PubMed Health⌕ Search

Biomedical subjects

Suna Toksavul

Publications and source records attributed to Suna Toksavul.

10 recordsLinked to original sources

Effect of an antibacterial adhesive on the bond strength of three different luting resin composites.

OBJECTIVES: Effect of a dentin adhesive system containing antibacterial monomer-MDPB (Clearfil Protect Bond) on the shear bond strength of all-ceramic-IPS Empress 2 restorations luted with three different dual-polymerizing systems (Variolink 2, RelyX ARC and Panavia F 2.0) to dentin was investigated. METHODS: One hundred and eight all-ceramic discs (2 x 3mm; IPS Empress 2) were fabricated and ultrasonically cleaned. The buccal surfaces of 108 non-carious extracted human premolars were flattened to expose dentin and subsequently polished with 600-grit wet silicon carbide paper. Three dual-polymerizing luting systems had test groups and control groups consisting of 18 samples each. For the test groups Clearfil Protect Bond was applied to the exposed dentin surfaces. Control groups received the original bonding procedures of each adhesive system. After the all-ceramic samples were luted to the teeth, thermocycling was performed 5000 times. Shear bond strengths were tested using Shimadzu Universal Testing Machine until failure. Analysis of fractured dentin surfaces were performed using Optical Microscope at x10 and x1000 magnifications and the images were analyzed with Image Analyzer. Data was analyzed with one-way ANOVA and Bonferroni test at a significance level of p<0.05. RESULTS: Mean shear bond strength data of the groups in MPa were; Variolink: 20.45+/-4.75, Variolink+Clearfil Protect Bond:29.32+/-2.37, RelyX ARC:18.82+/-3.19, RelyX ARC+Clearfil Protect Bond:25.58+/-4.05, Panavia F 2.0:17.11+/-2.98, Panavia F 2.0+Clearfil Protect Bond:24.40+/-7.46. Application of the antibacterial adhesive increased the shear bond strengths of all three dual-polymerizing systems to dentin (p=0.00). The surface analysis showed that most of the specimens showed the adhesive failure mode between the dentin and the composite luting agent interface. CONCLUSION: The antibacterial adhesive system Clearfil Protect Bond can be safely used to prevent the potential risk of complications resulting from bacterial activity regardless of affecting the bond strength of IPS Empress 2 restorations luted with the dual-polimerizing systems used in this study.

Anti-Bacterial Agents↗

Esthetic enhancement of ceramic crowns with zirconia dowels and cores: a clinical report.

There has been an increase in the use of esthetic metal-free ceramic crowns in restoring endodontically treated teeth or teeth with severe coronal destruction. Tooth-colored dowels and cores are used to enhance the esthetic result. This report describes the treatment of a patient with bilateral maxillary supernumerary lateral incisors, a severe malocclusion, and maxillary anterior tooth discoloration. Treatment included heat-pressed, metal-free ceramic crowns supported by zirconia ceramic dowel-and-core foundations.

Adult↗

Amelogenesis imperfecta: the multidisciplinary approach. A case report.

Amelogenesis imperfecta is a hereditary developmental disorder of the dental enamel, in both primary and permanent dentition. The main clinical characteristics are extensive loss of tooth tissue, poor esthetics, and tooth sensitivity. Transmission of the gene takes place by either autosomal, dominant X-linked, or recessive modes. This clinical report describes a treatment sequence based on a multidisciplinary approach. A 21-year-old girl with hypoplastic amelogenesis imperfecta was referred to the Ege University School of Dentistry clinic. She was concerned about the poor appearance and sensitivity of her teeth. The patient presented with an anterior open bite, although orthodontic treatment had been completed previously. Periodontal gingivectomy of her posterior teeth followed by endodontic treatment where indicated was proposed. The prosthodontic treatment consisted of metal ceramic fixed partial dentures of precious alloy. At the end of treatment, function and esthetics were improved to a level acceptable to both the patient and the dental team.

Adult↗

Clinical application of all-ceramic fixed partial dentures and crowns.

The esthetic demands of patients have increased considerably during recent years. Due to this increasing interest in esthetics, as well as concerns about toxic and allergic reactions, the use of all-ceramic restorations has increased. One of the systems introduced for all-ceramic restorations is the IPS Empress system. This article examines one all-ceramic restoration system, IPS Empress, and presents patient cases in which all-ceramic crowns and fixed partial dentures have been utilized.

Adolescent↗

Intra-oral adhesive systems for ceramic repairs: a comparison.

The aim of this investigation was to compare the bond strength of restorative composite resin to dental ceramic conditioned with primers and adhesives of various commercial repair kits. Three intra-oral ceramic repair systems--Silistor (Heraeus Kulzer), Cimara (Voco), Ceramic Repair (Vivadent)--were used on all-ceramic (IPS Empress 2, Ivoclar-Vivadent) substrate. Shear bond strength of restorative composite resin to substrate was tested after thermocycling and without thermocycling (n = 10). Substrate surfaces of the specimen after loading were examined microscopically (SEM). The highest bond strengths in both water-stored (7.0 +/- 5.7 MPa) and thermocycled conditions (2.5 +/- 1.8 MPa) were obtained with the Vivadent repair system, while the lowest values were observed with the Cimara system (0.6 +/- 1.4 MPa and 0.0 +/- 0.0 MPa, respectively). Shear bond strengths appeared to be significantly affected by thermocycling (ANOVA, P < 0.05). It is concluded that there are significant differences in the bond strengths of resin composites and ceramic substrate. The roughened surface does not necessarily provide a better bond strength; the bond strength of composite decreases with storage in water and after thermocycling. Bond strength values were generally low for all of the tested materials.

Acrylates↗

Analysis of dentinal stress distribution of maxillary central incisors subjected to various post-and-core applications.

This study evaluated the stress distribution on an endodontically treated maxillary central incisor restored with different post-and-core systems by using a three-dimensional finite element analysis model. Seven three-dimensional finite element models were created. Each model contained cortical bone, cancelous bone, periodontal ligament, 3 mm apical root canal filling, post-and-core and all-ceramic crowns. Two different pre-fabricated zirconia ceramic post systems, a glass fiber-reinforced post system and a titanium post system were modeled. As a control, an all-ceramic crown on an endodontically treated maxillary central incisor without a post-and-core was modeled. Each model received a 45 degrees oblique occlusal load at a constant intensity of 100 N. In each model, the ratio of Von Mises stress distribution was compared. The greatest stresses were observed in the coronal third of the roots on facial surfaces. The ratio of Von Mises stress distribution in dentin for the zirconia ceramic post (CosmoPost) and ceramic core (Cosmo Ingot), zirconia ceramic post (CosmoPost) and composite core (Tetric Ceram), glass fiber-reinforced post (FRC Postec) and composite core (Tetric Ceram), titanium post (Er post) and composite core (Tetric Ceram), zirconia ceramic post (Cerapost) and ceramic core (Cosmo Ingot), zirconia ceramic post (Cerapost) and composite core (Tetric Ceram) and the control group were 0.886, 0.889, 0.988, 0.924, 0.889, 0.893 and 1, respectively. The stress concentrations in dentin created by two different zirconia ceramic post systems were nearly the same. The zirconia ceramic post systems created slightly less stress concentration in dentin than the glass fiber-reinforced and titanium posts.

Bite Force↗

Fracture resistance of five different metal framework designs for metal-ceramic restorations.

PURPOSE: This study evaluated fracture resistance of five different metal framework designs for metal-ceramic restorations. MATERIALS AND METHODS: Twenty-five artificial crowns were fabricated with different degrees of facial metal reduction: metal collar (group 1), and 0, 0.5, 1, and 1.5 mm (groups 2 to 5, respectively). All of the crowns were thermocycled in two different baths of 5 and 60 degrees C for 20 seconds and had a dwell time of 10 seconds in a resting bath at 37 degrees C for 510 cycles. The artificial crowns were then subjected to vertical loading until fracture with a Shimadzu testing machine at a cross-head speed of 1 mm/min. The load at fracture was recorded. RESULTS: There were no statistically significant differences between mean fracture strength of groups 1 and 2 or between groups 4 and 5. There were significant differences between group 3 and groups 1, 2, 4, and 5. CONCLUSION: As the amount of metal reduction increased, the vertical fracture resistance decreased. Failure loads for all test groups exceeded normal biting forces.

Analysis of Variance↗

Determination of elemental composition of substance lost following wear of all-ceramic materials.

PURPOSE: The aim of this study was to test the possible elemental release of four different all-ceramic materials in a wear machine to predict results about their long-term behavior in the oral environment. MATERIALS AND METHODS: Four different all-ceramic materials with different chemical compositions were selected for the wear testing. A total of 20 cylindric samples, five for each ceramic group, were prepared according to the manufacturers' instructions. These were subjected to two-body wear testing in an artificial saliva medium under a covered unit with a computer-operated wear machine. The artificial saliva solutions for each material were analyzed for the determination of amounts of sodium, potassium, calcium, magnesium, and lithium elements released from the glass-ceramic materials. The differences between and within groups were statistically analyzed with a one-way ANOVA, followed by Duncan tests. RESULTS: The statistical analyses revealed no significant differences among Na, K, Ca, or Mg levels (P > .05) released from the leucite-reinforced groups, while there was a significant (P < .05) increase in Li release from the lithium disilicate group. CONCLUSION: Considerable element release to the artifical saliva medium was demonstrated in short-term wear testing. The lithia-based ceramic was more prone to Li release when compared with other elements and materials.

Aluminum Silicates↗

Effects of dentin disinfectants on the shear bond strength of all-ceramics to dentin.

This study investigated the effect of dentin disinfectants on the shear bond strength of all-ceramic restorations luted with two different dual-polymerizing systems to dentin. Dentin disinfectants chlorhexidine gluconate-based Concepsis and benzalkonium chloride-based Tubulicid Red were applied in combination with Variolink 2 and Resilute. The buccal surfaces of non-carious extracted human premolars were flattened to expose dentin and subsequently polished with 600-grit wet silicon carbide paper. Each dual-polymerizing luting system had two test groups and a control group. Dentin from the test groups was first treated with dentin disinfectants, then the all-ceramic restorations were luted with dual polymerizing systems. The dentin without disinfectant application and ceramic restoration was used as a control. After the all-ceramic samples were luted to all treated surfaces, the specimens were thermocycled and tested for shear bond strength until failure. Analysis of the fractured dentin surfaces was performed using Optical Microscope-Nikon ECLIPSE ME 600 (Nikon Co, Tokyo, Japan) at between 10x and 1000x magnifications and the images were analyzed with Image Analyzer LUCIA 4.21 (Nikon Co). The data were analyzed with one-way ANOVA and Duncan test at a significance level of p<0.05. Application of the two dentin disinfectants increased the shear bond strength of both the Variolink 2 and Resilute systems, but this increase was statistically significant only in Tubulicid Red treated specimens (p<0.05). Surface analysis showed that all the specimens showed the adhesive failure mode between the dentin and composite luting agent interface.

Acid Etching, Dental↗