PubMed Health⌕ Search

Biomedical subjects

Susan Sadeghi

Publications and source records attributed to Susan Sadeghi.

6 recordsLinked to original sources

Spectrophotometric determination of rifampicin through chelate formation and charge transfer complexation in pharmaceutical preparation and biological fluids.

Two simple and accurate spectrophotometric methods for determination of Rifampicin (RIF) are described. The first method is based on charge transfer (CT) complex formation of the drug with three pi-electron acceptors either 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), 7,7,7,8-Tetracyanoquinodimethane (TCNQ) or 2,3,5,6-Tetrachloro-1,4-benzoquinone (p-chloranil) in acetonitrile. The method is followed spectrophotometrically by measuring the maximum absorbance at 584 nm, 761 nm (680 nm) or 560 nm for DDQ, TCNQ and p-chloranil, respectively. Under the optimized experimental conditions, the calibration curves showed a linear relationship over the concentration ranges of 5-140 microg/ml, 2-45 microg/ml (5-120 microg/ml) and 15-200 microg/ml, respectively. The second method is based on the reaction of RIF with iron(III) forming a water insoluble violet complex which is extracted into chloroform. The method determines RIF in concentration range of 10-240 microg/ml at 540 nm. The proposed methods applied to determination of RIF in capsule, human serum and urine samples with good accuracy and precision. The results were compared statistically with the official method and showed no significant different between the methods compared in terms of accuracy and precision.

Calibration↗

Selective transport of copper(II) ions across a liquid membrane mediated by Piroxicam.

Piroxicam was found to be a highly selective carrier for uphill transport of Cu2+ ions through a chloroform liquid membrane. The transport occurs via a counterflow of protons from the receiving phase to the source phase. The effects of several parameters on the transport of Cu2+ ions, such as the carrier concentration, pH of the source phase, composition of the receiving phase, and duration are described. A high transport efficiency (98+/-2%) was provided by the carrier for Cu2+ ions in a receiving phase of 0.01 mol l(-1) sulfuric acid after 4 h. Different metal ion transport experiments showed that Cu2+ ions were selectively transported over other ions, such as Co2+, Ni2+, Cd2+, Pb2+, Zn2+, UO2(2+) and ZrO2(2+) . In the presence of fluoride ions (used as a suitable masking agent in the source phase), the interfering effects of UO2(2+) and ZrO2(2+) ions were eliminated. The applicability of the method was tested on a real sample, and the results obtained show that it is potentially useful for solvent extraction of copper.

Anti-Inflammatory Agents, Non-Steroidal↗

Molecularly imprinted solid-phase extraction for the screening of antihyperglycemic biguanides.

A new molecularly imprinted polymer (MIP) was specifically synthesized as a smart material for the recognition of metformin hydrochloride in solid-phase extraction. Particles of this MIP were packed into a stainless-steel tubing (50 mm x 0.8 mm i.d.) equipped with an exit frit. This micro-column was employed in the development of a molecularly imprinted solid-phase extraction (MISPE) method for metformin determination. The MISPE instrumentation consisted of a micrometer pump, an injector valve equipped with a 20-microl sample loop, a UV detector, and an integrator. With CH3CN as the mobile phase flowing at 0.5 ml/min, 95 +/- 2% binding could be achieved for 1200 ng of metformin from one injection of a phosphate-buffered sample solution (pH 2.5). Methanol + 3% trifluoroacetic acid was good for quantitative pulsed elution (PE) of the bound metformin. The MISPE-PE method, with UV detection at 240 nm, afforded a detection limit of 16 ng (or 0.8 microg/ml) for metformin. However, the micro-column interacted indiscriminately with phenformin with a 49 +/- 2% binding. A systematic investigation of binding selectivity was conducted with respect to sample composition (including the solvent, matrix, pH, buffer and surfactant effects). An intermediate step of differential pulsed elution used acetonitrile with 5% picric acid to remove phenformin and other structural analogues. A final pulsed elution of metformin for direct UV detection was achieved using 3% trifluoroacetic acid in methanol.

Biguanides↗

Solid-phase extraction-spectrophotometric determination of uranium(VI) in natural waters.

A method for the extraction and determination of uranyl ion in natural waters using octadecyl bonded silica membrane disks modified with piroxicam and spectrophotometry with arsenazo(III) is proposed. The perconcentration step was studied with regard to experimental parameters such as amount of extractant, type and amount of eluent, pH, flow rates and tolerance limit of diverse ions on the recovery of uranyl ion. The limit of detection of the proposed method is 0.4 micro g L(-1) of uranyl. The method was applied to the recovery of uranyl from different water samples.

Journal Article↗

Triiodide PVC membrane electrodes based on charge-transfer complexes.

Three new electrodes were prepared by incorporating two different charge-transfer complexes and amino crown ether into plasticized PVC membranes. The electrodes showed Nernstian response to triiodide ion over the activity range from 1.0 x 10(-5) to 1.0 x 10(-1) mol x L(-1) with detection limits at approximately 1.0 x 10(-6) mol x L(-1). The resulting electrodes have fast response times (20-30 s) and good stabilities (4 months) and can be used over a wide pH range of 2.5-9.0. The proposed electrodes exhibit anti-Hofmeister behavior with excellent selectivity toward triiodide ion against a wide range of common interferences. Comparative study suggests that amino (aza) crown ether alone or in the form of a charge-transfer complex with iodine, as an ionophore in a PVC liquid membrane, is sensitive to triiodide ion. The electrodes were used as indicator electrodes in potentiometric titration of triiodide ion against thiosulfate ion.

Electrochemistry↗

Copper (II) ion selective liquid membrane electrode based on new Schiff base carrier.

Cu2+ selective PVC membrane electrode based on new Schiff base 2, 2'-[1,9 nonanediyl bis (nitriloethylidyne)]-bis-(1-naphthol) as a selective carrier was constructed. The electrode exhibited a linear potential response within the activity range of 1.0 x 10(-6) - 5.0 x 10(-3) moll(-1) with a Nernstian slope of 29 +/- 1 mV decade(-1) of Cu2+ activity and a limit of detection 8.0 x 10(-7) mol l(-1). The response time of the electrode was fast, 10 s, and stable potentials were obtained within the pH range of 3.5- 6.5. The potentiometric selectivity coefficients were evaluated using two solution method and revealed no important interferences except for Ag+ ion. The proposed electrode was applied as an indicator electrode to potentiometric titration of Cu2+ ions and determination of Cu2+ content in real samples such as black tea leaves and multivitamin capsule.

Biosensing Techniques↗