Postoperative opacification of the peripheral optic region and haptics of a hydrophilic acrylic intraocular lens: case report and clinicopathologic correlation.

We report the first case of opacification of the BioComFold 92S (Morcher GmbH) intraocular lens. The opacification pattern is unique, presenting mainly in the periphery of the optic and the haptics of the lens, leaving the central portion of the optic clear. The clinical course of this opacification pattern is not observed typically with other hydrophilic acrylic lens designs and requires further study.

Aged↗

Irregularities on the surface of single-piece AcrySof SA60AT intraocular lenses.

PURPOSE: To report a case series of what initially appeared to be macroscopic biomaterial deposits and irregularities on the surface of AcrySof SA60AT intraocular lenses (IOLs) (Alcon Inc.) SETTING: Department of Ophthalmology and Somerset Hospital, Taunton, United Kingdom; Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, Utah, USA; and Intraocular Implant Unit, Sydney Eye Hospital, University of Sydney, Sydney, Australia. METHODS: Twelve AcrySof SA60AT IOLs were initially thought to have irregularities on their surfaces when examined under the operating microscope before implantation in the capsular bag during cataract surgery. The IOLs were sent for further analysis, including gross examination and light and scanning electron microscopy, to John A. Moran Eye Center, Salt Lake City, Utah, USA, and to Alcon Laboratories, Hemel Hempstead, United Kingdom. RESULTS: Light microscopy revealed the presence of irregular fine lesions on the IOLs' optics and haptics. The lesions consisted of elevations and depressions of the IOL surface that were present on both the anterior and the posterior surfaces of the IOLs. Scanning electron microscopy confirmed the presence of physical/mechanical damage to the IOLs, which was thought to originate from the packaging. The manufacturer believed this to have resulted from compression of the IOL between the container and its cover. CONCLUSIONS: Implantation of an imperfect IOL remains a potentially serious occurrence. Faults still occur in modern IOLs, and some defects can be detected by examining the IOL under the operating microscope before implantation into the eye.

Acrylic Resins↗

Two opacification patterns of the same hydrophilic acrylic polymer: case reports and clinicopathological correlation.

We report 2 intraocular lenses (IOLs) manufactured from the same hydrophilic acrylic polymer by Ioltech that developed optic opacification. In both cases, the postoperative course after implantation of the IOLs was complicated by significant inflammatory reaction with fibrin formation in the anterior chamber. Pathologic analyses of the explanted IOLs were consistent with dystrophic calcification leading to optic opacification, but the pattern was different between the 2 IOL designs. Patient-related factors might have been responsible for this complication.

Acrylic Resins↗

Postoperative surface deposits on intraocular lenses in children.

PURPOSE: To report the clinicopathologic features of 4 intraocular lenses (IOLs) composed of 3 different hydrophilic biomaterials explanted from children who had postoperative opacification of the IOL optic. SETTING: David J Apple, MD, Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. METHODS: The IOLs were explanted 20, 11, 22, and 25 months postoperatively from children aged 10, 3, 36, and 20 months old, respectively, at IOL implantation. Clinical data were obtained to correlate the findings with possible associated risk factors. The explanted IOLs were examined by gross and light microscopy. They were further analyzed with a stain for calcium, alizarin red 1%. Scanning electron microscopy and energy dispersive X-ray spectroscopy (EDS) were also performed. RESULTS: The primary reason for cataract surgery in Case 1 and Case 2 was persistent hyperplastic primary vitreous (PHPV); 1 patient received a B-Lens IOL (Hanita) and the other a Centerflex IOL (Rayner). The primary reason in Case 3 was familial bilateral congenital cataract and in Case 4, rubella cataract; both patients received a Hydroview IOL (Bausch & Lomb). All 4 IOLs had surface deposits on the optic, but the morphology of the deposits on the B-Lens and Centerflex IOLs was different than that in previously reported cases. The deposits in all four cases stained positive with alizarin red and consisted of calcium and phosphorus when imaged with EDS. CONCLUSIONS: Calcified deposits on 2 Hydroview IOLs explanted from children were similar to those seen in adults with the same IOL. The deposits on the B-Lens and Centerflex IOLs were probably secondary to a breakdown of the blood-aqueous barrier caused by preexisting PHPV.

Anthraquinones↗

Multimodality agents for tumor imaging (PET, fluorescence) and photodynamic therapy. A possible "see and treat" approach.

Methyl 3-(1'-m-iodobenzyloxyethyl)-3-devinylpyropheophorbide-a (2), obtained in a sequence of reactions from pyropheophorbide-a (a chlorophyll-a derivative), was found to be a promising imaging agent and a photosensitizer for photodynamic therapy (PDT). The electrophilic aromatic iodination of the corresponding trimethylstannyl intermediate with Na124I in the presence of an Iodogen bead afforded 124I-labeled photosensitizer 4 with >95% radioactive specificity. In addition to drug-uptake, the light fluence and fluence rate that were used for the light treatment had a significant impact in long-term tumor cure. The iodo photosensitizer 2 (nonlabeled analogue of 4) produced 100% tumor cure (5/5 mice were tumor free on day 60) at a dose of 1.5 micromol/kg and a light dose of 128 J/cm2, 14 mW/cm2 for 2.5 h (lambda(max) 665 nm) at 24 h postinjection. The photosensitizer also showed promising tumor fluorescence and PET imaging ability. Our present work demonstrates the utility of the first 124I-labeled photosensitizer as a "multimodality agent", which could further be improved by using more tumor-avid and/or target-specific photosensitizers.

Animals↗

Selective death of lens epithelial cells using demineralized water and Triton X-100 with PerfectCapsule sealed capsule irrigation: a histological study in rabbit eyes.

BACKGROUND: Sealed irrigation of the capsular bag after removal of the cataractous lens isolates the interior of the capsular bag from the anterior segment, permitting isolated targeting of lens epithelial cells (LECs) in vivo using pharmacologic agents while minimizing the risk of damage to other intraocular structures. OBJECTIVES: To assess the ability to deliver a nonspecific, extremely toxic agent (Triton X-100) directly to the LECs after crystalline lens removal, and to assess the eyes histologically for evidence of collateral damage. METHODS: Twelve eyes from 6 New Zealand White rabbits were divided into 3 groups of 4 eyes that underwent phacoaspiration of the crystalline lens. Group 1 was a control. In group 2, the anterior segment was irrigated with Triton X-100 and demineralized water for injection for 5 minutes. In group 3, the lens capsule was isolated from the anterior segment using sealed capsule irrigation (SCI) with PerfectCapsule (Milvella Pty Ltd, Sydney, Australia). After surgery, the rabbits were humanely euthanized. The enucleated eyes were immediately fixed in 10% neutral buffered formalin, histological analysis was performed to assess the corneal endothelium, iris, and retina, and the capsular bag and residual equatorial LECs were assessed. RESULTS: The capsular bag was sealed and inflated under SCI in all treated eyes in group 3. Histological evaluation revealed no evidence of collateral damage in group 1 and group 3. Significant histological damage to the cornea, iris, and peripheral retina was noted in group 2. Histological evaluation of each capsular bag suggests presence of LECs in group 1 and group 2. In the presence of SCI, Triton X-100 caused almost complete destruction of LECs in the capsular bag. CONCLUSIONS: Results suggest that SCI allows selective delivery of toxic agents directly into the capsular bag, preventing collateral damage to surrounding intraocular structures. The PerfectCapsule device kept the capsular bag well inflated intraoperatively, which may allow the isolated, safe delivery of pharmacologic agents into the capsular bag during cataract surgery. Clinical Relevance Postoperative proliferation of LECs in the capsular bag remains the most frequent complication of cataract surgery. Unprotected intraocular infusion of cytotoxic drugs, antimetabolites, or hypo-osmotic agents during cataract surgery has the potential risk of causing toxic effects in corneal endothelium and adjacent intraocular tissues. Selective delivery of pharmacologic/hypo-osmotic agents into the capsular bag requires positive pressure inflation of the bag and is now possible using an SCI device. This device allows the surgeon to reseal the capsular bag intraoperatively, achieve positive pressure inflation of the capsular bag, and direct selective targeting of LECs.

Animals↗

Posterior capsule opacification in rabbit eyes implanted with 1-piece and 3-piece hydrophobic acrylic intraocular lenses.

PURPOSE: To evaluate the outcome of posterior capsule opacification (PCO) after implantation in rabbit eyes of currently available 3-piece and 1-piece hydrophobic acrylic intraocular lenses (IOLs) with square optic edges. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: The 3-piece designs evaluated were the AR40e (Advanced Medical Optics Inc.) and the MA60AC (Alcon, Inc.); the 1-piece designs were the SA60AT and the SA30AT (Alcon, Inc.). Nine lenses of each type were implanted in a randomized manner by the same surgeon in 18 Dutch Belted pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and analyses of the enucleated eyes were performed from the posterior or Miyake-Apple view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was scored from 0 to 4. The area of Soemmering's ring formation was also scored from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL anterior surface, IOL centration, fixation, and presence of striae. Results from the posterior view were complemented by histopathologic evaluation of the eyes. RESULTS: No statistically significant difference was found between the 4 groups of IOLs in the parameters analyzed from the posterior view. When cell ingrowth occurred with the 1-piece designs, causing peripheral and central PCO formation, it was more likely to start at the optic-haptic junctions, as observed during the clinical follow-up with slitlamp examination and confirmed by gross and histopathologic analyses of the enucleated eyes. CONCLUSIONS: The square, truncated optic edge is the most important IOL design feature for PCO prevention. The optic-haptic junctions of the 1-piece designs appear to be sites where the barrier effect of the truncated optic edge is less effective.

Acrylic Resins↗

Evaluation of the cataractogenic effect of viscoanesthetic solutions on the rabbit crystalline lens.

PURPOSE: To evaluate the toxicity and cataractogenic effect of solutions combining sodium (Na) hyaluronate 1.0% and 1.5% with lidocaine 1.0% on the rabbit crystalline lens. The amount of pupil dilation provided by the addition of lidocaine to the Na hyaluronate solutions was also assessed. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Five solutions were injected into the anterior chamber of 18 pigmented rabbits in a randomized manner by the same surgeon, the intraocular component of VisThesia (Na hyaluronate 1.5%/lidocaine 1.0%), the intraocular component of VisThesia Light (Na hyaluronate 1.0%/lidocaine 1.0%), Ophthalin Plus (Na hyaluronate 1.5%), and a balanced salt solution; and both eyes of 2 other rabbits were injected with nonpreserved aqueous lidocaine 1.0%. The pupil diameter of each eye was measured before injection, immediately after, and 1 and 5 minutes after injection. After a follow-up of 3 months with slitlamp examinations, the rabbits were killed, and their eyes were enucleated. The crystalline lenses were evaluated from a posterior or Miyake-Apple view, and the eyes were fixated in 10% formalin for histopathologic analyses. RESULTS: Pupil diameter was significantly larger 1 and 5 minutes after injection in the VisThesia (P = .01 and P = .007) and VisThesia Light (P = .008 and P = .007) groups, whereas the differences were not significant in the Ophthalin Plus (P = .317 and P = .102) and balanced salt solution groups (P = .317 and P = .180). Fast and large pupillary dilation was observed in the aqueous lidocaine group, starting during the injection. No differences in the transparency of the natural lens and the red fundus reflex were noted during slitlamp examinations. Postmortem analyses from a posterior view also showed no differences in the transparency of the crystalline lens. The histopathologic appearance of the lens capsule, anterior and equatorial lens epithelial cells, and epithelial lens bow was comparable in the eyes, without signs of cell vacuolization or disruption. CONCLUSIONS: Intracameral injection of the solutions used in this study caused no localized opacity or overall change in the transparency of the crystalline lenses as observed during clinical and postmortem examinations as well as histopathologic analyses of the enucleated rabbit eyes. Viscoanesthesia may have application in phakic intraocular lens implantation.

Anesthetics, Local↗

Cocooning of an iris-fixated intraocular lens in a 3-year-old child after perforating injury: clinicopathologic correlation.

We present a 3-year-old patient who developed extensive noninflammatory fibrous membrane formation in the anterior chamber involving the present iris-fixated intraocular lens (IOL), with subsequent need for explantation. The child had had repair of a corneal injury, crystalline lens extraction and Artisan iris-claw IOL (Ophthec) implantation after a penetrating injury 2 months before. Histopathologic analyses were consistent with a retrocorneal membrane that originated from the corneal stroma and formed a "cocoon" membrane on the iris-claw IOL.

Anterior Chamber↗

Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

Cornea↗

Functionalization of OEP-based benzochlorins to develop carbohydrate-conjugated photosensitizers. Attempt to target beta-galactoside-recognized proteins.

meso-(2-Formylvinyl)octaethylporphyrin on reaction with cyanotrimethylsilane in the presence of various catalysts [copper triflate [Cu(OTf)(2)], indium triflate [In(OTf)(3)], or magnesium bromide diethyl etherate (MgBr(2).Et(2)O)] produced a mixture of the intermediate 3-hydroxy-3-cyanopropenoporphyrin, the corresponding trimethylsilyl ether derivative, and the unexpected propenochlorins. The yields of the reaction products were found to depend on the reaction conditions and the catalysts used. The intermediate porphyrins on treatment with concentrated sulfuric acid yielded the free-base cyanobenzochlorins in major quantity along with several other novel benzochlorins as minor products. Reduction of ethyl-3-hydroxy-1-pentenoate-porphyrin with DIBAL-H/NaBH(4) and subsequent acid treatment provided the corresponding free-base 10(3)-(2-hydroxyethyl)benzochlorin, which upon a sequence of reactions gave a free-base benzochlorin bearing a carboxylic acid functionality in good yield. It was then condensed with a variety of carbohydrates (glucosamine, galactosamine, and lactosamine), and the related conjugates were screened using the galectin-binding-ability assay. Among the carbohydrate conjugates investigated, the lactose and galactose analogues displayed the galectin-binding ability with an enhancement of about 300-400-fold compared to lactose. In preliminary studies, all photosensitizers (with or without carbohydrate moieties) were found to be active in vitro [radiation-induced fibrosarcoma (RIF) tumor cells]. However, the cells incubated with lactose (known to bind to beta-galactoside-recognized proteins) prior to the addition of the photosensitizers containing the beta-galactose moiety (e.g., galactose and lactose) produced a 100% decrease in their photosensitizing efficacy. Under similar experimental conditions, benzochlorin without a beta-galactoside moiety or the related glucose conjugate did not show any inhibition in its photosensitizing efficacy. These results in combination with the galectin-binding data indicate a possible beta-galactoside-recognized protein specificity of the galactose- and lactose-benzochlorin conjugates.

Carbohydrates↗

Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes.

PURPOSE: To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. RESULTS: The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. CONCLUSIONS: The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.

Animals↗

Single-piece hydrophobic acrylic intraocular lens explanted within the capsular bag: case report with clinicopathological correlation.

A 74-year-old woman had uneventful phacoemulsification with implantation of a single-piece hydrophobic acrylic intraocular lens (IOL) (SA30AL) in her left eye. Two weeks after the surgery, the patient presented for ophthalmological consultation reporting pseudophakic dysphotopsia, which she had subjectively noted since surgery. Explantation/exchange of the IOL was performed 3 months after the surgery. The IOL was strongly attached to the capsule, which was fibrotic and contracted; explantation of the capsular bag complex in toto was done. To our knowledge, this is the first case of explantation of this IOL design with clinicopathological correlation.

Aged↗

Correlation between different measurements within the eye relative to phakic intraocular lens implantation.

PURPOSE: To obtain measurements of the white-to-white distance and the anterior chamber and ciliary sulcus diameters in phakic human eyes obtained post-mortem to find a correlation between these measurements. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Twenty-two phakic human eyes obtained from eye banks within 24 hours of death were evaluated. The following measurements were performed: white-to-white distance, anterior chamber diameter with a plastic sizer after a small limbal incision, and anterior chamber and ciliary sulcus diameters after fixation and sagittal section of the eyes. The first 10 eyes were studied at the 6 o'clock to 12 o'clock meridian and the last 12 eyes, at the 3 o'clock to 9 o'clock meridian. RESULTS: A positive correlation was found between the white-to-white measurements and the anterior chamber diameter in the 10 eyes studied at the 6 o'clock to 12 o'clock meridian but not in the 12 eyes studied at the 3 o'clock to 9 o'clock meridian. The latter is the meridian frequently used by surgeons to perform white-to-white measurements and thus choose the overall size of the phakic intraocular lens to be implanted. No correlation was found between the white-to-white measurements and the ciliary sulcus diameter in the 2 meridians. CONCLUSION: Experimental studies using cadaver eyes are helpful in evaluating sizing techniques for phakic IOL implantation as well as in better understanding the anatomical relationships between ocular structures.

Aged↗

Pathological evaluation of postmortem human eyes implanted with a new single-piece hydrophobic acrylic lens.

PURPOSE: To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. RESULTS: All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. CONCLUSIONS: Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.

Anterior Eye Segment↗

Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation: experimental study in pediatric human eyes.

PURPOSE: To compare the amount of capsulorhexis ovaling and capsular bag stretch produced by various intraocular lenses (IOLs) implanted in pediatric human eyes obtained post-mortem. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: In this nonrandomized comparative study, 16 pediatric human eyes obtained postmortem were divided into 2 groups: Eight eyes were obtained from children younger than 2 years (Group A), and 8 eyes were obtained from children older than 2 years (Group B). All eyes were prepared according to the Miyake-Apple posterior video technique. Six types of rigid and foldable posterior chamber IOLs manufactured from poly(methyl methacrylate) (single-piece), silicone (plate and loop haptics), and hydrophobic acrylic (single-piece and 3-piece AcrySof, Alcon Laboratories) biomaterials were implanted. The capsulorhexis opening and capsular bag diameters were measured before IOL implantation and after in-the-bag IOL fixation with the haptics (or the main axis) at the 3 to 9 o'clock meridian. The percentage of ovaling of the capsulorhexis opening was calculated by noting the difference in the opening's horizontal diameter before and after IOL implantation. The percentage of capsular bag stretch was also calculated by noting the difference in the horizontal capsular bag diameter before and after IOL implantation. RESULTS: All IOLs produced ovaling of the capsulorhexis opening and stretching of the capsular bag parallel to the IOL haptics. There were significant differences in capsulorhexis ovaling and capsular bag stretch (P<.001, analysis of variance) between the 6 IOL types in each group of eyes. The postimplantation difference was significant only between the single-piece hydrophobic acrylic IOL (AcrySof) and the other IOLs. The single-piece hydrophobic acrylic IOL was associated with significantly less capsulorhexis ovaling and capsular bag stretch in both groups (mean 12.06% +/- 0.59% [SD] and 7.6% +/- 1.47%, respectively). CONCLUSIONS: Modern rigid and foldable IOLs designed for the adult population implanted in the capsular bag of infants and children produced variable degrees of capsulorhexis ovaling and capsular bag stretch. The Miyake-Apple posterior video technique confirmed the well-maintained configuration of the capsular bag (with minimal ovaling) after implantation of a single-piece hydrophobic acrylic IOL because of its flexible haptic design.

Capsulorhexis↗

Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge.

PURPOSE: To evaluate the development of posterior capsule opacification (PCO) after implantation of single-piece hydrophilic acrylic intraocular lenses (IOLs) with an enhanced square edge. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: The standard 570H Centerflex (Rayner Ltd.) design was compared to 2 new designs with enhanced square edges: the 570E and the 570C. Ten IOLs of each type were implanted in a randomized manner by the same surgeon in 15 pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and the eyes were analyzed from the posterior view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was graded from 0 to 4. The area of Soemmering's ring was graded from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL edge and IOL centration and fixation. Results from the posterior view were complemented by histopathological evaluation. RESULTS: Posterior capsule opacification was lowest in the 570C group, highest in the 570H group, and intermediate in the 570E group. There was a statistically significant difference between the 3 groups in peripheral PCO (P = .039). No significant difference was found between the groups in the other parameters analyzed. When cell ingrowth occurred with the 570H, it started at the optic-haptic junctions, as observed during the clinical follow-up and confirmed by gross and histopathological analyses. CONCLUSIONS: The square optic edge is the most important IOL design feature for PCO prevention. However, it should be present for 360 degrees around the IOL optic to provide an effective barrier effect.

Acrylic Resins↗

Analysis of the capsule edge after Fugo plasma blade capsulotomy, continuous curvilinear capsulorhexis, and can-opener capsulotomy.

PURPOSE: To compare the quality of the edges of anterior capsulotomies performed in porcine eyes using 3 different techniques. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. METHODS: Four porcine eyes were submitted to the center in 10% neutral buffered formalin. The cornea of the eyes had been removed, and a continuous capsulotomy had been performed in each eye using the Fugo plasma blade. To provide morphologic correlation, 4 additional porcine eyes were used in the study. In 2, a manual continuous curvilinear capsulorhexis (CCC) was performed after the cornea or cornea/iris was removed and in the other 2, a can-opener capsulotomy (COC) was performed. The eyes were then placed in 10% neutral buffered formalin. Gross (macroscopic) and microscopic analysis of each eye was performed, and photographs were taken. One eye in each group was also prepared and analyzed under scanning electron microscopy (SEM). RESULTS: The capsulotomy margin in the Fugo blade group presented some regularly spaced tags directed centrally with smooth edges at the base. Such a configuration would not interfere with the dynamics of the capsulorhexis sphincter and would generally not lead to radial tears. The smooth and regular nature of the capsulotomy margin in the CCC group was confirmed by gross and microscopic examinations of the eyes. The capsulotomy margin in the COC group presented some sharp notches directed outward, irregularly spaced, and irregular in shape. These are known to have a tendency to extend and form radial tears. CONCLUSION: Although performance of an anterior capsulotomy with the Fugo blade was associated with some margin irregularities, the geometry of the centrally directed tags prevented them from becoming the site of radial tear formation. The base of the capsulotomy performed with the Fugo blade appeared to be almost as smooth and regular as in the CCC under SEM evaluation.

Animals↗