PubMed Health⌕ Search

Biomedical subjects

Susan Waltzman

Publications and source records attributed to Susan Waltzman.

2 recordsLinked to original sources

Comparison of continuous interleaved sampling and simultaneous analog stimulation speech processing strategies in newly implanted adults with a Clarion 1.2 cochlear implant.

OBJECTIVE: This study consisted of a within-subjects comparison of speech recognition and patient preference when subjects used two different cochlear implant speech processing strategies with a Clarion 1.2 (enhanced bipolar) device: Simultaneous Analog Stimulation (SAS), and Continuous Interleaved Sampling (CIS). These two strategies used two different electrode configurations: the SAS strategy used bipolar stimulation, whereas the CIS strategy used monopolar stimulation. STUDY DESIGN: This was a multicenter study that used a within-subjects balanced crossover design. Experience with the two strategies was replicated in each subject using an ABAB design. Order of strategy use was balanced across all subjects. SETTING: The study was carried out at several cochlear implant centers affiliated with tertiary medical centers. PATIENTS: Subjects consisted of 25 postlingually deafened adults who received a Clarion cochlear implant. INTERVENTIONS: Total involvement by each subject was 14 weeks. Speech perception testing and sound quality assessments were performed after use with each strategy. MAIN OUTCOME MEASURES: Primary outcome measures include speech perception data and patient responses to questionnaires regarding speech and sound quality. RESULTS: Analyses revealed that performance did not differ significantly by the strategy encountered first as relative to the strategy encountered second and that the order in which a strategy was used did not appear to affect subjects' eventual preference for a particular strategy. Although speech recognition scores tended to be higher for CIS for most of the test measures at most of the test intervals, the analysis of variance to evaluate differences in strategy did not reveal a significant effect of strategy. Further analysis of scores obtained at the replication interval, however, revealed that scores obtained with CIS were significantly higher than scores obtained with SAS on the Hearing in Noise Test sentences in quiet and noise. In addition, significantly more patients indicated a final preference for the CIS strategy than for the SAS strategy. Importantly, both the analysis evaluating order and the analysis evaluating strategy revealed significant effects of evaluation period, indicating that time/experience with the implant had a significant effect on scores for each strategy, regardless of the order in which it was used (first or second). CONCLUSIONS: This study demonstrates that important learning occurs during the first several weeks of cochlear implant use, making it difficult to adequately compare performance with different speech processing strategies. However, the finding that patients often prefer the strategy they understand speech the best with supports the clinical practice of letting adult patients select their preferred strategy without formally evaluating speech perception with each available strategy.

Aged↗

Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance.

OBJECTIVE: The study investigated the hypothesis that threshold and comfortable levels recorded from cochlear implant patients would reduce, and dynamic range increase, as distance of the electrode from the modiolar wall (radial distance) decreases. Two groups of cochlear implant patients participated; one group using the Nucleus' 24 Contour electrode array, and one group using the Nucleus standard straight (banded) array. The Nucleus 24 Contour array has been shown in temporal bone studies to lie closer to the modiolus than the banded array. The relationship of electrode impedance and radial distance is also investigated. DESIGN: The study, conducted at three centers, evaluated 21 patients using the Contour array, and 36 patients using the banded array. For each patient, threshold, comfortable levels and dynamic range were measured at four time points. Common ground electrode impedance was recorded clinically from each patient, at time intervals up to 12 wk. An estimate of the radial distance of the electrode from the modiolus was made by analysis of Cochlear view x-rays. RESULTS: Threshold and comfortable levels were significantly lower for the Nucleus 24 Contour array than for the banded array. However, dynamic range measurements did not show the predicted increase. In a majority of subjects, a significant correlation was found between the estimated radial distance of the electrode from the modiolus and the measured threshold and comfortable levels. This trend was not observed for dynamic range. The analysis indicates that other factors than radial distance are involved in the resultant psychophysical levels. Clinical impedance measures (common ground) were found to be significantly higher for the Contour array. However, the electrodes on the Contour array are half-rings, which are approximately only half the geometric size of the full rings as electrodes of the standard array. When the geometric electrode area in the two array designs are normalized, the trends in the electrode impedance behavior are similar. CONCLUSIONS: The results support the hypothesis that the relationship between the radial distance of the electrode and the psychophysical measures are influenced by patterns of fibrous tissue growth and individual patient differences, such as etiology and neural survival. Impedance measures for the Nucleus 24 Contour electrode array were higher than the banded electrode array, but this is primarily due to the reduction in electrode surface area. The different outcomes in impedance over time suggest differences in the relative contributions of the components of impedance with the two arrays.

Acoustic Impedance Tests↗