PubMed Health⌕ Search

Biomedical subjects

Sunil S Solomon

Publications and source records attributed to Sunil S Solomon.

6 recordsLinked to original sources

Risk reduction counseling is associated with decreased HIV transmission-associated behaviors in high-risk Indian heterosexuals.

OBJECTIVE: To estimate the incidence of HIV and study the impact of risk-reduction counseling (RRC) in a cohort of people with high-risk behavior for HIV transmission in Chennai, India. DESIGN: Prospective cohort follow-up of 500 HIV-negative people (250 men and 250 women) at increased risk for HIV acquisition in Chennai, India for a maximum of 1 year was conducted. They received RRC at 0, 6, and 12 months. Generalized estimating equation methodology was used to determine the statistical significance of differences reported in behavior between baseline, 6 months, and 12 months. RESULTS: The overall HIV incidence in this cohort was 0.44 per 100 person-years (95% confidence interval: 0.05-1.60). In the course of the study, both male and female participants reported statistically significant decreases in the number of different sexual partners, the number of new partners, and the proportion of sexual encounters with nonprimary partners. Participants who had more than 3 different partners at baseline and/or exchanged money for sex in the 6 months before enrollment demonstrated the greatest reductions in the number of different sexual partners. CONCLUSIONS: Individualized sexual RRC seems to be a useful intervention to reduce risk-taking behavior among at-risk heterosexuals in India.

Adult↗

A reliable and inexpensive EasyCD4 assay for monitoring HIV-infected individuals in resource-limited settings.

Serial measurements of absolute CD4+ T-lymphocyte counts are required to initiate and gauge response to therapy and monitor disease progression. Hence, there is an urgent need to evaluate the accuracy and validity of low-cost CD4+ T-cell count assays. Tripotassium EDTA blood specimens from HIV-infected individuals were studied using a novel flow cytometric assay (EasyCD4 assay; Guava Technologies, Hayward, CA) in comparison with standard flow cytometry (FACSCount; Becton Dickinson Immunocytometry Systems, San Jose, CA). The sensitivity, specificity value by EasyCD4 assay in enumerating absolute CD4+ T-cell counts of less than 200 cells/microL were 95% and 100%, respectively. Bland-Altman analysis showed close agreement, with the EasyCD4 assay yielding CD4+ T-cell counts a mean difference of -26 cells/microL (95% confidence interval, -96 to 44 cells/microL) higher than by flow cytometry. Our data suggest that EasyCD4 assay could be a useful alternative assay to conventional flow cytometry, may be appropriate for use in resource-limited settings.

Adolescent↗

The efficacy of sirolimus- and paclitaxel-eluting stents: a meta-analysis of randomized controlled trials.

BACKGROUND: Drug-eluting stents prevent in-stent restenosis after percutaneous coronary intervention, and differences between sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) may exist in the rates of target lesion revascularization, death, myocardial infarction and stent thrombosis. OBJECTIVE: To compare the efficacy of SES and PES with the efficacy of bare-metal stents for de novo coronary lesions in patients with stable or unstable angina. METHODS: A meta-analysis of randomized trials from MEDLINE, EMBASE and other electronic databases and conference proceedings was conducted. The efficacy of SES, PES with a polymer carrier (PPOL) and PES without a polymer carrier (PNPOL) was compared using random-effects models. RESULTS: Ten trials comprising 5041 patients were included in the meta-analysis. There was an absolute decrease in target lesion revascularization of 17% (95% CI 14% to 20%), 9% (95% CI 6% to 11%) and 3% (95% CI 0% to 6%) with SES, PPOL and PNPOL, respectively, with significant differences between SES and PPOL and between PPOL and PNPOL (P < 0.01 for both comparisons). However, sensitivity analysis using the OR of target lesion revascularization showed no difference between SES (OR 0.18 [95% CI 0.12 to 0.26]) and PPOL (OR 0.25 [95% CI 0.16 to 0.37]) (P = 0.26). There were no differences in the incidence of death, myocardial infarction or stent thrombosis, although the small number of events limited the power of these analyses. CONCLUSIONS: SES show a greater absolute reduction in target lesion revascularization than do PES, likely due to differences in the bare-metal stents used for comparison in the trials. Head-to-head comparisons are needed to directly address the differential efficacy of SES and PES.

Age Factors↗

HIV-1 western blot assay: What determines an indeterminate status?

BACKGROUND: The Western blot assay is the gold standard for the detection of antibodies to human immunodeficiency virus type 1 (HIV-1). However, indeterminate Western blot reactivity to HIV-1 proteins may occur in individuals, who may not be infected with HIV. AIM: This retrospective study was aimed to determine the diagnostic value of the interpretation criteria in relation to commercial kits for HIV-1 diagnosis. METHODS AND MATERIALS: A total of 556 serum/plasma specimens collected from high-risk population attending our HIV clinic from 2000-2004 were tested by three different western blot kits: NEW LAV BLOT I (n=244), HIV BLOT 2.2; (n=112), Genetic Systems HIV-1 (n=237). And the results of western blot strips were analyzed using the various interpretation criteria: WHO/NACO, CDC/ ASTPHLD, ARC, FDA, CRSS and JHU. Some specimens were run on more than one kit. RT-PCR assay was performed on 5 specimens, which were indeterminate with LAV BLOT I. RESULTS: The discrepancy in LAV BLOT I positive results were between 157(64)-176(72), and indeterminate results were between 44(18) to 63(25). No such variations were observed in genetic systems. There are some HIV negative (by PCR) specimens were indeterminate in LAV BLOT I revealing the kit more sensitive and less effective for diagnostic purpose. CONCLUSION: The genetic systems kit is superior to other kits we analyzed and its results are concordant with HIV-1 PCR results. To report, the choice of western blot commercial kit is paramount important than the use of particular interpretation criteria for the diagnosis of HIV-1.

Blotting, Western↗

Dried blood spots (DBS): a valuable tool for HIV surveillance in developing/tropical countries.

Dried blood spots (DBS) on filter paper have been used as a practical method of sample collection in sero-surveillance studies of numerous diseases. DBS may be particularly useful for HIV screening in remote areas, in which unrefrigerated transfer time to a laboratory may take a number of days. In this study, we evaluate the ability to detect human immunodeficiency virus (HIV) type-1 antibodies from DBS that have been subjected to a tropical climate in southern India for 6 days. DBS were prepared from blood samples of 59 known HIV-positive individuals and 30 known HIV-negative individuals. ELISA and Western blot results from DBS that were subjected to a mean temperature of 35.8 degrees C and humidity of 73% for 6 days had a sensitivity of 100% and 92%, respectively, and a specificity of 100% and 100%, respectively. Based on these findings, we conclude that DBS sampling could serve as a cost-effective and convenient tool for widespread HIV sero-surveillance in remote areas within tropical countries.

AIDS Serodiagnosis↗