Publications and source records attributed to Sung Yang.

4 recordsLinked to original sources

A microfluidic device for continuous, real time blood plasma separation.

A microfluidic device for continuous, real time blood plasma separation is introduced. The principle of the blood plasma separation from blood cells is supported by the Zweifach-Fung effect and was experimentally demonstrated using simple microchannels. The blood plasma separation device is composed of a blood inlet, a bifurcating region which leads to a purified plasma outlet, and a concentrated blood cell outlet. It was designed to separate blood plasma from an initial blood sample of up to 45% inlet hematocrit (volume percentage of cells). The microfluidic network was designed using an analogous electrical circuit, as well as analytical and numerical studies. The functionality of this device was demonstrated using defibrinated sheep blood. During 30 minutes of continuous blood infusion through the device, all the erythrocytes (red blood cells) traveled through the device toward the concentrated blood outlet while only the plasma was separated at the bifurcating regions and flowed towards the plasma outlet. The device has been operated continuously without any clogging or hemolysis of cells. The experimentally determined plasma selectivity with respect to blood hematocrit level was almost 100% regardless of the inlet hematocrit. The total plasma separation volume percent varied from 15% to 25% with increasing inlet hematocrit. Due to the device's simple structure and control mechanism, this microdevice is expected to be used for highly efficient continuous, real time cell-free blood plasma separation from blood samples for use in lab on a chip applications.

Fluorescent Dyes↗

Design of a side-view particle imaging velocimetry flow system for cell-substrate adhesion studies.

Experimental models that mimic the flow conditions in microcapillaries have suggested that the local shear stresses and shear rates can mediate tumor cell and leukocyte arrest on the endothelium and subsequent sustained adhesion. However, further investigation has been limited by the lack of experimental models that allow quantitative measurement of the hydrodynamic environment over adherent cells. The purpose of this study was to develop a system capable of acquiring quantitative flow profiles over adherent cells. By combining the techniques of side-view imaging and particle image velocimetry (PIV), an in vitro model was constructed that is capable of obtaining quantitative flow data over cells adhering to the endothelium. The velocity over an adherent leukocyte was measured and the shear rate was calculated under low and high upstream wall shear. The microcapillary channel was modeled using computational fluid dynamics (CFD) and the calculated velocity profiles over cells under the low and high shear rates were compared to experimental results. The drag force applied to each cell by the fluid was then computed. This system provides a means for future study of the forces underlying adhesion by permitting characterization of the local hydrodynamic conditions over adherent cells.

Cell Adhesion↗

Blood plasma separation in microfluidic channels using flow rate control.

Several studies have clearly shown that cardiac surgery induces systemic inflammatory responses, particularly when cardiopulmonary bypass (CPB) is used. CPB induces complex inflammatory responses. Considerable evidence suggests that systemic inflammation causes many postoperative complications. Currently, there is no effective method to prevent this systemic inflammatory response syndrome in patients undergoing CPB. The ability to clinically intervene in inflammation, or even study the inflammatory response to CPB, is limited by the lack of timely measurements of inflammatory responses. In this study, a microfluidic device for continuous, real-time blood plasma separation, which may be integrated with downstream plasma analysis device, is introduced. This device is designed to have a whole blood inlet, a purified plasma outlet, and a concentrated blood cell outlet. The device is designed to separate plasma with up to 45% hematocrit of the inlet blood and is analyzed using computational fluid dynamics simulation. The simulation results show that 27% and 25% of plasma can be collected from the total inlet blood volume for 45% and 39% hematocrit, respectively. The device's functionality was demonstrated using defibrinated sheep blood (hematocrit=39%). During the experiment, all the blood cells traveled through the device toward the concentrated blood outlet while only the plasma flowed towards the plasma outlet without any clogging or lysis of cells. Because of its simple structure and control mechanism, this microdevice is expected to be used for highly efficient, realtime, continuous cell-free plasma separation.

Animals↗

Microfluidic devices for continuous blood plasma separation and analysis during pediatric cardiopulmonary bypass procedures.

As an extension of previous work, a microfluidic device, which can separate blood plasma in a continuous, real-time fashion from a whole blood, is successfully integrated with a mock cardiopulmonary bypass circuit. The functionality of the device is demonstrated with the use of freshly harvested bovine blood. The plasma selectivities were 100% and 99.4% and the plasma separation volume percents were 18.7% and 24.5% for 26% and 37% inlet hematocrit levels, respectively. As an advanced stage of this research, a microfluidic device, which can measure the concentration of clinically relevant blood plasma protein in a continuous fashion, is being developed on the basis of fluid handling circuits coupled to fluorescent cytometric bead assays. The functionality of the device is demonstrated with the use of a biotinylated FITC solution and a streptavidin-coated, 8-mum-diameter bead. The binding event between biotinylated FITC and the streptavidin bead is continuously detected within a detection window at the outlet of the device. For a known concentration (1 microg/ml) of biotinylated FITC solution, the measured fluorescent intensity is fairly constant and shows a stable gaussian distribution of the bead fluorescence intensity. It is expected that the proposed device can be used for continuous measurement of clinically relevant proteins during cardiac surgery with the cardiopulmonary bypass procedure.

Animals↗