Computer-aided detection of amorphous calcifications.

OBJECTIVE: Computer-aided detection (CAD) systems have been used successfully to detect malignant calcifications on mammography, with sensitivities ranging from 86% to 99%. Amorphous calcifications are a subset of small indistinct calcifications of intermediate concern that have a 20% likelihood of being malignant and that are frequently overlooked on mammography. The purpose of our study was to determine the sensitivity of one commercially available CAD system for detecting amorphous calcifications. MATERIALS AND METHODS: A commercially available CAD system evaluated mammograms of 82 patients with 85 mammographically detected and histologically sampled groups of amorphous calcifications (21 malignant, 14 high risk, and 50 benign). The sensitivity of the system for detecting the calcifications on at least one image of the two-view mammographic examination (case sensitivity) and on each individual mammographic image (image sensitivity) was determined. Findings were correlated with results from large core needle biopsy or surgical excision in each case. RESULTS: The CAD system detected amorphous calcifications in 43 of 85 cases (case sensitivity, 51%) and in 59 of 146 mammographic images (image sensitivity, 40%). The case sensitivities by histologic outcome were 57% for malignant calcifications, 29% for high-risk calcifications, and 54% for benign calcifications. An average of 2.0 false-positive marks were displayed per case. CONCLUSION: The CAD sensitivity for malignant amorphous calcifications is markedly lower than previously reported for all malignant calcifications. Breast imaging radiologists who use CAD systems should continue to search diligently for these difficult-to-detect lesions.

Adult↗

Stereotactic breast biopsy of noncalcified lesions: a cost-minimization analysis comparing 14-gauge multipass automated core biopsy to 14- and 11-gauge vacuum-assisted biopsy.

A decision model was used to compare the relative costs of the 14-gauge automated gun technique to the 14-gauge and 11-gauge vacuum-assisted techniques for stereotactic biopsy of noncalcified breast lesions. Probability and cost variables were estimated from clinical experience with 76 automated gun biopsies, seventy-eight 14-gauge vacuum-assisted biopsies and thirty-nine 11-gauge vacuum-assisted biopsies. The 14-gauge automated gun was the preferred strategy from a cost standpoint: the 14-gauge vacuum technique was 1.19 times more expensive, and the 11-gauge was 1.22 times more expensive.

Biopsy↗