Investigation of the metabolism of substance P at the blood-brain barrier using LC-MS/MS.

Substance P (SP) has been associated with pain and depression as well as neurodegenerative diseases. Many of these diverse actions of SP can potentially be attributed to SP metabolites generated at the blood-brain barrier (BBB). In this study, the metabolism of SP was investigated using an in vitro model of the BBB and LC-MS/MS. Substance P metabolism was found to be non-saturable in the concentration range of 100 nM to 10 microM, with approximately 70% of the peptide remaining intact after 5 h. The major metabolites of SP were identified by MS as 3-11 and 5-11. Two previously unreported metabolites, 5-11 and 6-11, were also found in our studies. Several additional minor SP metabolites, including 1-9 and 2-11, were also identified. A profile of the SP metabolites generated by the BBB over time was obtained. The results from the present study provide a better understanding of the role of the blood-brain barrier in the pharmacology of SP.

Animals↗

Evaluation of an osmotic pump for microdialysis sampling in an awake and untethered rat.

The feasibility of using an osmotic pump in place of a syringe pump for microdialysis sampling in rat brain was investigated. The use of an osmotic pump permits the rat to be free from the constraints of the standard tethered system. The in vitro flow rates of a microdialysis syringe pump (set at 10.80 microl/h) and the osmotic pump (pump specifications were 11.35 microl/h) with no probe attached were compared, yielding results of 10.87 microl/h+/-1.7% and 10.95 microl/h+/-8.0%, respectively. The average of four flow rate experiments in vivo yielded R.S.D.s less than 10% and an average flow rate of 11.1 microl/h. Following the flow rate studies, in vivo sampling of neurotransmitters was accomplished with the osmotic pump coupled to a microdialysis probe implanted in the brain. Finally, after determination of basal levels of 3,4-dihydroxyphenylacetic acid (DOPAC), homovanillic acid (HVA), and 5-hydroxyindole-3-acetic acid (5-HIAA) in the rats, the rats were dosed with benserazide followed by l-3,4-dihydroxyphenylalanine (l-DOPA). The results from the dosing study showed at least a 10-fold increase in compounds in the l-DOPA metabolic pathway (DOPAC and HVA) and a slight or no increase in 5-HIAA (serotonin metabolic pathway.) These results indicate that the osmotic pump is a viable alternative to the syringe pump for use in microdialysis sampling.

3,4-Dihydroxyphenylacetic Acid↗

A microchip electrophoresis device with on-line microdialysis sampling and on-chip sample derivatization by naphthalene 2,3-dicarboxaldehyde/2-mercaptoethanol for amino acid and peptide analysis.

The integration of rapid on-chip sample derivatization employing naphthalene 2,3-dicarboxaldehyde and 2-mercaptoethanol (NDA/2ME) with an easily assembled microdialysis/microchip electrophoresis device was carried out. The microchip device consisted of a glass layer with etched microfluidic channels that was sealed with a layer of poly(dimethylsiloxane) (PDMS) via plasma oxidation. This simple sealing procedure alleviated the need for glass thermal bonding and allowed the device to be re-sealed in the event of blockages within the channels. The device was used for analysis of a mixture of amino acids and peptides derivatized on-chip with NDA/2ME for laser-induced fluorescence (LIF) detection. A 0.6 mM NDA/1.2 mM 2ME mixture was simply added into the buffer reservoir for dynamic on-column derivatization of sample mixtures introduced at a flow rate of 1.0 microl/min. Using this scheme, sample injection plugs were derivatized and separated simultaneously. Injections of ca. 12 fmol of 5 mM amino acid and peptide samples were conducted using the system. Finally, a three-component mixture of Arg, Gly-Pro, and Asp was sampled from a vial using microdialysis, derivatized, separated and detected with the system. The ultimate goal of this effort is the creation of a micro-total analysis system for high-temporal resolution monitoring of primary amines in biological systems.

Amino Acids↗

Characteristics of substance P transport across the blood-brain barrier.

PURPOSE: Substance P (SP; NH3(+)-Arg(+)-Pro-Lys(+)-Pro-Gln-Gln-Phe-Phe-Gly-Leu-Met-NH2) belongs to a group of neurokinins that are widely distributed in the central nervous system and peripheral nervous system. The biological effects mediated by SP in the central nervous system include regulation of affective behavior, emesis, and nociception. Many of these actions are believed to be the result of the binding of SP to the neurokinin-1 (NK-1) receptor and subsequent transport across the blood-brain barrier (BBB). The objective of the study was to investigate the involvement of the NK-1 receptor in the permeation of SP across the BBB. METHODS: Transport of 3H SP (1-13 nM) was investigated using BBMEC monolayers grown on polycarbonate membranes mounted on a Side-bi-Side diffusion apparatus. 3H SP samples were analyzed by scintillation spectrometry. Liquid chromatography-tandem mass spectrometry was used to monitor the transport at higher concentrations (micromolar). RESULTS: SP transport across BBMEC monolayers was found to be saturable (Km = 8.57 +/- 1.59 nM, Vmax = 0.017 +/- 0.005 pmol min(-1) mg(-1) protein) in the concentration range of 0-13 nM. Significant (p < 0.05) decline in 3H SP permeation was observed in the presence of unlabeled SP and at 4 degrees C, indicating that the transport process is carrier-mediated. High-performance liquid chromatography analysis showed no significant metabolism of 3H SP in either the donor or receiver chambers. 3H SP transport was inhibited by 2-11 SP (p < 0.05) but not by any other fragments, indicating that both the C- and N-terminal regions are essential for molecular recognition by the receptor. Endocytic inhibitors (chloroquine, phenylarsine oxide, monensin, and brefeldin) did not inhibit SP transport, suggesting the involvement of a nonendocytic mechanism in SP permeation. Pro(9) SP, a high-affinity substrate for the NK-1 major subtype receptor, significantly (p < 0.05) inhibited the transport of SP. However, Sar(9)Met(O2)(11) SP, a high-affinity substrate for the NK-1 minor subtype receptor, septide, and neurokinin A, inhibitors of NK-1 and neurokinin-2 (NK-2) receptors, respectively, did not produce any inhibition of SP transport. Western blot analysis confirmed the presence of the NK-1 receptor in BBMEC monolayers. CONCLUSIONS: The above results provide functional and molecular evidence for the existence of a carrier-mediated mechanism in the transport of SP across the BBB. The effects of specific inhibitors and the results of Western blot analyses demonstrate the involvement of the NK-1 receptor in the transport of SP across the BBB.

Animals↗

Design and characterization of poly(dimethylsiloxane)-based valves for interfacing continuous-flow sampling to microchip electrophoresis.

This work describes the fabrication and evaluation of a poly(dimethyl)siloxane (PDMS)-based device that enables the discrete injection of a sample plug from a continuous-flow stream into a microchannel for subsequent analysis by electrophoresis. Devices were fabricated by aligning valving and flow channel layers followed by plasma sealing the combined layers onto a glass plate that contained fittings for the introduction of liquid sample and nitrogen gas. The design incorporates a reduced-volume pneumatic valve that actuates (on the order of hundreds of milliseconds) to allow analyte from a continuously flowing sampling channel to be injected into a separation channel for electrophoresis. The injector design was optimized to include a pushback channel to flush away stagnant sample associated with the injector dead volume. The effect of the valve actuation time, the pushback voltage, and the sampling stream flow rate on the performance of the device was characterized. Using the optimized design and an injection frequency of 0.64 Hz showed that the injection process is reproducible (RSD of 1.77%, n = 15). Concentration change experiments using fluorescein as the analyte showed that the device could achieve a lag time as small as 14 s. Finally, to demonstrate the potential uses of this device, the microchip was coupled to a microdialysis probe to monitor a concentration change and sample a fluorescein dye mixture.

Dimethylpolysiloxanes↗

Microchip capillary electrophoresis: application to peptide analysis.

The development of analytical methodologies to elucidate mechanisms of peptide transport and metabolism is important for the understanding of disease states and the design of effective drug therapies. Interest in the use of microchip capillary electrophoresis (CE) devices for peptide analysis stems from the ability to perform fast, highly efficient separations combined with small sample volume requirements. Many of the separation modes developed on conventional systems, including electrochromatography, isoelectric focusing, and electrophoretic bioaffinity assays, have been demonstrated on microchip devices. Steps that include sample preparation and labeling can also be integrated onto the microchip platform. This chapter will discuss considerations for peptide analysis using microchip CE and will focus on different approaches to sample preparation, separation, and detection.

Affinity Labels↗

Separation and detection of peroxynitrite and its metabolites by capillary electrophoresis with UV detection.

A method for the separation and direct detection of peroxynitrite (ONOO(-)) and two of its degradation products, nitrite (NO(2)(-)) and nitrate (NO(3)(-)), using capillary electrophoresis with ultraviolet detection is described. The separation parameters were optimized and included electrokinetic injection, a run buffer consisting of 25 mM K(2)HPO(4) 7.5 mM DTAB, pH 12, and a field strength of -323 V/cm. A diode array UV detector was employed in these studies as it allowed the determination of all three species simultaneously. Nitrate and nitrite provided the maximum response at 214 nm while peroxynitrite generated the best response at 302 nm. All three species could be detected at 214 nm, while simultaneous detection at 214 and 302 nm positively identified each peak.

Electrophoresis, Capillary↗

Rapid fabrication of poly(dimethylsiloxane)-based microchip capillary electrophoresis devices using CO2 laser ablation.

The use of CO(2) laser ablation for the patterning of capillary electrophoresis (CE) microchannels in poly(dimethylsiloxane)(PDMS) is described. Low-cost polymer devices were produced using a relatively inexpensive CO(2) laser system that facilitated rapid patterning and ablation of microchannels. Device designs were created using a commercially available software package. The effects of PDMS thickness, laser focusing, power, and speed on the resulting channel dimensions were investigated. Using optimized settings, the smallest channels that could be produced averaged 33 microm in depth (11.1% RSD, N= 6) and 110 microm in width (5.7% RSD, N= 6). The use of a PDMS substrate allowed reversible sealing of microchip components at room temperature without the need for cleanroom facilities. Using a layer of pre-cured polymer, devices were designed, ablated, and assembled within minutes. The final devices were used for microchip CE separation and detection of the fluorescently labeled neurotransmitters aspartate and glutamate.

Dimethylpolysiloxanes↗

On-line coupling of microdialysis sampling with microchip-based capillary electrophoresis.

Microdialysis sampling is a technique that has been used for in vivo and in vitro monitoring of compounds of pharmaceutical, biomedical, and environmental interest. The coupling of a commercially available microdialysis probe to a microchip-based capillary electrophoresis (CE) system is described. A continuously flowing dialysate stream from a microdialysis probe was introduced into the microchip, and discrete injections were achieved using a valveless gating approach. The effect of the applied voltage and microdialysis flow rate on device performance was investigated. It was found that the peak area varied linearly with the applied voltage. Higher voltages led to lower peak response but faster separations. Perfusion flow rates of 0.8 and 1.0 microL/min were found to provide optimal performance. The on-line microdialysis/microchip CE system was used to monitor the hydrolysis of fluorescein mono-beta-d-galactopyranoside (FMG) by beta-d-galactosidase. A decrease of the FMG substrate with an increase in the fluorescein product was observed. The temporal resolution of the device, which is dependent on the CE separation time, was 30 s. To the best of our knowledge, this is the first reported coupling of a microdialysis sampling probe to a microchip capillary electrophoresis device.

Electrophoresis, Microchip↗

Development of a microfabricated palladium decoupler/electrochemical detector for microchip capillary electrophoresis using a hybrid glass/poly(dimethylsiloxane) device.

The fabrication and evaluation of a palladium decoupler and working electrode for microchip capillary electrophoresis (CE) with electrochemical detection is described. The use of the Pd decoupler allows the working electrode to be placed directly in the separation channel and eliminates the band-broadening characteristic of the end-channel configuration. The method used for fabrication of the decoupler and working electrode was based on thin-layer deposition of titanium followed by palladium onto a glass substrate. When employed as the cathode in CE, palladium absorbs the hydrogen gas that is generated by the hydrolysis of water. The effect of the decoupler size on the ability to remove hydrogen was evaluated with regard to reproducibility and longevity. Using boric acid and TES buffer systems, 500 microm was determined to be the optimum decoupler size, with effective voltage isolation lasting for approximately 6 h at a constant field strength of 600 V/cm. The effect of distance between the decoupler and working electrode on noise and resolution for the separation of dopamine and epinephrine was also investigated. It was found that 250 microm was the optimum spacing between the decoupler and working electrode. At this spacing, laser-induced fluorescence detection at various points around the decoupler established that the band broadening due to pressure-induced flow that occurs after the decoupler did not significantly affect the separation efficiency of fluorescein. Limits of detection, sensitivity, and linearity for dopamine (500 nM, 3.5 pA/microM, r(2) = 0.9996) and epinephrine (2.1 microM, 2.6 pA/microM, r(2) = 0.9996) were obtained using the palladium decoupler in combination with a Pd working electrode.

Dimethylpolysiloxanes↗

Recent developments in electrochemical detection for microchip capillary electrophoresis.

Significant progress in the development of miniaturized microfluidic systems has occurred since their inception over a decade ago. This is primarily due to the numerous advantages of microchip analysis, including the ability to analyze minute samples, speed of analysis, reduced cost and waste, and portability. This review focuses on recent developments in integrating electrochemical (EC) detection with microchip capillary electrophoresis (CE). These detection modes include amperometry, conductimetry, and potentiometry. EC detection is ideal for use with microchip CE systems because it can be easily miniaturized with no diminution in analytical performance. Advances in microchip format, electrode material and design, decoupling of the detector from the separation field, and integration of sample preparation, separation, and detection on-chip are discussed. Microchip CEEC applications for enzyme/immunoassays, clinical and environmental assays, as well as the detection of neurotransmitters are also described.

Animals↗

Comparison of the performance characteristics of poly(dimethylsiloxane) and Pyrex microchip electrophoresis devices for peptide separations.

A comparative study of electrophoretic separations of fluorescently labeled peptides and amino acids on poly(dimethylsiloxane) (PDMS) and Pyrex microchips is presented. The separation parameters for each microchip substrate were compared, including electroosmotic flow, plate numbers, resolution, and limits of detection. The effect of buffer composition on the separation was also investigated. Acceptable separations were obtained for most peptides with both substrates; however, PDMS chips exhibited much lower separation efficiencies and longer analysis times.

Amino Acids↗

Amino acid and peptide analysis using derivatization with p-nitrophenol-2,5-dihydroxyphenylacetate bis-tetrahydropyranyl ether and capillary electrophoresis with electrochemical detection.

The amine derivatization reagent p-nitrophenol-2,5-dihydroxyphenylacetate bis-tetrahydropyranyl ether (NDTE) was used in conjunction with capillary electrophoresis (CE) and electrochemical detection (EC) for the pre-separation derivatization of primary amine analytes present in aqueous solution. Glycine, several dipeptides and angiotensin II were used as model analytes. A miniaturized EC detection cell was designed and fabricated, which featured a fractured-joint field decoupler with a fixed end-column carbon fiber electrode. When a series of glycine and angiotensin II calibration solutions were derivatized with NDTE followed by CE-EC determination, linear calibration plots resulted with pre-derivatization concentration limits of detection of 500 nM (106 attomoles on-column) and 6 microM (1.275 femtomoles on-column), respectively.

Amino Acids↗

Indirect measurement of nitric oxide production by monitoring nitrate and nitrite using microchip electrophoresis with electrochemical detection.

An indirect method for monitoring nitric oxide (NO) by determining nitrate and nitrite using microchip capillary electrophoresis (CE) with electrochemical (EC) detection has been developed. This method combines determination of nitrite by direct amperometric detection following a microchip-based CE separation and conversion of nitrate to nitrite by chemical reduction using Cu-coated Cd granules. The amount of nitrate is quantified by calculating the difference in the amount of nitrite in the sample before and after the reduction of nitrate. Optimization of the separation, injection, detection, and reduction reaction conditions, as well as studies involving integration of the reduction reaction onto the microchip, are described. It was found that nitrite can be separated and detected in approximately 45 s by microchip CEEC. The reduction reaction was successfully integrated on-chip and carried out in approximately 1 min following activation of the Cd granules. The usefulness of this device was demonstrated by monitoring the amount of nitrate and nitrite produced from 3-morpholinosydnonimine, a NO-releasing compound.

Electrochemistry↗

In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat.

A new electrode configuration for microchip capillary electrophoresis (CE) with electrochemical (EC) detection is described. This approach makes it possible to place the working electrode directly in the separation channel. The "in-channel" EC detection was accomplished without the use of a decoupler through the utilization of a specially designed, electrically isolated potentiostat. The effect of the working electrode position on the separation performance (in terms of plate height and peak skew) of poly(dimethylsiloxane)-based microchip CEEC devices was evaluated by comparing the more commonly used end-channel configuration with this new in-channel approach. Using catechol as the test analyte, it was found that in-channel EC detection decreased the total plate height by a factor of 4.6 and lowered the peak skew by a factor of 1.3. A similar trend was observed for the small, inorganic ion nitrite. Furthermore, a fluorescent and electrochemically active amino acid derivative was used to directly compare the separation performance of in-channel EC detection to that of a widely used laser-induced fluorescence (LIF) detection scheme. In this case, it was found that the plate height and peak skew for both detection schemes were essentially equal, and the separation performance of in-channel EC detection is comparable to LIF detection.

Catechols↗

Detection of homocysteine by conventional and microchip capillary electrophoresis/electrochemistry.

A method based on capillary electrophoresis (CE) with electrochemical (EC) detection for the determination of both total homocysteine (tHcy) and protein-bound homocysteine (pbHcy) in plasma is described. Both end-column and off-column amperometric detection were investigated. Off-column detection resulted in a more sensitive assay for the determination of homocysteine (Hcy). The detection limit for homocysteine was 500 nM using off-column EC detection and the response was linear over the range 1-100 microM. Therefore, this assay is appropriate for the quantification of Hcy over the physiological concentration ranges found in all disease states. Methodologies for the determination of tHcy and pbHcy in human plasma were investigated and optimized and the concentrations of both pbHcy and tHcy in plasma obtained from a healthy individual were determined to be 2.79+/-0.31 nuM (n = 4) and 3.37+/-0.15 microM (n = 3), respectively. The methodology was then transferred to a microchip CE-EC format and Hcy and reduced glutathione (GSH) were detected. Future work will focus on the development of ancillary methodologies to identify the other forms of Hcy in vivo.

Electrochemistry↗

Separation and detection of angiotensin peptides by Cu(II) complexation and capillary electrophoresis with UV and electrochemical detection.

The use of capillary electrophoresis (CE) with on-capillary Cu(II) complexation for the determination of angiotensin and its metabolites is described. The resulting copper-peptide complexes can be detected using either UV or electrochemical (EC) detection. Optimal reaction and separation conditions for the angiotensin peptides were first determined using CE with UV detection. With UV detection, the limit of detection (signal-to noise ratio S/N = 3) for native angiotensin II was 18 microM, while the limit of detection (LOD) obtained for the copper-angiotensin II complex is 2 microM. CE with EC detection was then evaluated, yielding significantly lower LODs--2 microM for native angiotensin II and 200 nM for the copper-angiotensin II complex. The addition of copper to the run buffer improved the separation and sensitivity for both CE-UV and CE-EC detection. The method was demonstrated by monitoring the conversion of angiotensin I to angiotensin II in plasma via angiotensin-converting enzyme (ACE) and subsequent inhibition of ACE by captopril.

Angiotensin I↗