 1 mm, with a range of variation of less than 1 mm over 8 months. Measurements of other geometry QA tests showed stable results within tolerance throughout the test periods. Radiographic contrast sensitivity ranged between 2.2% and 3.2% and spatial resolution ranged between 1.25 and 1.6 lp/mm. Over four months the CBCT images showed stable spatial linearity, scan slice geometry, contrast resolution (1%; <7 mm disk) and spatial resolution (>6 lp/cm). The HU linearity was within +/-40 HU for all measurements. By combining test methods from multiple institutions, we have developed a comprehensive, yet practical, set of QA tests for the OBI system. Use of the tests over extended periods show that the OBI system has reliable mechanical accuracy and stable image quality. Nevertheless, the tests have been useful in detecting performance deficits in the OBI system that needed recalibration. It is important that all tests are performed on a regular basis.

Equipment Failure Analysis↗

Treatment planning for prostate brachytherapy using region of interest adjoint functions and a greedy heuristic.

We have developed an efficient treatment-planning algorithm for prostate implants that is based on region of interest (ROI) adjoint functions and a greedy heuristic. For this work, we define the adjoint function for an ROI as the sensitivity of the average dose in the ROI to a unit-strength brachytherapy source at any seed position. The greedy heuristic uses a ratio of target and critical structure adjoint functions to rank seed positions according to their ability to irradiate the target ROI while sparing critical structure ROIs. This ratio is computed once for each seed position prior to the optimization process. Optimization is performed by a greedy heuristic that selects seed positions according to their ratio values. With this method, clinically acceptable treatment plans are obtained in less than 2 s. For comparison, a branch-and-bound method to solve a mixed integer-programming model took more than 50 min to arrive at a feasible solution. Both methods achieved good treatment plans, but the speedup provided by the greedy heuristic was a factor of approximately 1500. This attribute makes this algorithm suitable for intra-operative real-time treatment planning.

Algorithms↗

Clinical implementation of AAPM TG61 protocol for kilovoltage x-ray beam dosimetry.

Historically, there have been a variety of dosimetry protocols used for kilovoltage x-ray therapy beams with a set of conversion factors and correction factors taken from different references. Corresponding to the continued installation and use of kilovoltage machines, the American Association of Physicists in Medicine (AAPM) presented a unified protocol developed by Task Group 61 (TG61). TG61 determines the absorbed dose to water with an ionization chamber calibrated in air in terms of air kerma (Nk). TG61 presents both an in-air method and an in-phantom method. In this work we only examine the TG61 in-air method. Our traditional dosimetry procedure, which is based upon NCRP Report 69 and on material found in standard medical physics texts, has been compared to the TG61. A variety of kilovoltage beam energies were examined with a set of various field sizes and source to surface distances. TG61 published updated data for the mass absorption coefficient ratios, backscatter factors, and the average energy per ion pair factor. The following conclusions have been reached: (1) Our traditional procedures and the TG61 protocol for in-air measurements are equivalent. (2) The conversion and correction factors used in TG61 are different by up to 4.5% compared to the old factors that we have used. (3) The application of the TG61 factors can result in up to 5% differences in the determination of the absorbed dose.

Air↗