Susana Marcos

Publications and source records attributed to Susana Marcos.

At least 19 recordsLinked to original sources

Crystalline lens radii of curvature from Purkinje and Scheimpflug imaging.

We present a comparison between measurements of the radius of the anterior and posterior lens surface, which was performed using corrected Scheimpflug imaging and Purkinje imaging in the same group of participants (46 for the anterior lens, and 34 for the posterior lens). Comparisons were also made as a function of accommodation (0 to 7 D) in a subset of 11 eyes. Data were captured and processed using laboratory prototypes and custom processing algorithms [for optical and geometrical distortion correction in the Scheimpflug system and using either equivalent mirror (EM) or merit function (MF) methods for Purkinje]. We found statistically significant differences in 4 of 46 eyes for the anterior lens radius, and 10 of 34 eyes for the posterior radius (using the MF and individual biometric data to process the Purkinje images). For the anterior lens, the agreement increases using individual biometry as opposed to biometric data from a model eye. For the posterior lens, the agreement increases using the MF as opposed to the EM method. For the changes during accommodation, no significant difference between the two techniques was found. In conclusion, the results of the cross-validation using the Scheimpflug and Purkinje imaging technique show that both techniques provide comparable lens radii and similar changes with accommodation. Purkinje tends to overestimate posterior lens radius, whereas pupil size limits the acquisition of posterior lens data with the Scheimpflug camera. Computer simulations using the Scheimpflug data as input show that the consistent slight overestimation of the posterior lens radius using Purkinje imaging can be partly attributed to the asphericity of the lens surface.

Accommodation, Ocular↗

Optical aberrations in the mouse eye.

PURPOSE: The mouse eye is a widely used model for retinal disease and has potential to become a model for myopia. Studies of retinal disease will benefit from imaging the fundus in vivo. Experimental models of myopia often rely on manipulation of the visual experience. In both cases, knowledge of the optical quality of the eye, and in particular, the retinal image quality degradation imposed by the ocular aberrations is essential. In this study, we measured the ocular aberrations in the wild type mouse. METHODS: Twelve eyes from six four-week old black C57BL/6 wild type mice were studied. Measurements were done on awake animals, one being also measured under anesthesia for comparative purposes. Ocular aberrations were measured using a custom-built Hartmann-Shack system (using 680-nm illumination). Wave aberrations are reported up to fourth order Zernike polynomials. Spherical equivalent and astigmatism were obtained from the 2nd order Zernike terms. Modulation Transfer Functions (MTF) were estimated for the best focus, and through-focus, to estimate depth-of-focus. All reported data were for 1.5-mm pupils. RESULTS: Hartmann-Shack refractions were consistently hyperopic (10.12+/-1.41 D, mean and standard deviation) and astigmatism was present in many of the eyes (3.64+/-3.70 D, on average). Spherical aberration was positive in all eyes (0.15+/-0.07 microm) and coma terms RMS were significantly high compared to other Zernike terms (0.10+/-0.03 microm). MTFs estimated from wave aberrations show a modulation of 0.4 at 2c/deg, for best focus (and 0.15 without cancelling the measured defocus). For that spatial frequency, depth-of-focus estimated from through-focus modulation data using the Rayleigh criterion was 6D. Aberrations in the eye of one anesthetized mouse were higher than in the same eye of the awake animal. CONCLUSIONS: Hyperopic refractions in the mouse eye are consistent with previous retinoscopic data. The optics of the mouse eye is far from being diffraction-limited at 1.5-mm pupil, with significant amounts of spherical aberration and coma. However, estimates of MTFs from wave aberrations are higher than previously reported using a double-pass technique, resulting in smaller depth-of-field predictions. Despite the large degradation imposed by the aberrations these are lower than the amount of aberrations typically corrected by available correction techniques (i.e., adaptive optics). On the other hand, aberrations do not seem to be the limiting factor in the mouse spatial resolution. While the mouse optics are much more degraded than in other experimental models of myopia, its tolerance to large amounts of defocus does not seem to be determined entirely by the ocular aberrations.

Animals↗

Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements.

We present a Purkinje imaging system for phakometry and measurement of tilt and decentration of crystalline and intraocular lenses (IOLs). Crystalline lens radii of curvature were estimated by using both a merit function and the equivalent mirror approaches. Tilts and decentrations were estimated by using Phillips's linear analysis. We present a complete validation of the technique through exhaustive computer simulations and control experiments, and measurements in 17 normal eyes (mean age 26.67 +/- 2.31) and nine postcataract surgery eyes (mean age 74 +/- 2.3). Crystalline lens radii ranged from 12.7 to 8.81 mm and from -5.64 to -7.09 mm for anterior and posterior surfaces, respectively. Crystalline lens tilt ranged from 2.8 to -2.87 deg horizontally and from 2.58 to -1 deg vertically. Crystalline lens decentration ranged from 0.09 to 0.45 mm horizontally and from 0.09 to -0.22 mm vertically. IOL tilt ranged from 3.6 to -1.51 deg horizontally and from 5.97 to -1.85 deg vertically. IOL decentration ranged from 0.53 to -0.31 mm horizontally and from 0.13 to -0.96 mm vertically.

Corneal Topography↗

Myopic versus hyperopic eyes: axial length, corneal shape and optical aberrations.

This study investigated differences in geometrical properties and optical aberrations between a group of hyperopes and myopes (age-matched 30.3+/-5.2 and 30.5+/-3.8 years old, respectively, and with similar absolute refractive error 3.0+/-2.0 and -3.3+/-2.0, respectively). Axial length (AL) was measured by means of optical biometry, and corneal apical radius of curvature (CR) and asphericity (Q) were measured by fitting corneal topography data to biconic surfaces. Corneal aberrations were estimated from corneal topography by means of virtual ray tracing, and total aberrations were measured using a laser ray tracing technique. Internal aberrations were estimated by subtracting corneal from total aberrations. AL was significantly higher in myopes than in hyperopes and AL/CR was highly correlated with spherical equivalent. Hyperopic eyes tended to have higher (less negative) Q and higher total and corneal spherical aberration than myopic eyes. RMS for third-order aberrations was also significantly higher for the hyperopic eyes. Internal aberrations were not significantly different between the myopic and hyperopic groups, although internal spherical aberration showed a significant age-related shift toward less negative values in the hyperopic group. For these age and refraction ranges, our cross-sectional results do not support evidence of relationships between emmetropization and ocular aberrations. Our results may be indicative of presbyopic changes occurring earlier in hyperopes than in myopes.

Adult↗

Comparison of real and computer-simulated outcomes of LASIK refractive surgery.

Computer simulations of alternative LASIK ablation patterns were performed for corneal elevation maps of 13 real myopic corneas (range of myopia, -2.0 to -11.5 D). The computationally simulated ablation patterns were designed with biconic surfaces (standard Munnerlyn pattern, parabolic pattern, and biconic pattern) or with aberrometry measurements (customized pattern). Simulated results were compared with real postoperative outcomes. Standard LASIK refractive surgery for myopia increased corneal asphericity and spherical aberration. Computations with the theoretical Munnerlyn ablation pattern did not increase the corneal asphericity and spherical aberration. The theoretical parabolic pattern induced a slight increase of asphericity and spherical aberration, explaining only 40% of the clinically found increase. The theoretical biconic pattern controlled corneal spherical aberration. Computations showed that the theoretical customized pattern can correct high-order asymmetric aberrations. Simulations of changes in efficiency due to reflection and nonnormal incidence of the laser light showed a further increase in corneal asphericity. Consideration of these effects with a parabolic pattern accounts for 70% of the clinical increase in asphericity.

Computer Simulation↗

The influence of the Stiles-Crawford peak location on visual performance.

We investigated the influence of the Stiles-Crawford peak location on visual acuity, contrast sensitivity and phase transfer with 6 mm diameter pupils in two subjects. Apodising filters were used to move the peak. One subject (SM) had her natural peak 0.9 mm below pupil centre, and visual performance was measured for both this peak position and when the peak was moved to the same distance above pupil centre. The other subject (DAA) had a more centred peak and visual performance was measured for this peak position and when the peak was moved both 2.3 mm temporally and 2.6 mm nasally. Measurements of contrast sensitivity and phase transfer were compared with predictions based on aberration measurements. The peak position had definite influence on performance, but this was mainly noticeable when subjects were defocused e.g. SM's visual acuity was reduced by 0.13 log units under the peak-shifted condition at -2D (hypermetropic) defocus.

Adult↗

Aberrations of the human eye in visible and near infrared illumination.

PURPOSE: In most current aberrometers, near infrared light is used to measure ocular aberrations, whereas in some applications, optical aberration data in the visible range are required. We compared optical aberration measurements using infrared (787 nm) and visible light (543 nm) in a heterogeneous group of subjects to assess whether aberrations are similar in both wavelengths and to estimate experimentally the ocular chromatic focus shift. METHODS: Ocular aberrations were measured in near infrared and visible light using two different laboratory-developed systems: laser ray tracing (LRT) and Shack-Hartmann. Measurements were conducted on 36 eyes (25 and 11 eyes, respectively), within a wide range of ages (20 to 71 years), refractive errors (-6.00 to +16.50), and optical quality (root mean square wavefront error, excluding defocus, from 0.40 to 9.89 microm). In both systems, wave aberrations were computed from the ray aberrations by modal fitting to a Zernike polynomial base (up to seventh order in laser ray tracing and sixth order in Shack-Hartmann). We compared the Zernike coefficients and the root mean square wavefront error corresponding to different terms between infrared and green illumination. RESULTS: A Student's t-test performed on the Zernike coefficients indicates that defocus was significantly different in all of the subjects but one. Average focus shift found between 787 nm and 543 nm was 0.72 D. A very small percentage of the remaining coefficients was found to be significantly different: 4.7% of the 825 coefficients (25 eyes with 33 terms) for laser ray tracing and 18.2% of the 275 coefficients (11 eyes with 25 terms) for Shack-Hartmann. Astigmatism was statistically different in 8.3% of the eyes, root mean square wavefront error for third-order aberrations in 16.6%, and spherical aberration (Z4(0)) in 11.1%. CONCLUSIONS: Aerial images captured using infrared and green light showed noticeable differences. Apart from defocus, this did not affect centroid computations because within the variability of the techniques, estimates of aberrations with infrared were equivalent to those measured with green. In normal eyes, the Longitudinal Chromatic Aberration of the Indiana Chromatic Eye Model can predict the defocus term changes measured experimentally, although the intersubject variability could not be neglected. The largest deviations from the prediction were found on an aphakic eye and on the oldest subject.

Adult↗

Double-pass measurement of retinal image quality in the chicken eye.

PURPOSE: The chicken, Gallus gallus domesticus, is used as an animal model to study the development of refractive error. Although vision is important in determining the eye's refractive state, relatively little is known about the retinal image quality of the chicken eye. An objective double-pass technique was used to measure the optical quality of the eyes of White Leghorn chickens. METHODS: Measurements were made on 21 eyes of six untreated birds and eight experimental birds that were members of a study of refractive development. Ages ranged from 3 to 6 weeks, and refractions ranged from -1.29 to +0.58 D in the untreated eyes and -4.58 to +10.17 D in the experimental eyes. The measurements were made under general anesthesia combined with either cycloplegia or ciliary nerve section. Proper optical alignment of the eye was achieved with the aid of a TV monitor, CCD camera, and an infrared source. A 543-nm laser point source was focused on the retina, and the double-pass aerial image was collected by a high-resolution CCD camera. Refractive errors were corrected with trial lenses, using a bracketing method to optimize the retinal images. Both the full width at half-maximum of the double-pass aerial image and the single-pass modulation transfer function were used as objective estimates of the optical quality. RESULTS: The mean full width at half-maximum value in eyes of the untreated birds was 1.60 min arc for a 4.50-mm mean pupil diameter. Optical quality tended to be worse in the experimental myopic eyes. CONCLUSIONS: The optical quality of the chicken eye measured under monochromatic conditions meets or may even exceed the neural limits of spatial acuity based on anatomical estimates of ganglion cell spacing. The data also suggest that optical quality is worse in myopic eyes, which is consistent with studies of human eyes.

Animals↗

On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry.

PURPOSE: Our aim was to obtain a complete description of the interactions of rigid gas permeable (RGP) contact lenses with the optics of normal eyes. METHODS: We measured total and anterior-surface aberrations in four subjects, who were all long-term RGP contact lens wearers. The anterior-surface wave aberration was obtained from videokeratographic elevation maps, and ocular wave aberration was measured with a laser ray-tracing technique. Measurements were performed with and without their own spherical contact lenses. RESULTS: With this methodology, we evaluated the optical performance with RGP lenses compared with the natural optics. We estimated the contribution of the anterior surface of the contact lens, the internal ocular optics, flexure, and the tear lens aberrations to the optical performance of eyes wearing RGP contact lenses. We found that in three of four subjects, the contact lens significantly improved the natural optics of the eye. For the subject with higher dominance of corneal aberrations, root mean square (second-order and higher) decreased from 1.36 microm to 0.46 microm. Third- and higher-order aberrations decreased from 0.77 microm to 0.39 microm. The internal optics and lens flexure imposed limits on aberration compensation. Spherical RGP contact lenses did not produce spherical aberration potentially due to a compensatory role of the tear lens. CONCLUSIONS: Aberration measurements are useful to understand the fitting of contact lenses and the interaction with tear, cornea, and internal optics of the eye. Aberrometry can help to choose the best standard RGP lens parameters to improve the optics of individual eyes.

Adolescent↗

Optical aberrations of intraocular lenses measured in vivo and in vitro.

Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not significantly different from aberrations in eyes before cataract surgery or from previously reported aberrations in healthy eyes of the same age. However, aberrations in pseudophakic eyes are significantly higher than in young eyes. We found a slight increase of corneal aberrations after surgery. The aberrations of the IOL and the lack of balance of the corneal spherical aberrations by the spherical aberrations of the intraocular lens also degraded the optical quality in pseudophakic eyes. We also measured the aberrations of the IOL in vitro, using an eye cell model, and simulated the aberrations of the IOL on the basis of the IOL's physical parameters. We found a good agreement among in vivo, in vitro, and simulated measures of spherical aberration: Unlike the spherical aberration of the young crystalline lens, which tends to be negative, the spherical aberration of the IOL is positive and increases with lens power. Computer simulations and in vitro measurements show that tilts and decentrations might be contributors to the increased third-order aberrations in vivo in comparison with in vitro measurements.

Aged↗

Imperfect optics may be the eye's defence against chromatic blur.

The optics of the eye cause different wavelengths of light to be differentially focused at the retina. This phenomenon is due to longitudinal chromatic aberration, a wavelength-dependent change in refractive power. Retinal image quality may consequently vary for the different classes of cone photoreceptors, cells tuned to absorb bands of different wavelengths. For instance, it has been assumed that when the eye is focused for mid-spectral wavelengths near the peak sensitivities of long- (L) and middle- (M) wavelength-sensitive cones, short-wavelength (bluish) light is so blurred that it cannot contribute to and may even impair spatial vision. These optical effects have been proposed to explain the function of the macular pigment, which selectively absorbs short-wavelength light, and the sparsity of short-wavelength-sensitive (S) cones. However, such explanations have ignored the effect of monochromatic wave aberrations present in real eyes. Here we show that, when these effects are taken into account, short wavelengths are not as blurred as previously thought, that the potential image quality for S cones is comparable to that for L and M cones, and that macular pigment has no significant function in improving the retinal image.

Adult↗

Corneal and total optical aberrations in a unilateral aphakic patient.

PURPOSE: To measure corneal and total optical aberrations in the normal and treated eye of a unilateral aphakic patient to (1) cross-validate techniques in an eye in which corneal and total aberrations should be almost identical (aphakic eye) and (2) compare the interactions of corneal and internal aberrations in the normal eye with those in the aphakic eye. SETTING: Instituto de Optica, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS: Aberrations in both eyes of a unilateral aphakic patient were measured using laser ray tracing. Corneal aberrations were obtained from corneal elevation data measured with a corneal videokeratoscope (Humphrey Instruments) using custom software that performs virtual ray tracing on the measured front corneal surface. RESULTS: There was a 98.4% correspondence between the total and corneal aberration pattern in the aphakic eye (6.5 mm pupil). In the normal eye, the total spherical aberration was much lower than the corneal spherical aberration; this did not occur in the aphakic eye. CONCLUSIONS: The posterior corneal surface contributed slightly to the aberrations in the normal cornea (2% at most). The crystalline lens appears to play a compensatory role in the total spherical aberration in normal eyes.

Adult↗

Ocular aberrations with ray tracing and Shack-Hartmann wave-front sensors: does polarization play a role?

Ocular aberrations were measured in 71 eyes by using two reflectometric aberrometers, employing laser ray tracing (LRT) (60 eyes) and a Shack-Hartmann wave-front sensor (S-H) (11 eyes). In both techniques a point source is imaged on the retina (through different pupil positions in the LRT or a single position in the S-H). The aberrations are estimated by measuring the deviations of the retinal spot from the reference as the pupil is sampled (in LRT) or the deviations of a wave front as it emerges from the eye by means of a lenslet array (in the S-H). In this paper we studied the effect of different polarization configurations in the aberration measurements, including linearly polarized light and circularly polarized light in the illuminating channel and sampling light in the crossed or parallel orientations. In addition, completely depolarized light in the imaging channel was obtained from retinal lipofuscin autofluorescence. The intensity distribution of the retinal spots as a function of entry (for LRT) or exit pupil (for S-H) depends on the polarization configuration. These intensity patterns show bright corners and a dark area at the pupil center for crossed polarization, an approximately Gaussian distribution for parallel polarization and a homogeneous distribution for the autofluorescence case. However, the measured aberrations are independent of the polarization states. These results indicate that the differences in retardation across the pupil imposed by corneal birefringence do not produce significant phase delays compared with those produced by aberrations, at least within the accuracy of these techniques. In addition, differences in the recorded aerial images due to changes in polarization do not affect the aberration measurements in these reflectometric aberrometers.

Adult↗

Validation of the estimation of corneal aberrations from videokeratography in keratoconus.

PURPOSE: To validate the estimation of corneal aberrations from videokeratography against a laser ray tracing technique that measured total eye aberrations, in eyes without keratoconus (ie, cornea-dominated wave aberrations). METHODS: We measured total and corneal wave aberrations of three eyes diagnosed with keratoconus by slit-lamp microscopy and corneal topography: two eyes from one patient with early keratoconus and one eye with more advanced keratoconus. Total aberrations were measured with laser ray tracing. Corneal aberrations were obtained from corneal elevation data measured with a corneal videokeratoscope using custom software that performs virtual ray tracing on the measured front corneal surface. RESULTS: The keratoconus eyes showed a dramatic increase in aberrations (both corneal and total) particularly coma-like terms, which were 3.74 times higher on average than normal. Anterior corneal surface aberrations and total aberrations Were similar in keratoconus. This similarity was greater for the early keratoconus patient, suggesting a possible implication of the posterior corneal surface in advanced keratoconus. CONCLUSIONS: The similarity found between corneal and total aberration patterns in keratoconus provided a cross-validation of both types of measurements (corneal topography and aberrometry). Both techniques were useful in diagnosing and quantifying optical degradation imposed by keratoconus.

Adult↗

Are changes in ocular aberrations with age a significant problem for refractive surgery?

We discuss current knowledge about the change of aberrations with aging, cataract surgery, and laser in situ keratomileusis (LASIK) for myopia. Based on this evidence, we speculate about the long-term expectations for postoperative LASIK eyes in terms of aberrations. Standard myopic LASIK surgery produces a significant increase in aberrations, particularly corneal spherical aberration, which changes to positive values. Aberrations increase with age, and in particular, the spherical aberration of the crystalline lens shifts toward positive values. Therefore, no compensatory effect is expected to occur with age after standard myopic LASIK, but rather the unusually high amount of aberrations in postoperative LASIK patients is expected to worsen with age. The amount of aberrations in patients after cataract surgery with implantation of standard intraocular lenses (IOLs) is higher than in normal young subjects. If an ideal customized ablation (not inducing aberrations and reducing naturally existing aberrations) is ever possible, the perfect correction will not last (due to the change of aberrations with age), and aberrations of the crystalline lens corrected on the cornea are likely to reappear after conventional cataract surgery. Potential benefits of customized IOLs for cataract surgery and improved optics in older patients are discussed.

Aging↗