PubMed Health⌕ Search

Biomedical subjects

Susumu Honda

Publications and source records attributed to Susumu Honda.

At least 19 recordsLinked to original sources

Purification of boron nitride nanotubes through polymer wrapping.

An effective method was proposed to remove obstinate boron nitride phase impurities in boron nitride nanotubes (BNNTs). The method is based on strong interactions between BNNTs and a conjugated polymer wrapping them and significant weight and size difference between BNNTs and impurities. The as-grown samples and purified samples were compared through detailed characterization, using scanning electron microscopy, transmission electron microscopy, and Raman and Fourier transformed infrared spectroscopy. The results reveal that impurities are effectively removed and resultant BNNTs possess perfect crystallization.

Journal Article↗

A sulfonated capillary that gives reproducible migration times for capillary zone electrophoresis and micellar electrokinetic chromatography.

To obtain reproducible migration times and rapid analyses of analytes, sulfonate groups were chemically introduced to the inner wall of untreated fused-silica capillary with 2-(4-chlorosulfonylphenyl)ethyltrichlorosilane. The sulfonated capillary showed relatively constant electroosmotic mobility which was greater than that obtained by an untreated fused-silica capillary over the pH range studied (pH 2-9). In both CZE and MEKC, the RSDs of the migration times of analytes with the sulfonated capillary were less than 0.2% which were significantly lower than those obtained with an untreated fused-silica capillary (0.5-3.5%). When BGE were set at pH 7.0 for CZE and MEKC, the analysis times with the sulfonated capillary were about half those obtained with an untreated fused-silica capillary. These results indicate that the sulfonated capillary can provide highly reproducible and rapid analyses in CE.

Acids, Carbocyclic↗

Search for serum protein-binding disaccharides and disaccharide-binding serum proteins by affinity capillary electrophoresis.

The potential use of affinity capillary electrophoresis in a microscale search for mutually interacting substances in biological fluid is demonstrated. Some disaccharides, especially gentiobiose (Gen), derivatized with 1-phenyl-3-methyl-5-pyrazolone, caused peak retardation when electrophoresed in a neutral running buffer, containing human serum. Gen, the most significantly retarded disaccharide, was converted to its negatively charged bis-mercaptoethanesulfonate derivative (MerESGen), and a serum sample was analyzed in a neutral buffer containing the derivatized disaccharide. Two peaks, belonging to the beta-globulin fraction, were found to be remarkably retarded in the buffer containing MerES-Gen in a concentration-dependent way. These findings prove an interaction between disaccharides and serum proteins.

Beta-Globulins↗

Analysis of carbohydrates as 1-phenyl-3-methyl-5-pyrazolone derivatives by capillary/microchip electrophoresis and capillary electrochromatography.

The 1-phenyl-3-methyl-5-pyrazolone (PMP) method has many advantages over hitherto reported methods based on reductive amination and hydrazone formation. This short review summarizes the various aspects of the PMP method, including the principle of derivatization, the simplicity of derivatization procedure, the high sensitivities to UV monitoring and ESI-MS, and the diversity of separation modes in capillary electrophoresis, and presents a number of application data for carbohydrate analysis in biological samples by this method. It also describes successful automation of carbohydrate analysis by in-capillary derivatization with PMP and miniaturization to microchip electrophoresis with whole channel UV detection allowing rapid (within 1 min) analysis of small amounts of PMP derivatives of carbohydrates. Furthermore, it discusses the possibility of capillary electrochromatography in carbohydrate analysis as PMP derivatives, and proposes an in-capillary modification strategy for improving column efficiency and elution time reproducibility.

Antipyrine↗

Capillary electrophoretic separation of drug enantiomers in human serum.

Enantiomers of various solutes including several basic drugs and alpha-amino acids were analyzed by capillary electrophoresis in diluted human serum, and chloroquine and tryptophan were found to be well enantioseparated. In order to specify the protein responsible for enantioseparation, these drug enantiomers were analyzed in the presence of various serum protein fractions. The results indicated that albumin fraction caused enantioseparation but the alpha and beta -globulin mixed fraction, the gamma-globulin fraction and the alpha(1)-acid glycoprotein fraction did not exhibit any enantioseparation. The association constants between these drugs and albumin were roughly estimated based on our method. Approximate values were 1.50 x 10(3) and 1.85 x 10(3) M(-1) for chloroquine enantiomers, and 1.51 x 10(4) and 2.45 x 10(4) M(-1) for tryptophan enantiomers. The difference of the association constant values between the enantiomers was found to be 19% for chloroquine and 38% for tryptophan, when calculated based on the slower moving enantiomers.

Electrophoresis, Capillary↗

High-speed electrophoretic analysis of 1-phenyl-3-methyl-5-pyrazolone derivatives of monosaccharides on a quartz microchip with whole-channel UV detection.

1-Phenyl-3-methyl-5-pyrazolone (PMP) derivatives of monosaccharides were analyzed by electrophoresis on a quartz microchip with whole-channel UV detection. Rapid separation of PMP derivatives of aldopentoses was achieved by plain-zone electrophoresis in a neutral phosphate buffer with the height equivalent to a theoretical plate at the micrometer level. Zone electrophoresis as borate complexes was also successful for the separation of PMP derivatives of a few aldoses, which were separated within 1 min. Separation by microchip electrophoresis was compared to that by capillary electrophoresis, and the difference was discussed in terms of column efficiency and sample column capacity.

Antipyrine↗

Miniaturization in carbohydrate analysis.

Recent progress of microchip electrophoresis (ME) of carbohydrates is overviewed. Carbohydrate analysis by ME encounters difficulties such as lack of electric charge and deficiency of a chromophore/fluorophore in analyte molecules, however, it benefits from the accumulated knowledge of capillary electrophoresis (CE) and rapid separation of simple sugars also by ME, with high column efficiency comparable to CE, has become possible. Analysis at high pH, with electrochemical detection, is a promising approach because carbohydrates can be ionized by weak dissociation of the hydroxyl groups and the in situ formed ionic species can be effectively separated by the zone electrophoresis mode. The separated species can be sensitively monitored by electrochemical detection on a gold or copper electrode. Ionization as borate complexes and refractometric detection is also possible, though sensitivity is lower. Introduction of UV-absorbing or fluorescent tags is potentially useful but the time-consuming derivatization processes sacrifice the rapidity of ME. Examples of ME of carbohydrates as 1-phenyl-3-methyl-5-pyrazolone (PMP; for simple mono- and oligosaccharides with UV detection), 8-aminopyrene-1,3,6-trisulfonate (APTS; for oligosaccharides ladders with LIF detection), and 4-nitro-2,1,3-benzoxadiazole (NBD-F; for amino sugars and aminoalditols with LIF detection) derivatives are presented, with details of the analytical conditions. Since ME in a short separation channel enables rapid analysis within 1 min, it presents an ideal tool for clinical analysis, as shown in a few papers reporting protocols for specific blood glucose assay. Finally, the usefulness of microfluidic reactors and microarrays for enzyme-assisted carbohydrate analysis as well as glycan profiling is pointed out.

Carbohydrates↗

Simultaneous estimation of the association constants of glycoprotein glycoforms to a common protein by capillary electrophoresis.

The efficacy of our capillary electrophoresis method for simultaneous estimation of the association constants of glycoprotein glycoforms to a common target protein was demonstrated using ribonuclease and ovalbumin glycoforms as glycoform models and Lens culinaris agglutinin (LCA) as a protein model. The ribonuclease glycoforms were fairly well separated in the absence of LCA at pH 5.8, but the peaks were retarded without any change of separation profile in the presence of LCA, the retardation becoming greater as LCA concentration increased. The estimated values of apparent association constant (K(a)) were at the 10(6)M(-1) level for all the ribonuclease glycoforms, and there was no significant difference among glycoforms. The high-mannose-type N-glycans released from a mixture of ribonuclease glycoforms gave lower values of K(a) at the 10(4)-10(5)M(-1) level to the same protein, and the glycans having a larger number of the mannose residue gave larger K(a) values. These results imply that the glycan moiety in this glycoprotein might contribute to its binding to the protein, but the polypeptide core played the major role. In contrast, ovalbumin glycoforms gave poorly resolved peaks in the absence of LCA, but they were separated into several peaks in the presence of LCA, which were tentatively assigned based on the knowledge of affinity to this lectin, and K(a) values were estimated simultaneously. The estimated K(a) values were smaller than those of the ribonuclease glycoforms, suggesting the major role of the N-glycan moiety. Thus, capillary electrophoresis allowed simultaneous estimation of K(a) values under common conditions using small amounts of glycoform mixtures and proteins without prior isolation and purification. Comparison of the obtained values will provide useful information on the glycan structure-affinity correlation.

Amino Acid Sequence↗

Colominic acid: a novel chiral selector for capillary electrophoresis of basic drugs.

We introduced colominic acid as a new chiral selector for capillary electrophoresis of basic drugs. Use of a low concentration phosphate buffer containing this polysaccharide and a Polybrene/colominic acid double coated capillary allowed excellent separation of the enantiomers of primaquine, chloroquine and tryptophan. Other drugs giving partial enantioseparation include laudanosine and salbutamol. Capillary coating with Polybrene followed by colominic acid eliminated the problems of peak tailing and low reproducibility of migration time in uncoated capillaries. The optimum pH was in the acidic region but varied among drugs. A low capillary temperature of 16 degrees C and a colominic acid concentration of 9 w/v% are recommended for practical analysis of these drugs. Colominic acid preparations having higher molecular masses gave better enantioseparation, and N-acetylneuraminic acid, the component monosaccharide, did not give any enantioseparation.

Electrophoresis, Capillary↗