PubMed Health⌕ Search

Biomedical subjects

Sumin Zhou

Publications and source records attributed to Sumin Zhou.

8 recordsLinked to original sources

Prospective assessment of dosimetric/physiologic-based models for predicting radiation pneumonitis.

PURPOSE: Clinical and 3D dosimetric parameters are associated with symptomatic radiation pneumonitis rates in retrospective studies. Such parameters include: mean lung dose (MLD), radiation (RT) dose to perfused lung (via SPECT), and pre-RT lung function. Based on prior publications, we defined pre-RT criteria hypothesized to be predictive for later development of pneumonitis. We herein prospectively test the predictive abilities of these dosimetric/functional parameters on 2 cohorts of patients from Duke and The Netherlands Cancer Institute (NKI). METHODS AND MATERIALS: For the Duke cohort, 55 eligible patients treated between 1999 and 2005 on a prospective IRB-approved study to monitor RT-induced lung injury were analyzed. A similar group of patients treated at the NKI between 1996 and 2002 were identified. Patients believed to be at high and low risk for pneumonitis were defined based on: (1) MLD; (2) OpRP (sum of predicted perfusion reduction based on regional dose-response curve); and (3) pre-RT DLCO. All doses reflected tissue density heterogeneity. The rates of grade > or =2 pneumonitis in the "presumed" high and low risk groups were compared using Fisher's exact test. RESULTS: In the Duke group, pneumonitis rates in patients prospectively deemed to be at "high" vs. "low" risk are 7 of 20 and 9 of 35, respectively; p = 0.33 one-tailed Fisher's. Similarly, comparable rates for the NKI group are 4 of 21 and 6 of 44, respectively, p = 0.41 one-tailed Fisher's. CONCLUSION: The prospective model appears unable to accurately segregate patients into high vs. low risk groups. However, considered retrospectively, these data are consistent with prior studies suggesting that dosimetric (e.g., MLD) and functional (e.g., PFTs or SPECT) parameters are predictive for RT-induced pneumonitis. Additional work is needed to better identify, and prospectively assess, predictors of RT-induced lung injury.

Adult↗

A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung.

PURPOSE: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to divert dose away from higher-functioning lung, potentially reducing lung toxicity. We present a methodology for achieving this aim and test it in intensity-modulated radiotherapy (IMRT) treatment-planning. METHODS AND MATERIALS: IMRT treatment plans were generated with and without SPECT guidance and compared for 5 patients. Healthy lung was segmented into four regions on the basis of SPECT intensity in the SPECT plan. Dose was sequentially allowed to the target via regions of increasing SPECT intensity. This process results in reduction of dose to functional lung, reflected in the dose-function histogram (DFH). The plans were compared using DFHs and F(20)/F(30) values (F(x) is the functional lung receiving dose above x Gy). RESULTS: In all cases, the SPECT-guided plan produced a more favorable DFH compared with the non-SPECT-guided plan. Additionally, the F(20) and F(30) values were reduced for all patients by an average of 13.6% +/- 5.2% and 10.5% +/- 5.8%, respectively. In all patients, DFHs of the two highest-functioning SPECT regions were reduced, whereas DFHs of the two lower-functioning regions were increased, illustrating the dose "give-take" between SPECT regions during redistribution. CONCLUSIONS: SPECT-guided IMRT shows potential for reducing the dose delivered to highly functional lung regions. This dose reduction could reduce the number of high-grade pneumonitis cases that develop after radiation treatment and improve patient quality of life.

Algorithms↗

Assessing the ability of the antiangiogenic and anticytokine agent thalidomide to modulate radiation-induced lung injury.

PURPOSE: Thalidomide has broad anticytokine properties, which might protect normal tissues in patients undergoing chemoradiotherapy. The purpose of this study was to determine the maximal tolerated dose of thalidomide when used in combination with vinorelbine plus thoracic radiotherapy. METHODS AND MATERIALS: Eligible patients had inoperable Stage III non-small-cell lung cancer, a Karnofsky Performance Status>or=70, and life expectancy>or=6 months. Patients underwent pretreatment evaluation of lung function. Radiotherapy consisted of 66 Gy in 6.5 weeks. Vinorelbine was administered i.v. (5 mg/m2) 3 times per week just before radiotherapy. Thalidomide was begun at 50 mg, p.o., on day 1 of chemoradiotherapy and continued once daily for 6 months. Side effects were scored using National Cancer Institute Common Toxicity Criteria. RESULTS: Ten patients were enrolled. Of the first 6 patients, 2 developed major thrombotic events that were believed to be possibly related to thalidomide. The study was suspended and modified to require prophylactic anticoagulation. Of the last 4 patients, 2 developed dose-limiting toxicity attributable to thalidomide; both patients required a dose reduction of thalidomide to <50 mg/day. Because the drug is not available in an oral product providing <50 mg/day, the study was closed. CONCLUSIONS: The combination of thalidomide concurrently with thoracic radiotherapy and vinorelbine resulted in excessive toxicity.

Aged↗

"Anatomically-correct" dosimetric parameters may be better predictors for esophageal toxicity than are traditional CT-based metrics.

PURPOSE: Incidental esophageal irradiation during lung cancer therapy often causes morbidity. There is interest in trying to relate esophageal dosimetric parameters to the risk of injury. These parameters typically rely on CT-defined esophageal contours, and thus systematic limitations in esophageal contouring will influence these parameters. We herein assess the ability of a correction method, based on physiologic principles, to improve the predictive power of dosimetric parameters for radiation-induced esophageal injury. METHODS AND MATERIALS: Esophageal contours for 236 patients treated for lung cancer were quantitatively analyzed. All patients received three-dimensional planning, and all contours were generated by the same physician on axial CT images. Traditional dose-volume histogram (DVH)-based dosimetric parameters were extracted from the three-dimensional data set. A second set of "anatomically correct" dosimetric parameters was derived by adjusting the contours to reflect the known shape of the esophagus. Each patient was scored for acute and late toxicity using ROTG criteria. Univariate analysis was used to assess the predictive power of corrected and uncorrected dosimetric parameters (e.g., mean dose, V(50), and V(60)) for toxicity. The p values were taken as a measure of their significance. RESULTS: The univariate results indicate that both corrected and uncorrected dosimetric parameters are generally predictors for toxicity. The corrected parameters are more highly correlated (lower p value) with outcomes than the uncorrected metrics. CONCLUSIONS: The inclusion of corrections, based on anatomic realities, to DVH-based dosimetric parameters may provide dosimetric parameters that are better correlated with clinical outcomes than are traditional DVH-based metrics.

Analysis of Variance↗

Dosimetric and clinical predictors for radiation-induced esophageal injury.

PURPOSE: To evaluate the clinical and three-dimensional dosimetric parameters associated with esophageal injury after radiotherapy (RT) for non-small-cell lung cancer. METHODS AND MATERIALS: The records of 254 patients treated for non-small-cell lung cancer between 1992 and 2001 were reviewed. A variety of metrics describing the esophageal dose were extracted. The Radiation Therapy Oncology Group toxicity criteria for grading of esophageal injury were used. The median follow-up time for all patients was 43 months (range, 0.5-120 months). Logistic regression analysis, contingency table analyses, and Fisher's exact tests were used for statistical analysis. RESULTS: Acute toxicity occurred in 199 (78%) of 254 patients. For acute toxicity of Grade 2 or worse, twice-daily RT, age, nodal stage of N2 or worse, and most dosimetric parameters were predictive. Late toxicity occurred in 17 (7%) of 238 patients. The median and maximal time to the onset of late toxicity was 5 and 40 months after RT, respectively. Late toxicity occurred in 2%, 3%, 17%, 26%, and 100% of patients with acute Grade 0, 1, 2, 3, and 4 toxicity, respectively. For late toxicity, the severity of acute toxicity was most predictive. CONCLUSION: A variety of dosimetric parameters are predictive of acute and late esophageal injury. A strong correlation between the dosimetric parameters prevented a comparison between the predictive abilities of these metrics. The presence of acute injury was the most predictive factor for the development of late injury. Additional studies to define better the predictors of RT-induced esophageal injury are needed.

Adult↗

Predicting radiotherapy-induced cardiac perfusion defects.

The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated with tangential photon fields. The mathematical models compared were three commonly used parametric models [Lyman normal tissue complication probability (LNTCP), relative serialty (RS), generalized equivalent uniform dose (gEUD)] and a nonparametric model (Linear discriminant analysis--LDA). Data used by the models were the left ventricular dose--volume histograms, or SPECT-based dose-function histograms, and the presence/absence of SPECT perfusion defects 6 months postradiation therapy (21 patients developed defects). For the parametric models, maximum likelihood estimation and F-tests were used to fit the model parameters. The nonparametric LDA model step-wise selected features (volumes/function above dose levels) using a method based on receiver operating characteristics (ROC) analysis to best separate the groups with and without defects. Optimistic (upper bound) and pessimistic (lower bound) estimates of each model's predictive capability were generated using ROC curves. A higher area under the ROC curve indicates a more accurate model (a model that is always accurate has area = 1). The areas under these curves for different models were used to statistically test for differences between them. Pessimistic estimates of areas under the ROC curve using dose-volume histogram/ dose-function histogram inputs, in order of increasing prediction accuracy, were LNTCP (0.79/0.75), RS (0.80/0.77), gEUD (0.81/0.78), and LDA (0.84/0.86). Only the LDA model benefited from SPECT-based regional functional information. In general, the LDA model was statistically superior to the parametric models. The LDA model selected as features the left ventricular volumes above approximately 23 Gy (V23), essentially volume in field, and 33 Gy (V33), as best separating the groups with and without defects. In conclusion, the nonparametric LDA model appears to be a more accurate predictor of radiotherapy-induced left ventricular perfusion defects than commonly used parametric models.

Dose-Response Relationship, Radiation↗

Symptomatic cardiac events following radiation therapy for left-sided breast cancer: possible association with radiation therapy-induced changes in regional perfusion.

Our group has demonstrated that tangential radiation therapy (RT) to the left breast or chest wall can cause perfusion changes in the anterior myocardium. We assess if RT-induced perfusion changes are associated with the development of symptoms consistent with cardiac dysfunction. Between 1998 and 2001, 114 patients were enrolled into an institutional review board-approved prospective study and had pre-RT and serial post-RT (range, 6-24 months) single photon emission computed tomography (SPECT) scans to assess changes in regional cardiac perfusion. Thirty-one patients were excluded. The incidence of cardiac symptoms in patients with and without RT-induced perfusion defects was compared using a 2-tailed Fisher's exact test. With a median follow-up of 16 months (range, 6-24 months), 10 of 83 evaluable patients had > or = 1 episode of transient chest pain, occurring 0-14 months after RT (median, 6 months). The rates of chest pain in the patients with and without new perfusion defects were 9 of 31 and 1 of 52, respectively (P = 0.0004). A similar result was found when patients were segregated based on the use of chemotherapy. Two of these 10 cases were diagnosed as pericarditis. No patient had myocardial infarction or congestive heart failure. Cardiac symptoms occur more frequently in patients with perfusion abnormalities by SPECT after RT than in patients with normal SPECT scans, suggesting that such perfusion defects may be clinically significant. One confounding factor is that women who know they have RT-induced perfusion defects may be more likely to report episode of chest pain. Long-term follow-up will be necessary to better assess the clinical significance of RT-induced perfusion defects.

Breast Neoplasms↗

[Multicenter clinical trial on the efficacy of thrombolytic therapy with urokinase and/or anticoagulant with low molecular weight heparin in acute pulmonary embolism].

OBJECTIVE: To evaluate the efficacy of thrombolytic therapy with urokinase and/or anticoagulant with low molecular weight heparin in patients with acute pulmonary embolism. METHODS: 127 patients with documented acute pulmonary embolism were treated with different regimens: thrombolysis combined with anticoagulant therapy in 70 cases, thrombolytic therapy alone in 31 cases and pure anticoagulant therapy in 26 cases. RESULTS: Dyspnea was the most common symptom (91.3%), then cough (74.0%), chest pain (63.0%) and syncope (21.3%). As compared with pre-treatment in each group, there was significant improvement in respiratory rate, heart rate, partial pressure of oxygen in artery and partial pressure of carbon dioxide in artery. The effective rate of thrombolysis combined with anticoagulant therapy, thrombolytic therapy and anticoagulant therapy were 90.0%, 77.4% and 61.5%, respectively, the total effective rate of thrombolytic therapy was 86.1%. The best efficacy was demonstrated in patients within one week after onset of symptoms. The therapy might be effective for cases with duration longer than two weeks after the onset of symptoms. CONCLUSION: Thrombolytic therapy with urokinase combined with low molecular weight heparin is effective and safe for acute pulmonary embolism.

Adult↗