PubMed Health⌕ Search

Biomedical subjects

Sylvia Daunert

Publications and source records attributed to Sylvia Daunert.

At least 19 recordsLinked to original sources

Microfabrication of screen-printed nanoliter vials with embedded surface-modified electrodes.

A self-contained ion-selective sensing system within a nanoliter-volume vial has been developed by integrating screen printing, laser ablation, and molecular imprinting techniques. Screen printing and laser ablation are used in tandem to fabricate nanoliter-volume vials with carbon and Ag/AgCl ring electrodes embedded in the sidewalls. Using multisweep cyclic voltammetry, the surface of the carbon electrode can be modified with a polypyrrole film. By polymerizing pyrrole in the presence of nitrate, pores complementary to the nitrate anion in size, shape, and charge distribution are formed in the resulting film. Electrochemical cells modified with this nitrate-imprinted polypyrrole film show a near-Nernstian response to nitrate, and excellent reproducibility. The integration of molecular recognition and electrochemical response in the nanoliter vials is demonstrated by the detection of as little as 0.36 ng nitrate in nanoliter-volume samples. The integration of tailored molecular recognition within nanoliter vials via established fabrication and imprinting protocols should result in a number of nanosensor devices with applications in BioMEMS and micro total analysis systems.

Electrochemistry↗

Biosensing systems for the detection of bacterial quorum signaling molecules.

Bacterial quorum sensing (QS) is a cell-to-cell communication phenomenon that allows bacteria to control the expression of certain specialized genes depending on their cell population size. Signaling molecules such N-acylhomoserine lactones (AHLs) mediate the communication, and their concentration reflects the bacterial population density. Quorum sensing regulates several processes including bacterial pathogenicity. We developed a method for the rapid, sensitive, and quantitative detection of AHLs in biological samples such as saliva and stools. The method is based on whole-cell sensing systems that employ QS regulatory systems as recognition elements and the luxCDABE gene cassette as a reporter. The method proved to be reproducible when applied to real samples and was able to detect low analyte concentrations down to 1 x 10(-9) M without requiring extensive sample preparation. We envision that this novel biosensing system could be employed in the diagnosis and management of various bacteria-related disorders, thus supporting the use of quorum sensing molecules as potential biomarkers of disease. Due to cost-effectiveness and high throughput, these biosensing systems could be successfully employed as a new tool for the screening of novel drugs that target quorum sensing mechanisms.

Bacteria↗

Optimization of the xylan degradation activity of monolithic enzymatic membranes as a function of their composition using design of experiments.

The aim of this work was the development and optimization of enzymatic monolithic membranes with high catalytic activity for the degradation of xylan into xylooligosaccharides. The chemometric tool design of experiments has been utilized here for the first time for the optimization of the enzymatic activity of the monolithic membranes based on their constituents. The effect of three process variables, including the amount of various monomer contents and the porogenic solvents ratio, has been studied on the enzymatic activity of the resulted membranes. The experimental design chosen was a central face centred with six central points in order to obtain an orthogonal model, with the precision of the results being independent of the range of values considered for each parameter. The software Modde(c) 6.0 from Umetrics(c) was used to build and analyze the results of the experimental design using partial least squares regression. The optimization of the suggested model provided the best membrane composition to achieve maximum enzymatic activity, which can be related to the amount of enzyme immobilized on the monolithic membrane. The predictive capacity of the model was evaluated performing additional experiments.

Biodegradation, Environmental↗

ClcR-based biosensing system in the detection of cis-dihydroxylated (chloro-)biphenyls.

Polychlorinated biphenyls (PCBs) are a group of organic pollutants that are persistent when released into the environment. Among the metabolites of PCBs, dihydroxylated PCBs are also considered as toxic compounds. Various studies have shown that dihydroxylated PCBs affect the reproductive, immune, nervous, and endocrine systems. Detection of these chemicals in environmental and biological samples could provide first-hand information about their levels and lead to a better understanding of their role in toxicity. To that end, we developed a sensing system for the detection of dihydroxylated PCBs based on the clc operon. The Pseudomonas putida clc operon encodes a catabolic pathway for degradation of chlorocatechols, which are major metabolites of a large number of chlorinated compounds. In P. putida, the expression of these genes is regulated by a protein encoded by the gene clcR located upstream from the clcABD genes. We demonstrate here for the first time that dihydroxy PCBs can also induce the clc operon. Our sensing system employs P. putida bacteria harboring a plasmid in which the reporter gene, lacZ, is under the control of the regulatory protein ClcR. Consequently, when exposed to dihydroxy PCBs, the bacteria express beta-galactosidase in an amount related to the concentration of the corresponding dihydroxy PCB. Various dihydroxylated PCBs, differing in the number and position of chlorines and in the position of hydroxyls, were tested for their ability to induce expression of beta-galactosidase. Detection limits as low as 1 x 10(-6) mol L(-1) were obtained for various dihydroxylated PCBs.

Biosensing Techniques↗

Integration of microcolumns and microfluidic fractionators on multitasking centrifugal microfluidic platforms for the analysis of biomolecules.

This work demonstrates the development of microfluidic compact discs (CDs) for protein purification and fractionation integrating a series of microfluidic features, such as microreservoirs, microchannels, and microfluidic fractionators. The CDs were fabricated with polydimethylsiloxane (PDMS), and each device contained multiple identical microfluidic patterns. Each pattern employed a microfluidic fractionation feature with operation that was based on the redirection of fluid into an isolation chamber as a result of an overflow. This feature offers the advantage of automated operation without the need for any external manipulation, which is independent of the size and the charge of the fractionated molecules. The performance of the microfluidic fractionator was evaluated by its integration into a protein purification microfluidic architecture. The microfluidic architecture employed a microchamber that accommodated a monolithic microcolumn, the fractionator, and an isolation chamber, which was also utilized for the optical detection of the purified protein. The monolithic microcolumn was polymerized "in situ" on the CD from a monolith precursor solution by microwave-initiated polymerization. This technique enabled the fast, efficient, and simultaneous polymerization of monoliths on disposable CD microfluidic platforms. The design of the CD employed allows the integration of various processes on a single microfluidic device, including protein purification, fractionation, isolation, and detection.

Microfluidic Analytical Techniques↗

Novel reporter gene in a fluorescent-based whole cell sensing system.

A common problem encountered when using fluorescence detection in real samples analysis is that the matrix may contain compounds that autofluorescence or that can be excited at the wavelengths of commonly employed fluorescent reporter molecules. This causes an increase in background fluorescence, which in turn tends to compromise the detection limits of the system. To address this issue, we investigated the use of a reporter enzyme that produces fluorescent compounds, which can be excited at wavelengths that are not commonly encountered in compounds present in real samples. For that, a whole cell-based sensing system for arsenite that employs cobA as the reporter gene was developed. The system utilizes genetically engineered bacteria that incorporate the specificity of the ars operon with the sensitivity of the cobA gene. The cobA gene codes for uroporphyrinogen III methyltransferase that converts the substrate uroporphyrinogen (urogen) III into two fluorescent compounds sirohydrochlorin and trimethylpyrrocorphin. Urogen III is ubiquitous within the cell, however, because the cells use it for vitamin B12 and siroheme biosynthesis, this sensing system is limited by substrate availability. By supplementing the media with ALA, a precursor of urogen III, a more stable and reproducible response was obtained. We observed three excitation maxima at 357, 378, and 498 nm, with a single emission maximum at 605 nm. Excitation at 498 nm was selected because it results in less background interference as most endogenous substances are not active at this wavelength. Advantages and limitations of using the cobA gene in whole-cell sensing applications are presented.

Aminolevulinic Acid↗

Bioluminescence resonance energy transfer from aequorin to a fluorophore: an artificial jellyfish for applications in multianalyte detection.

In nature, the green light emission observed in the jellyfish Aequorea victoria is a result of a non-radiative energy transfer from the excited-state aequorin to the green fluorescent protein. In this work, we have modified the photoprotein aequorin by attaching selected fluorophores at a unique site on the protein. This will allow for in vitro transfer of bioluminescent energy from aequorin to the fluorophore thus creating an "artificial jellyfish". The fluorophores are selected such that the excitation spectrum of the fluorophore overlaps with the emission spectrum of aequorin. By modifying aequorin with different fluorophores, bioluminescent labels with different emission maxima are produced, which will allow for the simultaneous detection of multiple analytes. By examining the X-ray crystal structure of the protein, four different sites for introduction of the unique cysteine residue were evaluated. Two fluorophores with differing emission maxima were attached individually to the mutants through the sulfhydryl group of the cysteine molecule. Two of the fluorophore-labeled mutants showed a peak corresponding to fluorophore emission thus indicating resonance energy transfer from aequorin to the fluorophore.

Aequorin↗

Genetically engineered protein in hydrogels tailors stimuli-responsive characteristics.

Certain proteins undergo a substantial conformational change in response to a given stimulus. This conformational change can manifest in different manners and result in an actuation, that is, catalytic or signalling event, movement, interaction with other proteins, and so on. In all cases, the sensing-actuation process of proteins is initiated by a recognition event that translates into a mechanical action. Thus, proteins are ideal components for designing new nanomaterials that are intelligent and can perform desired mechanical actions in response to target stimuli. A number of approaches have been undertaken to mimic nature's sensing-actuating process. We now report a new hybrid material that integrates genetically engineered proteins within hydrogels capable of producing a stimulus-responsive action mechanism. The mechanical effect is a result of an induced conformational change and binding affinities of the protein in response to a stimulus. The stimuli-responsive hydrogel exhibits three specific swelling stages in response to various ligands offering additional fine-tuned control over a conventional two-stage swelling hydrogel. The newly prepared material was used in the sensing, and subsequent gating and transport of biomolecules across a polymer network, demonstrating its potential application in microfluidics and miniaturized drug-delivery systems.

Calcium↗

Investigation into the applicability of the centrifugal microfluidics platform for the development of protein-ligand binding assays incorporating enhanced green fluorescent protein as a fluorescent reporter.

The incorporation of a protein-ligand binding assay into a centrifugal microfluidics platform is described. The platform itself is a disc-shaped polymer substrate, upon which a series of microfluidic channels and reservoirs have been machined. Centrifugal microfluidics platforms require no internal moving parts, and fluid propulsion is achieved solely through rotation of the disc. Fluid flow is controlled by passive valves, the opening of which is dependent on the angular frequency of the rotating platform, the channel dimensions, and the physical properties of the fluid. To evaluate the effectiveness of incorporating a protein-based assay onto the centrifugal microfluidics analytical platform, a class-selective, homogeneous assay for the detection of phenothiazine antidepressants was employed. This class of drugs is known to bind to calmodulin, a calcium binding protein. Specifically, a fusion protein between calmodulin and enhanced green fluorescent protein was utilized. Calmodulin undergoes a conformational change upon binding to phenothiazines that alters the fluorescence properties of the attached fluorescent protein, which can be correlated to the concentration of the drug present. Another important aspect of this work was to study the efficacy of the platform to perform reconstitution assays. To do this, the biological reagent was dried on the platform and rehydrated to carry out the assay. The ability to prealiquot reagents on the platform should enhance its versatility and portability. The integration of protein-based assays in this platform should be useful in the design of analytical systems for high-throughput screening of pharmaceuticals and clinical diagnostics.

Antidepressive Agents↗

Whole-cell-reporter-gene-based biosensing systems on a compact disk microfluidics platform.

Biosensing systems such as reporter-gene-based whole-cell assays are increasingly finding applications in biological and environmental screening. A whole-cell approach to such analyses can provide valuable information about the bioavailable level of a compound of interest. These biosensing systems rely on the molecular recognition of a specific analyte by a regulatory protein and, therefore, can detect low levels of the target analyte. In this study, Escherichia coli cells containing plasmid pSD10 were engineered to sense the model target analytes arsenite and antimonite, the target analytes in this study. The biosensing system takes advantage of the recognition of the regulatory protein, ArsR, for arsenite and antimonite to produce the reporter protein, which in this case is GFPuv. The fluorescence emitted by the GFPuv in the cells can be directly related to the concentration of the analyte in the cell, making this biosensing system useful in the detection of arsenite and/or antimonite in a variety of samples. Miniaturization of biosensing systems can further enhance their utility by decreasing reagent consumption and analysis time and by allowing for the high-throughput screening of samples. To that end, we employed a microcentrifugal microfluidics platform that has low power, space, and reagent requirements, increased speed of detection, and the potential for portability. Herein, we demonstrate for the first time the adaptation of a whole-cell sensing system to a microcentrifugal microfluidics platform. Moreover, we were able to detect our target analytes in a rapid and sensitive manner compared to conventional sensing methods.

Antimony↗

Fluorescence-based sensing system for copper using genetically engineered living yeast cells.

A whole cell-based optical sensing system for copper was developed based on Saccharomyces cerevisiae cells harboring plasmid pYEX-GFPuv. The basis of this system was the ability of the transcriptional activator protein Ace1 present in S. cerevisiae to control the expression of the reporter protein, GFPuv. When copper ions are present in the sample, the Ace1 protein activates the cup1 promoter located upstream from the gfpuv gene in plasmid pYEX-GFPuv, thus inducing the production of GFPuv. The concentration of copper ions in the sample can then be related to the GFPuv expressed in the yeast. The amount of GFPuv produced in the system was determined by monitoring the fluorescence emitted at 507 nm after excitation at 397 nm. This system can detect copper at concentrations as low as 5 x 10(-7) M, and is selective for copper over a variety of metal ions, with the exception of silver. The applicability of this sensing system to different analytical platforms and in real samples is demonstrated.

Biological Assay↗

Phosphate binding protein as the biorecognition element in a biosensor for phosphate.

This work explores the potential use of a member of the periplasmic family of binding proteins, the phosphate binding protein (PBP), as the biorecognition element in a sensing scheme for the detection of inorganic phosphate (Pi). The selectivity of this protein originates from its natural role which, in Escherichia coli, is to serve as the initial receptor for the highly specific translocation of Pi to the cytoplasm. The single polypeptide chain of PBP is folded into two similar domains connected by three short peptide linkages that serve as a hinge. The Pi binding site is located deep within the cleft between the two domains. In the presence of the ligand, the two globular domains engulf the former in a hinge-like manner. The resultant conformational change constitutes the basis of the sensor development. A mutant of PBP (MPBP), where an alanine was replaced by a cysteine residue, was prepared by site-directed mutagenesis using the polymerase chain reaction (PCR). The mutant was expressed, from plasmid pSD501, in the periplasmic space of E. coli and purified in a single chromatographic step on a perfusion anion-exchange column. Site-specific labeling was achieved by attaching the fluorophore, N-[2-(1-maleimidyl)ethyl]-7-(diethylamino)coumarin-3-carboxamide (MDCC), to the protein through the sulfhydryl group of the cysteine moiety. Steady-state fluorescence studies of the MPBP-MDCC conjugate showed a change in the intensity of the signal upon addition of Pi. Calibration curves for Pi were constructed by relating the intensity of the fluorescence signal with the amount of analyte present in the sample. The sensing system was first developed and optimized on a spectrofluorometer using ml volumes of sample. It was then adapted to be used on a microtiter plate arrangement with microliter sample volumes. The system's versatility was finally proven by developing a fiber optic fluorescence-based sensor for monitoring Pi. In all three cases the detection limits for the analyte were in the sub-microMolar range. It was also demonstrated that the sensing system was selective for phosphate over other structurally-similar anions, paving the way for the design and development of a new family of biosensors utilizing the specific binding properties of periplasmic proteins.

Amino Acid Substitution↗

Fluorescence glucose detection: advances toward the ideal in vivo biosensor.

The importance of glucose monitoring for in vivo as well as for ex vivo applications has driven a vast number of scientific groups to pursue the development of an advanced glucose sensor. Such a sensor must be robust, versatile, and capable of the long-term, accurate and reproducible detection of glucose levels in various testing media. Among the different configurations and signal transduction mechanisms used, fluorescence-based glucose sensors constitute a growing class of glucose sensors represented by an increasing number of significant contributions to the field over the last few years. This manuscript reviews the progress in the development of fluorescence based glucose sensors resulting from the advances in the design of new receptor systems for glucose recognition and the utilization of new fluorescence transduction schemes.

Biosensing Techniques↗

Use of a gas-sensor array for detecting volatile organic compounds (VOC) in chemically induced cells.

An application of gas sensors for rapid bioanalysis is presented. An array of temperature-modulated semiconductor sensors was used to characterize the headspace above a cell culture. Recombinant Saccharomyces cerevisiae yeast cells, able to respond to 17 beta-estradiol by producing a reporter protein, were used as a model system. Yeast cells had the DNA sequence of the human estrogen receptor stably integrated into the genome, and contained expression plasmids carrying estrogen-responsive sequences and the reporter gene lac-Z, encoding the enzyme beta-galactosidase. The sensor-response profiles showed small but noticeable discrimination between cell samples induced with 17 beta-estradiol and non-induced cell samples. The sensor array was capable of detecting changes in the volatile organic compound composition of the headspace above the cultured cells, which can be associated with metabolic changes induced by a chemical compound. This finding suggests the possibility of using cross-selective gas-sensor arrays for analysis of drugs or bioactive molecules through their interaction with cell systems, with the advantage of providing information on their bioavailability.

Biosensing Techniques↗