PubMed Health⌕ Search

Biomedical subjects

Sunita Chauhan

Publications and source records attributed to Sunita Chauhan.

2 recordsLinked to original sources

Phonocardiographic signal analysis method using a modified hidden Markov model.

Auscultation is an important diagnostic indicator for cardiovascular analysis. Heart sound classification and analysis play an important role in the auscultative diagnosis. This study uses a combination of Mel-frequency cepstral coefficient (MFCC) and hidden Markov model (HMM) to efficiently extract the features for pre-processed heart sound cycles for the purpose of classification. A system was developed for the interpretation of heart sounds acquired by phonocardiography using pattern recognition. The task of feature extraction was performed using three methods: time-domain feature, short-time Fourier transforms (STFT) and MFCC. The performances of these feature extraction methods were then compared. The results demonstrated that the proposed method using MFCC yielded improved interpretative information. Following the feature extraction, an automatic classification process was performed using HMM. Satisfactory classification results (sensitivity > or =0.952; specificity > or =0.953) were achieved for normal subjects and those with various murmur characteristics. These results were based on 1398 datasets obtained from 41 recruited subjects and downloaded from a public domain. Constituents characteristics of heart sounds were also evaluated using the proposed system. The findings herein suggest that the described system may have the potential to be used to assist doctors for a more objective diagnosis.

Data Interpretation, Statistical↗

Multiple high-intensity focused ultrasound probes for kidney-tissue ablation.

BACKGROUND AND PURPOSE: To investigate kidney-tissue ablation by high-intensity focused ultrasound (HIFU) using multiple and single probes. MATERIALS AND METHODS: Ultrasound beams (1.75 MHz) produced by a piezoceramic element (focal distance 80 mm) were focused at the center of renal parenchyma. One of the three probes (mounted on a jig) could also be used for comparison with a single probe at comparable power ratings. Lesion dimensions were examined in perfused and unperfused ex vivo porcine kidneys at different power levels (40, 60, and 80 W) and treatment times (4, 6, and 8 seconds). RESULTS: At identical power levels, the lesions induced by multiple probes were larger than those induced by a single probe. Lesion size increased with increasing pulse duration and generator power. The sizes and shapes of the lesions were predictably repeatable in all samples. Lesions in perfused kidneys were smaller than those in unperfused kidneys. CONCLUSIONS: Ex vivo, kidney-tissue ablation by means of multiple HIFU probes offers significant advantages over single HIFU probes in respect of lesion size and formation. These advantages need to be confirmed by tests in vivo at higher energy levels.

Animals↗