PubMed Health⌕ Search

Biomedical subjects

Sung In Jeong

Publications and source records attributed to Sung In Jeong.

6 recordsLinked to original sources

Tissue-engineered vascular grafts composed of marine collagen and PLGA fibers using pulsatile perfusion bioreactors.

Novel tubular scaffolds of marine source collagen and PLGA fibers were fabricated by freeze drying and electrospinning processes for vascular grafts. The hybrid scaffolds, composed of a porous collagen matrix and a fibrous PLGA layer, had an average pore size of 150+/-50 microm. The electrospun fibrous PLGA layer on the surface of a porous tubular collagen scaffold improved the mechanical strength of the collagen scaffolds in both the dry and wet states. Smooth muscle cells (SMCs)- and endothelial cells (ECs)-cultured collagen/PLGA scaffolds exhibited mechanical properties similar to collagen/PLGA scaffolds unseeded with cells, even after culturing for 23 days. The effect of a mechanical stimulation on the proliferation and phenotype of SMCs and ECs, cultured on collagen/PLGA scaffolds, was evaluated. The pulsatile perfusion system enhanced the SMCs and ECs proliferation. In addition, a significant cell alignment in a direction radial to the distending direction was observed in tissues exposed to radial distention, which is similar to the phenomenon of native vessel tissues in vivo. On the other hand, cells in tissues engineered in the static condition were randomly aligned. Immunochemical analyses showed that the expressions of SM alpha-actin, SM myosin heavy chain, EC von Willebrand factor, and EC nitric oxide were upregulated in tissues engineered under a mechano-active condition, compared to vessel tissues engineered in the static condition. These results indicated that the co-culturing of SMCs and ECs, using collagen/PLGA hybrid scaffolds under a pulsatile perfusion system, leads to the enhancement of vascular EC development, as well as the retention of the differentiated cell phenotype.

Animals↗

Mechano-active tissue engineering of vascular smooth muscle using pulsatile perfusion bioreactors and elastic PLCL scaffolds.

Blood vessels are subjected in vivo to mechanical forces in a form of radial distention, encompassing cyclic mechanical strain due to the pulsatile nature of blood flow. Vascular smooth muscle (VSM) tissues engineered in vitro with a conventional tissue engineering technique may not be functional, because vascular smooth muscle cells (VSMCs) cultured in vitro typically revert from a contractile phenotype to a synthetic phenotype. In this study, we hypothesized that pulsatile strain and shear stress stimulate VSM tissue development and induce VSMCs to retain the differentiated phenotype in VSM engineering in vitro. To test the hypothesis, rabbit aortic smooth muscle cells (SMCs) were seeded onto rubber-like elastic, three-dimensional PLCL [poly(lactide-co-caprolactone), 50:50] scaffolds and subjected to pulsatile strain and shear stress by culturing them in pulsatile perfusion bioreactors for up to 8 weeks. As control experiments, VSMCs were cultured on PLCL scaffolds statically. The pulsatile strain and shear stress enhanced the VSMCs proliferation and collagen production. In addition, a significant cell alignment in a direction radial to the distending direction was observed in VSM tissues exposed to radial distention, which is similar to that of native VSM tissues in vivo, whereas VSMs in VSM tissues engineered in the static condition randomly aligned. Importantly, the expression of SM alpha-actin, a differentiated phenotype of SMCs, was upregulated by 2.5-fold in VSM tissues engineered under the mechano-active condition, compared to VSM tissues engineered in the static condition. This study demonstrates that tissue engineering of VSM tissues in vitro by using pulsatile perfusion bioreactors and elastic PLCL scaffolds leads to the enhancement of tissue development and the retention of differentiated cell phenotype.

Animals↗

In vivo biocompatibilty and degradation behavior of elastic poly(L-lactide-co-epsilon-caprolactone) scaffolds.

Tubular scaffolds were fabricated from very elastic poly(L-lactide-co-epsilon-caprolactone) (PLCL, 50:50). The scaffolds were seeded with smooth muscle cells (SMCs) and implanted in nude mice to investigate the tissue compatibility and in vivo degradation behavior. Histological examination of all the implants with haematoxylin and eosin staining, masson trichrome staining, SM alpha-actin antibody, and CM-DiI labeling confirmed that the regular morphology and biofunction of the SMCs seeded and the expression of the vascular smooth muscle matrices in PLCL scaffolds. The implanted PLCL scaffolds displayed a slow degradation on time, where caprolactone units were faster degraded than lactide did. This could be explained by the fact that amorphous regions composed of mainly CL moieties degraded earlier than hard domains where most of the LA units were located. From these results, the scaffolds applied in this study were found to exhibit excellent tissue compatibility to SMCs and might be very useful for vascular tissue engineering.

Animals↗

Manufacture of elastic biodegradable PLCL scaffolds for mechano-active vascular tissue engineering.

A soft and very elastic poly(lactide-co-epsilon-caprolactone) (PLCL)(50:50, Mn 185 x 10(3)) was synthesized. Tubular scaffolds were prepared by an extrusion-particulate leaching method for mechano-active vascular tissue engineering. The copolymer was very flexible but completely rubber-like elastic. Even the high porous PLCL scaffolds (90% salt wt) exhibited 200% elongation, but recovery over 85% in a tensile test. Moreover, the PLCL scaffolds maintained their high elasticity also in culture media under cyclic mechanical strain conditions. The highly porous scaffold (90% salt wt) withstood for an initial 1 week without any deformation and sustained for 2 weeks in culture media under cyclic stress of 10% amplitude and at 1 Hz frequency which are similar to the natural vascular conditions. Vascular smooth muscle cells (VSMCs) were seeded on to the PLCL scaffolds. The cell adhesion and proliferation on the scaffolds of various pore-size were increased with increasing pore size. For the pore sizes of 50-100 microm, 100-150 microm, 150-200 microm and 200-250 microm, the ratios of cell numbers were about 1:1.2:1.9:2.2, respectively, at both 12 h and 5 days. Similarly, the higher porous scaffolds exhibited more cell adhesion and proliferation compared to lower porous one, where the effect was more pronounced in the longer proliferation period. SMC-seeded scaffolds were implanted subcutaneously in athymic nude mice to confirm the biocompatibility. Such a high elastic property and proper biocompatibility to SMCs of PLCL scaffolds prepared in this study will be very useful to engineer SM-containing tissues such as blood vessels under mechanically dynamic environments (mechano-active tissue engineering).

Animals↗

Elastic biodegradable poly(glycolide-co-caprolactone) scaffold for tissue engineering.

Cyclic mechanical strain has been demonstrated to enhance the development and function of engineered smooth muscle (SM) tissues, and it would be necessary for the development of the elastic scaffolds if one wishes to engineer SM tissues under cyclic mechanical loading. This study reports on the development of an elastic scaffold fabricated from a biodegradable polymer. Biodegradable poly(glycolide-co-caprolactone) (PGCL) copolymer was synthesized from glycolide and epsilon-caprolactone in the presence of stannous octoate as catalyst. The copolymer was characterized by (1)H-NMR, gel permeation chromatography and differential scanning calorimetry. Scaffolds for tissue engineering applications were fabricated from PGCL copolymer using the solvent-casting and particle-leaching technique. The PGCL scaffolds produced in this fashion had open pore structures (average pore size = 250 microm) without the usual nonporous skin layer on external surfaces. Mechanical testing revealed that PGCL scaffolds were far more elastic than poly(lactic-co-glycolic acid) (PLGA) scaffolds fabricated using the same method. Tensile mechanical tests indicated that PGCL scaffolds could withstand an extension of 250% without cracking, which was much higher than withstood by PLGA scaffolds (10-15%). In addition, PGCL scaffolds achieved recoveries exceeding 96% at applied extensions of up to 230%, whereas PLGA scaffolds failed (cracked) at an applied strain of 20%. Dynamic mechanical tests showed that the permanent deformation of the PGCL scaffolds in a dry condition produced was less than 4% of the applied strain, when an elongation of 20% at a frequency of 1 Hz (1 cycle per second) was applied for 6 days. Moreover, PGCL scaffolds in a buffer solution also had permanent deformations less than 5% of the applied strain when an elongation of 10% at a frequency of 1 Hz was applied for 2 days. The usefulness of the PGCL scaffolds was demonstrated by engineering SM tissues in vivo. This study shows that the elastic PGCL scaffolds produced in this study could be used to engineer SM-containing tissues (e.g. blood vessels and bladders) in mechanically dynamic environments.

Absorbable Implants↗

Morphology of elastic poly(L-lactide-co-epsilon-caprolactone) copolymers and in vitro and in vivo degradation behavior of their scaffolds.

Very elastic PLCL [poly(L-lactide-co-epsilon-caprolactone), 50:50] copolymers were synthesized and extruded into porous tubular scaffolds (pore size 150 +/- 50 microm, porosity 90%) for the application to tissue engineering. The copolymers were basically random and amorphous. However, two T(g)'s (glass transition temperatures) were observed in dynamic mechanical thermal analysis and also in differential scanning calorimetry thermograms. Furthermore, microdomains (about 17 nm in size) were indicated on the small-angle X-ray scattering profile and finally confirmed by transmission electron microscopy. Therefore, the PLCL copolymer was probably composed of a soft matrix of mainly epsilon-caprolactone moieties and hard domains containing more L-lactide units to exhibit a rubberlike elasticity in virtue of the physically cross-linked structure. The smooth muscle cells seeded scaffolds were implanted into nude mice subcutaneously for up to 15 weeks to monitor the in vivo degradation. In addition, they were degraded in vitro in phosphate buffer solution (pH 7.4) for up to 1 year to compare the results each other. All the scaffolds degraded slowly in vivo and in vitro even in the form of a highly porous thin membrane. However, the degradation rate was somewhat faster for in vivo than for in vitro. This should be explained by enzymes that might have played a certain role in the degradation in the body. In addition, the epsilon-caprolactone moieties degraded faster than the L-lactide units did in these PLCL scaffolds, although their hydrophilicities are in the opposite order. This behavior appeared more prominently in the in vivo case. This should result from that the amorphous regions composed of mainly epsilon-caprolactone units might have been first attacked by water because water can penetrate into the amorphous regions easier than the hard domains containing more L-lactides.

Animals↗