PubMed Health⌕ Search

Biomedical subjects

Syed G Shah

Publications and source records attributed to Syed G Shah.

9 recordsLinked to original sources

Aids to insertion: magnetic imaging, variable stiffness, and overtubes.

Inserting the colonoscope quickly and safely without undue patient discomfort is the primary aim of the colonoscopist. The inherently mobile, flexible and unpredictable nature of the colon means that looping occurs frequently during insertion and the colonoscopist must constantly strive to keep the instrument straight whilst at the same time advancing the tip towards the caecum. Colonoscopists have struggled with insertion for many years but recent developments described in this chapter have the potential to make insertion easier and more predictable.

Catheterization↗

Colonoscopic balloon dilation of Crohn's strictures: a review of long-term outcomes.

OBJECTIVE: To study the long-term outcomes of patients who have had endoscopic balloon dilation of Crohn's strictures. DESIGN: Retrospective case-note review over a 16-year period. PATIENTS: Patients with a Crohn's stricture causing obstructive symptoms and who had at least 6 months' follow-up data or a surgical outcome following dilation were sought; 59 patients (124 dilations) were identified. INTERVENTION: Patients all underwent endoscopic balloon dilation. RESULTS: Strictures were anastomotic in 53 patients (111 dilations) and de novo in six patients (13 dilations). The median stricture length was 3.0 cm. Median follow-up time was 29.4 months. Out of the total group, 41% of patients achieved long-term clinical benefit following dilation and in 17% after only a single dilation. The median number of dilations per patient was one. A total of 35 (59%) patients required surgery for their stricture during follow-up. There were two (1.6%) perforations as a result of dilation, one in an anastomotic stricture (managed conservatively) and one in a de-novo stricture (requiring surgery). There were no deaths. CONCLUSIONS: Colonoscopic balloon dilation of Crohn's strictures can achieve long-term clinical benefit in many patients. Repeat dilations are justified in initial non-responders. In this series, the procedure appears safe with low morbidity.

Adult↗

Total colonic dye-spray increases the detection of diminutive adenomas during routine colonoscopy: a randomized controlled trial.

BACKGROUND: Small adenomas may be missed during colonoscopy, but chromoscopy has been reported to enhance detection. The aim of this randomized-controlled trial was to determine the effect of total colonic dye spray on adenoma detection during routine colonoscopy. METHODS: Consecutive outpatients undergoing routine colonoscopy were randomized to a dye-spray group (0.1% indigo carmine used to coat the entire colon during withdrawal from the cecum) or control group (no dye). RESULTS: Two hundred fifty-nine patients were randomized, 124 to the dye-spray and 135 to the control group; demographics, indication for colonoscopy, and quality of the preparation were similar between the groups. Extubation from the cecum took a median of 9:05 minutes (range: 2:48-24:44 min) in the dye-spray group versus 4:52 minutes (range: 1:42-15:21 min) in the control group (p < 0.0001). The proportion of patients with at least 1 adenoma and the total number of adenomas were not different between groups. However, in the dye-spray group significantly more diminutive adenomas (<5 mm) were detected proximal to the sigmoid colon (p = 0.026) and more patients were identified with 3 or more adenomas (p = 0.002). More non-neoplastic polyps were detected throughout the colon in the dye-spray group (p = 0.003). There were no complications. CONCLUSIONS: Dye-spray increases the detection of small adenomas in the proximal colon and patients with multiple adenomas, but long-term outcomes should be studied to determine the clinical value of these findings.

Adenoma↗

The variable stiffness colonoscope: assessment of efficacy by magnetic endoscope imaging.

BACKGROUND: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffening mechanism. Thus, two studies were conducted to assess the potential benefit of the stiffening device and its optimal use. METHODS: In study 1, the effect of routinely stiffening the straightened variable-stiffness colonoscopes in the mid-descending colon was determined in 82 patients. Two insertions were performed (mid-descending colon to cecum) in each patient with and without application of the stiffening device (randomized). The time to negotiate the proximal colon (mid-descending to cecum), time to pass the variable-stiffness colonoscopes across the splenic flexure into the transverse colon, time to pass the right colon, and ancillary maneuvers used were recorded for each insertion. In study 2, consecutive patients, excluding any with previous colonic resection, were examined by using standard adult variable-stiffness colonoscopes. Real-time views of the procedure with magnetic endoscope imaging were recorded for all examinations, but procedures were randomized to be done either with (n = 88), or without (n = 87) the endoscopist viewing the magnetic endoscope imaging display. Whenever stiffening was applied, the anatomic location of the colonoscope tip and stiffness efficacy were recorded. RESULTS: In study 1, time taken to negotiate the proximal colon (p = 0.0041) and time to negotiate the splenic flexure (p = 0.006) were significantly shorter and ancillary maneuvers performed were fewer (p = 0.0014) with the stiffening device activated. In study 2, stiffening was used with similar frequency in patients examined with and without the magnetic endoscope imaging view, most commonly for passing the splenic flexure (71%), but also in the transverse colon (12%), right colon (9%), and sigmoid/descending colon (8%). Stiffening was significantly more effective when used in combination with magnetic endoscope imaging (69% with imager vs. 45% without imager; p = 0.0102). CONCLUSIONS: Overall, the variable-stiffness device used was effective in controlling looping 57% of the time. Activating maximum stiffness appears to be effective once the sigmoid colon has been negotiated and the colonoscope straightened with the tip in the proximal colon, reducing the number of ancillary maneuvers and shortening the insertion time through the proximal colon. Routine magnetic endoscope imaging further enhances the efficacy of the variable-stiffness colonoscopes by helping to identify the optimal time for stiffening.

Colon↗

Treatment with argon plasma coagulation reduces recurrence after piecemeal resection of large sessile colonic polyps: a randomized trial and recommendations.

BACKGROUND: Recurrence is frequent after piecemeal snare resection of large sessile colorectal polyps. The aim of this study was to evaluate the safety and efficacy of argon plasma coagulation (APC) in preventing recurrence when applied to the edge and base of the polypectomy site after apparently complete piecemeal resection. METHODS: Patients with large (>1.5 cm) sessile polyps removed by piecemeal snare cautery were placed into 2 groups. The first consisted of patients with polyps believed by the endoscopist to be completely excised. These patients were randomized to either no further therapy (control) or to APC of the rim and any residual mucosal or submucosal tissue in the base of the polypectomy site. The second group comprised patients in whom polyps, as judged by the endoscopist, were incompletely excised by snare polypectomy; APC was routinely applied without randomization to all visible remaining adenomatous tissue. Follow-up colonoscopy was performed within 3 months and 1 year; biopsy specimens were taken routinely from the resection site and further polypectomy was performed as indicated. RESULTS: There were fewer recurrences after APC in the randomized group (1/10 APC, 7/11 no APC; p = 0.02). In the group with initial incomplete snare polypectomy, recurrence was detected at 3 months in 6 of 13 despite APC. One patient was hospitalized with abdominal pain and minor rectal bleeding but required no intervention. There were no other episodes of significant late bleeding caused by piecemeal polypectomy. One patient was referred for surgery after unsuccessful endoscopic management. CONCLUSIONS: In patients with apparent complete endoscopic snare resection of large adenomas, postpolypectomy application of APC reduces adenomatous recurrence.

Aged↗

Effect of magnetic endoscope imaging on patient tolerance and sedation requirements during colonoscopy: a randomized controlled trial.

BACKGROUND: Pain during colonoscopy is primarily related to mesenteric stretching from looping of the colonoscope insertion tube. Prompt recognition and removal of loops reduces patient discomfort and may lessen sedation requirements. Magnetic endoscope imaging allows real-time visualization of the colonoscope during insertion. The effect of magnetic endoscope imaging on patient pain and sedation requirements was assessed in a prospective randomized controlled trial. METHODS: A total of 122 consecutive patients undergoing routine colonoscopy by a single experienced endoscopist were randomized to have the procedure performed either with the endoscopist viewing the imager display (n = 62), or without the imager view (n = 60). Procedures began with administration of hyoscine-N-butylbromide alone, and sedative medications (midazolam and meperidine) were self-administered by the patient with a patient-controlled analgesia pump. Cardiorespiratory parameters were recorded and patient pain was assessed with a 100-mm visual analogue scale. RESULTS: The number of attempts at straightening the colonoscope was fewer (median 8 [0-66] vs. 15 [0-87], p = 0.0076) and the duration of looping less (median 4.5 min [0-27.3 min] vs. 6.4 min [0-29.4 min]), when the endoscopist was able to see the imager view. The total number of patient demands (by patient-controlled analgesia) for medication (median 1 vs. 2.5) and total doses of midazolam (median 0.44 mg vs. 0.88 mg) and meperidine (median 16.75 mg vs. 32.5 mg) administered did not significantly differ between patients examined with or without the imager. Patient pain scores were also similar. CONCLUSIONS: Magnetic endoscope imaging allows accurate assessment and straightening of loops during colonoscopy, but without a significant reduction in patient requirements for sedative medication or improvement in patient tolerance. However, the dosages of sedation drugs used were small.

Adult↗

Use of video and magnetic endoscope imaging for rating competence at colonoscopy: validation of a measurement tool.

BACKGROUND: Counting the number of procedures performed provides at best a crude measure of technical competence in colonoscopy. The aim of this study was to develop and validate a qualitative and a quantitative score for measuring technical competency in colonoscopy using videotape evaluation. METHODS: Eighteen endoscopists with varying levels of experience were prospectively videotaped during colonoscope insertion. The following were recorded simultaneously: a closed circuit television view showing instrument handling, the endoscopic luminal view, and a continuous display of the colonoscope configuration (magnetic endoscope imaging). Videotapes were reviewed blindly and in random order by 3 experts. Performance in 3 categories was evaluated: (1) manipulation of instrument controls (0-10), (2) manipulation of the insertion tube (0-6) and (3) depth of insertion (0-4). A global assessment of competence was given for each endoscopist. RESULTS: Comparing the total scores as assessed by the 3 blinded experts, for each individual endoscopist, there were significant differences. However, there was good interobserver agreement and correlation between the individual scores and global assessment ratings of competence (p < 0.0001). CONCLUSIONS: The video assessment tool described appears to measure technical competence at colonoscopy, although in its present form it lacks reliability. Refinement of the score may improve reliability and deserves further evaluation.

Clinical Competence↗

Colonoscopy at a combined district general hospital and specialist endoscopy unit: lessons from 505 consecutive examinations.

Provisional reports from the Intercollegiate British Society of Gastroenterology National Colonoscopy audit show completion rates of 57-77% for the procedure and poor levels of training and supervision. We prospectively audited all aspects of colonoscopy performed at a combined district general hospital and specialist endoscopy unit. Details of referral, examination, endoscopist, complications and follow-up were recorded and patients were sent questionnaires for long-term follow-up. 505 patients (246 male) underwent colonoscopy by 27 different endoscopists. Their median age was 57 years (range 13-92) and 93% were outpatients. 64% patients were symptomatic and 36% were having surveillance or follow-up colonoscopy. The overall caecal intubation rate was 93%, with little difference between surgeons, physicians and experienced trainees (89%, 92%, 94%) and specialist endoscopists (98%). In only one case was an inexperienced trainee (<100 procedures) unsupervised. Pain scores estimated by the endoscopist were well matched with those given by the patient-medians 29 and 26 (maximum 100) respectively. Median satisfaction score was 96 (maximum 100). Polyp pick-up rate was 26.9% and there were 11 new cancers. 16 (3%) minor immediate complications were recorded-5 oversedation, 6 vasovagal attacks, 3 polypectomy haemorrhages and 2 mucosal injuries (neither requiring treatment). 3 patients died within 6 months of follow-up but no death was colonoscopy related. Completion rates in this setting were adequate for all endoscopists studied. Patient satisfaction with the procedure was high and very few immediate or long-term complications were encountered.

Adolescent↗