PubMed Health⌕ Search

Biomedical subjects

Sungyong Jung

Publications and source records attributed to Sungyong Jung.

6 recordsLinked to original sources

Improved analysis on the viewing angle of integral imaging.

There have already been several analyses about the viewing angle of integral imaging (InIm). However, they can be applied only under the assumption that the original image is merely a single point source and are not suitable for application to an actual condition. We propose an improved analysis based on the actual InIm image, not on a single point source. It is possible to analyze and predict the viewing angle of an InIm system with good accuracy with the new analytic method because almost all the parameters of the InIm system such as the size and focal length of the lens array, image distance, the size and resolution of the image, and the location of the observers are included in this analysis.

Algorithms↗

Wide-viewing-angle integral three-dimensional imaging system by curving a screen and a lens array.

A wide-viewing-angle integral three-dimensional imaging system made by curving a screen and a lens array is described. A flexible screen and a curved lens array are incorporated into an integral imaging system in place of a conventional flat display panel and a flat lens array. One can effectively eliminate flipped images by adopting barriers. As a result, the implemented system permits the limitation of viewing angle to be overcome and the viewing angle to be expanded remarkably. Using the proposed method, we were able to achieve a viewing angle of 33 degrees (one side) for real integral imaging and 40 degrees (one side) for virtual integral imaging, which is four times wider than that of the currently used conventional techniques. The principle of the implemented system is explained, and some experimental results are presented.

Journal Article↗

Depth extraction by use of a rectangular lens array and one-dimensional elemental image modification.

Stereo matching, a technique for acquiring depth information from many planar images obtained by several cameras, was developed several decades ago. Recently a novel depth-extraction technique that uses a lens array instead of several cameras has attracted much attention because of the advantages offered by its compact system configuration. We present a novel depth-extraction method that uses a lens array consisting of vertically long rectangular lens elements. The proposed method rearranges the horizontal positions of the pixels from the collection of perspective images while it leaves the vertical positions of the pixels unchanged. To these rearranged images we apply a correlation-based multibaseline stereo algorithm in properly modified form. The main feature of the proposed method is the inverse dependency of the disparity in depth between horizontal and vertical directions. This inverse dependency permits the extraction of exact depth from extremely periodically patterned object scenes and reduces quantization error in the depth extraction.

Journal Article↗

Depth-enhanced integral imaging by use of optical path control.

The image depth of integral imaging is enhanced by doubling the number of central depth planes by use of optical path control. To accomplish this, the optical path lengths are changed by controlling whether reflections occur behind the lens array. We propose three schemes that use mirrors, a combination of beam splitters and polarizers, and polarization beam splitters, respectively. In experiments we implement the systems that are completely electronically controllable, are compact, and provide two central depth planes with 50.4-mm separation.

Journal Article↗

Wide-viewing integral three-dimensional imaging by use of orthogonal polarization switching.

A wide-viewing integral three-dimesional (3D) imaging system that adopts orthogonal polarization switching is proposed and demonstrated. In our scheme,the polarizing sheet attached to the lens array and the orthogonal polarization switching of the elemental image array perform elemental lens switching. The experimental results document that the viewing angle becomes remarkably wider than that of the conventional method. The distinguishing feature of our system is that it requires no mechanical moving part. In addition, because a commercially available polarization shutter screen is used for electrical switching, it is easy to implement this as a practical system. We believe that the proposed method facilitates the practical use of this wide-viewing integral 3D imaging system.

Journal Article↗

Viewing-angle-enhanced integral imaging by elemental image resizing and elemental lens switching.

Integral imaging (II) is one of the promising techniques in the field of autostereoscopic three-dimensional display. Despite of its many advantages, the narrow viewing angle has been a drawback. We propose a technique that enhances the viewing angle of II by resizing the elemental images taken by the pickup process and switching the elemental lenses in the display process. We explain the principle of the proposed technique, analyze the effect on the resolution of the integrated image, and show the experimental results.

Journal Article↗