PubMed Health⌕ Search

Biomedical subjects

Susan A Small

Publications and source records attributed to Susan A Small.

5 recordsLinked to original sources

Effects of bone oscillator coupling method, placement location, and occlusion on bone-conduction auditory steady-state responses in infants.

OBJECTIVE: The aim of these experiments was to investigate procedures used when estimating bone-conduction thresholds in infants. The objectives were: (i) to investigate the variability in force applied using two common bone-oscillator coupling methods and to determine whether coupling method affects threshold estimation, (ii) to examine effects of bone-oscillator placement on bone-conduction ASSR thresholds, and (iii) to determine whether the occlusion effect is present in infants by comparing bone-conduction ASSR thresholds for unoccluded and occluded ears. DESIGN: Experiment 1A: The variability in the amount of force applied to the bone oscillator by trained assistants (n = 4) for elastic-band and hand-held coupling methods was measured. Experiment 1B: Bone-conduction behavioral thresholds in 10 adults were compared for two coupling methods. Experiment 1C: ASSR thresholds and amplitudes to multiple bone-conduction stimuli were compared in 10 infants (mean age: 17 wk) using two coupling methods. Experiment 2: Bone-conduction ASSR thresholds and amplitudes were compared for temporal, mastoid and forehead oscillator placements in 15 preterm infants (mean age: 35 wk postconceptual age (PCA)). Experiment 3: Bone-conduction ASSR thresholds, amplitudes and phase delays were compared in 13 infants (mean age: 15 wk) for an unoccluded and occluded test ear. All infants that participated had passed a hearing screening test. RESULTS: Experiment 1A: Coupling method did not significantly affect the variability in force applied to the oscillator. Experiment 1B: There were no differences in adult bone-conduction behavioural thresholds between coupling methods. Experiment 1C: There was no significant difference between oscillator coupling method or significant frequency x coupling method interaction for ASSR thresholds or amplitudes in the young infants tested. However, there was a nonsignificant 9-dB better threshold at 4000 Hz for the elastic-band method. Experiment 2: Mean bone-conduction ASSR thresholds for the preterm infants were not significantly different for the temporal and mastoid placements. Mean ASSR thresholds for the forehead placement were significantly higher compared to the other two placements (12-18 dB higher on average). Mean ASSR amplitudes were significantly larger for the temporal and mastoid placements compared to the forehead placement. Experiment 3: There was no difference in mean ASSR thresholds, amplitudes or phase delays for the unoccluded versus occluded conditions. CONCLUSIONS: Trained assistants can apply an appropriate amount of force to the bone oscillator using either the elastic-band or hand-held method. Coupling method has no significant effect on estimation of bone-conduction thresholds; therefore, either may be used clinically provided assistants are appropriately trained. For preterm infants, there are no differences in ASSRs when the oscillator is positioned at the temporal or mastoid placement. However, thresholds are higher and amplitudes are smaller for the forehead placement, consequently, a forehead placement should be avoided for clinical testing. There does not appear to be a significant occlusion effect in young infants; therefore, it may be possible to do bone-conduction testing with ears unoccluded or occluded without applying a correction factor, although further research is needed to confirm this finding.

Acoustic Stimulation↗

Multiple auditory steady-state response thresholds to bone-conduction stimuli in young infants with normal hearing.

OBJECTIVE: Multiple auditory steady-state responses (ASSRs) probably will be incorporated into the diagnostic test battery for estimating hearing thresholds in young infants in the near future. Limiting this, however, is the fact that there are no published bone-conduction ASSR threshold data for infants with normal or impaired hearing. The objective of this study was to investigate bone-conduction ASSR thresholds in infants from a Neonatal Intensive Care Unit (NICU) and in young infants with normal hearing and to compare these with adult ASSR thresholds. DESIGN: ASSR thresholds to multiple bone-conduction stimuli (carrier frequencies: 500 to 4000 Hz; 77 to 101-Hz modulation rates; amplitude/frequency modulated; single-polarity stimulus) were obtained in two infant groups [N = 29 preterm (32 to 43 wk PCA), tested in NICU; N = 14 postterm (0 to 8 mo), tested in sound booth]. All infants had passed a hearing screening test. ASSR thresholds, amplitudes, and phase delays for preterm and postterm infants were compared with previously collected adult data. RESULTS: Mean (+/-1 SD) ASSR thresholds were 16 (11), 16 (10), 37 (10), and 33 (13) dB HL for the preterm infants and 14 (13), 2 (7), 26 (6), and 22 (8) dB HL for the postterm infants at 500, 1000, 2000, and 4000 Hz, respectively. Both infant groups had significantly better thresholds for 500 and 1000 Hz compared with 2000 and 4000 Hz, in contrast to adults who have similar thresholds across frequency (22, 26, 18, and 18 dB HL). When 500- and 1000-Hz thresholds were pooled, pre- and postterm infants had better low-frequency thresholds than adults. When 2000- and 4000-Hz thresholds were pooled, pre- and postterm infants had poorer thresholds than adults. ASSR amplitudes were significantly larger for low frequencies compared with high frequencies for both infant groups, in contrast to adults, who show little difference across frequency. ASSR phase delays were later for lower frequencies compared with higher frequencies for infants and adults, except for 500 Hz in the preterm group. ASSR phase delays were later for infants compared with adults across frequency. CONCLUSIONS: Infant bone-conduction ASSR thresholds are very different from those of adults. Overall, these results indicate that low-frequency bone-conduction thresholds worsen and high-frequency bone-conduction thresholds improve with maturation. Bone-conduction ASSR threshold differences between the postterm infants and adults probably are due to skull maturation. Differences between preterm and older infants may be explained both by skull changes and a masking effect of high ambient noise levels in the NICU (and possibly to other issues due to prematurity).

Acoustic Stimulation↗

Multiple auditory steady-state responses to bone-conduction stimuli in adults with normal hearing.

ASSR thresholds to bone-conduction stimuli were determined in 10 adults with normal hearing using mastoid placement of the bone oscillator. ASSRs to 0-50 dB HL bone-conduction stimuli and to 30-60 dB HL air-conduction stimuli were compared. The effect of alternating stimulus polarity on air- and bone-conduction ASSRs was also investigated. Stimuli were bone- and air-conduction amplitude-modulated tones (500-4000 Hz carrier frequencies, modulated at 77-101 Hz). ASSRs were recorded using the Rotman MASTER research system. Mean (1SD) bone-conduction ASSR thresholds were 22(11), 26(13), 18(8), and 18(11) dB HL for 500, 1000, 2000, and 4000 Hz, respectively. Except for a steeper slope at 500 Hz, ASSR intensity-amplitude functions for binaural bone- and air-conduction stimuli showed the same slopes; intensity-phase-delay functions were steeper at 1000 Hz for ASSRs to bone-conduction stimuli. ASSR amplitudes and phases did not differ for single- versus alternated-stimulus polarities for both bone- and air-conduction stimuli. The steeper amplitude slope for ASSRs to 500 Hz stimuli may reflect a nonauditory contribution to the ASSR.

Adult↗

Artifactual responses when recording auditory steady-state responses.

OBJECTIVE: The goal of this study was to investigate, in hearing-impaired participants who could not hear the stimuli, the possibility of artifactual auditory steady-state responses (ASSRs) when stimuli are presented at high intensities. DESIGN: ASSRs to single (60 dB HL) and multiple (20 to 50 dB HL; 500 to 4000 Hz) bone-conduction stimuli as well as single 114 to 120 dB HL air-conduction stimuli, were obtained using the Rotman MASTER system, using analog-to-digital (A/D) conversion rates of 500, 1000, and 1250 Hz. Responses (p < 0.05) were considered artifactual when their numbers exceeded that expected by chance. In some conditions, we also obtained ASSRs to "alternated" stimuli (stimuli inverted and ASSRs to the two polarities averaged). A total of 17 subjects were tested. RESULTS: Bone conduction results: 500 Hz A/D rate: Large-amplitude (43 to 1558 nV) artifactual ASSRs were seen at 40 and 50 dB HL for the 500 Hz carrier frequency. Smaller responses (28 to 53 nV) were also recorded at 20 dB HL for the 500 Hz carrier frequency. Artifactual ASSRs (17 to 62 nV) were seen at 40 dB HL and above for the 1000 Hz carrier frequency and at 50 dB HL for the 2000 Hz carrier frequency. Alternating the stimulus polarity decreased the amplitude and occurrence of these artifactual responses but did not eliminate responses for the 500 Hz carrier frequency at 40 dB HL and above. No artifactual responses were recorded for 4000 Hz stimuli for any condition. 1000 Hz A/D rate: Artifactual ASSRs (15 to 523 nV) were seen at 50 dB HL and above for the 500 Hz carrier frequency and 40 dB HL and above for the 1000 Hz carrier frequency. Artifactual responses were also obtained at 50 dB HL for a 2000 Hz carrier frequency but not at lower levels. Artifactual responses were not seen for the 4000 Hz carrier frequency. Alternating the stimulus polarity removed the responses for the 1000 and 2000 Hz carrier frequencies but did not change the results for the 500 Hz carrier frequency. 1250 Hz A/D rate: Artifactual ASSRs (16 to 220 nV) were seen at 50 dB HL and above for the 500 Hz carrier frequency and 60 dB HL and above for the 1000 Hz carrier frequency. Alternating the stimulus polarity removed the responses for the 1000 Hz carrier frequency but did not change the results for the 500 Hz carrier frequency. There were no artifactual responses at 2000 and 4000 Hz. Air conduction results: 500 Hz A/D rate: Artifactual ASSRs (49 to 153 nV) were seen for 114 to 120 dB HL stimuli for 500 and 1000 Hz carrier frequencies. Alternating the stimulus polarity removed these responses. There were no artifactual responses at 2000 and 4000 Hz. 1000 and 1250 Hz A/D rates: Artifactual ASSRs (19 to 55 nV) were seen for a 120 dB HL stimulus for a 1000 Hz carrier. Alternating the stimulus polarity removed these responses. CONCLUSIONS: High-intensity air- or bone-conduction stimuli can produce spurious ASSRs, especially for 500 and 1000 Hz carrier frequencies. High-amplitude stimulus artifact can result in energy that is aliased to exactly the modulation frequency. Choice of signal conditioning (electroencephalogram filter slope and low-pass cutoff) and processing (A/D rate) can avoid spurious responses due to aliasing. However, artifactual responses due to other causes may still occur for bone-conduction stimuli 50 dB HL and higher (and possibly for high-level air conduction). Because the phases of these spurious responses do not invert with inversion of stimulus, the possibility of nonauditory physiologic responses cannot be ruled out. The clinical implications of these results are that artifactual responses may occur for any patient for bone-conduction stimuli at levels greater than 40 dB HL and for high-intensity air-conduction stimuli used to assess patients with profound hearing loss.

Acoustic Stimulation↗

Normal brief-tone bone-conduction behavioral thresholds using the B-71 transducer: three occlusion conditions.

Behavioral thresholds were measured from 31 adults with normal hearing for 500, 1000, 2000, and 4000 Hz brief tones presented using a B-71 bone oscillator. Three occlusion conditions were assessed: ears unoccluded, one ear occluded, and both ears occluded. Mean threshold force levels were 67, 54, 49, and 41 dB re:1 microN peak-to-peak equivalent in the unoccluded condition for 500, 1000, 2000, and 4000 Hz, respectively (corrected for air-conduction pure-tone thresholds). A significant occlusion effect was observed for 500 and 1000 Hz stimuli. These thresholds may be used as the 0 dB nHL (normal-hearing level) for brief-tone bone-conduction stimuli for auditory brainstem response testing.

Acoustic Stimulation↗