PubMed Health⌕ Search

Biomedical subjects

T A Bensinger

Publications and source records attributed to T A Bensinger.

24 records · Page 2Linked to original sources

In vitro metabolism of packed erythrocytes stored in CPD-adenine.

In vitro metabolism of erythrocytes packed at 70 and 90 per cent hematocrits and stored in various CPD-adenine preservatives was studied. It was found that maintenance of acceptable levels of adenosine triphosphate (ATP) for the full 42 days of storage could be accomplished only if glucose levels were doubled from the standard 138.7 mM concentration to 277.5 mM level. If glucose levels were doubled, the amount of adenine could be decreased from 4.07 mM (0.50 mM final concentration) to 2.04 mM (0.25 mM final concentration) with maintenance of ATP at greater than 2.0 mumoles/g Hb. 2,3-diphosphoglycerate concentrations were essentially absent by 21 days in the various media studies. Thus, in vitro levels of ATP appear to be maintained at acceptable levels in a CPD media modified to contain 2 times glucose and 2.04 mM adenine.

Adenine↗

The effect of agitation on in vitro metabolism of erythrocytes stored in CPD-adenine.

Agitation of blood stored in plastic containers has been reported to lead to improved posttransfusion survival and it has been found that, in some media, agitation has improved erythrocyte 2,3-diphosphoglycerate (2,3-DPG) levels. Using CPD II media (CPD with 277.5 mM glucose and 2.04 mM adenine), we were not able to identify any improvement in levels of adenosine triphosphate, 2,3-DPG or glucose in whole blood under various agitation conditions when compared with nonagitated control. The 2,3-DPG level was moderately improved through 28 days in the 90 per cent hematocrit packed erythrocytes but the results were not considered to be significantly beneficial to warrant agitation. Thus, the application of agitation to the CPD II blood storage system was of no great benefit in improving metabolic intermediate levels.

Adenine↗

Additional studies concerning the metabolism of packed erythrocytes in CPD adenine.

Studies concerning the relationship between glucose level, hematocrit to which cells were packed (within three hours of initial collection) and adenosine triphosphate (ATP) concentration were undertaken in CPD supplemented with adenine (0.25 mM final concentration). It was found that apparently adequate ATP levels could be maintained in 90 per cent hematocrit packed units at 42 days only if glucose was present in amounts 1.5 times or greater than that provided by CPD. Less tight packing of the units to 70 and 80 per cent hematocrit maintained ATP at greater than 50 per cent of the initial level for a full 42 days of storage when 1.25 times the usual glucose concentration was present in the initial anticoagulant. No difference in 2,3-diphosphoglycerate or pH was found in any of the modified media under study.

Adenine↗

The in vivo survival of red blood cells stored in modified CPD with adenine: report of a multi-institutional cooperative effort.

In order to provide data in support of licensure applications for citrate-phosphate-dextrose (CPD) supplemented with adenine, a multi-institutional cooperative effort was organized to determine survivability of red blood cells subjected to prolonged liquid storage. Two manufacturers supplied plastic multiple bag blood storage containers prefilled with modified CPD (glucose 25% greater than the normal concentration) supplemented with adenine (17.0 to 17.3 mg per 63 ml of anticoagulant; 0.25 millimolar approximate final concentration when diluted with 450 ml of whole blood for 35 days showed a mean survival of 80.53 +/- 6.44 per cent (1 SD). Both red blood cell and supernatant plasma biochemical characteristics were comparable to those reported for whole blood stored for 21 days in either acid-citrate-dextrose (ACD) or CPD. Red blood cells from 19 units stored as concentrates for 35 days (Hct 75.03 +/- 3.74%) had a mean survival of 71.38 +/- 10.3 per cent with considerable interdonor variation in survival and interlaboratory variation in some biochemical characteristics. Red blood cells from eight units stored as concentrates (Hct 75.38 +/- 4.30%) for 28 days showed a mean survival of 83.97 +/- 6.10 per cent and biochemical characteristics comparable to those reported for red blood cell concentrates stored in CPD or ACD for 21 days. Modified CPD with adenine as formulated offers an improved anticoagulant for blood banking by extending the permissible red blood cell storage period.

Adenine↗