PubMed Health⌕ Search

Biomedical subjects

T A Burdon

Publications and source records attributed to T A Burdon.

21 records · Page 2Linked to original sources

Durability of porcine valves at fifteen years in a representative North American patient population.

Isolated aortic (n = 857) or mitral (n = 793) valve replacement with a porcine bioprosthesis was performed in 1650 patients between 1971 and 1980. Follow-up (total = 12,012 patient-years) extended to more than 15 years and was 96% complete. Patient age ranged from 16 to 87 years; mean age was 59 +/- 11 years (+/- 1 standard deviation) for the aortic valve replacement cohort and 56 +/- 12 years for the mitral valve replacement cohort. The operative mortality rates were 5% +/- 1% (+/- 70% confidence limits) and 8% +/- 1%, respectively, for the aortic and mitral subgroups. Estimated freedom from structural valve deterioration (+/- 1 standard error of the mean) after 10 and 15 years was significantly higher for the aortic than for the mitral valve replacement subgroup (85% +/- 0.4% and 63% +/- 3% versus 78% +/- 2% and 45% +/- 3%, respectively, p = 0.001). Reoperation-free actuarial estimates were also significantly greater for the aortic valve replacement cohort: 83% +/- 2% and 57% +/- 3% versus 78% +/- 2% and 43% +/- 3% for mitral valve replacement at 10 and 15 years, respectively. The mortality rate for reoperative aortic valve replacement was 11% +/- 1%; it was 8% +/- 1% for reoperative mitral valve replacement. Importantly, the estimates of freedom from valve-related death (including sudden, unexplained deaths) were relatively high at 10 and 15 years: 78% +/- 2% and 69% +/- 3% in the aortic cohort and 74% +/- 2% and 63% +/- 3% in the mitral cohort (p = not significant). Excluding sudden, unexplained deaths, these estimates were 81% +/- 3% (aortic) and 73% +/- 4% (mitral) at 15 years. Thromboembolism-free rates were 84% +/- 3% (aortic) and 78% +/- 6% (mitral) at 15 years, and freedom from anticoagulant-related hemorrhage was 96% +/- 1% and 89% +/- 2%, respectively. At the time of current follow-up, 13% of patients having aortic valve replacement and 50% of patients having mitral valve replacement were receiving warfarin sodium. The hazard functions for thromboembolism and prosthetic valve endocarditis were constant and remained less than 1%/pt-yr over the entire follow-up period.(ABSTRACT TRUNCATED AT 400 WORDS)

Actuarial Analysis↗

Endoscopic guided percutaneous tracheostomy: early results of a consecutive trial.

Percutaneous tracheostomy is increasingly being used for patients needing prolonged ventilatory support. The purpose of this study was to assess the feasibility of widespread application of endoscopic guided percutaneous tracheostomy. Sixty-one consecutive ICU patients requiring prolonged mechanical ventilation underwent bedside endoscopic guided percutaneous tracheostomy. Using a modified Ciaglia technique, a #6-10 tracheostomy tube was introduced between the second and third tracheal rings. Bronchoscopic transillumination facilitated identification of the appropriate tracheostomy site, and verified satisfactory placement of dilators and tracheostomy tube. There was one procedure-related death due to arrhythmia. Procedure-related complications included (n = 7): bleeding (controlled with local pressure), two infections, two cuff tears, and two obstructions of the tracheal tube. The tracheostomy was eventually removed in 13 patients. Bronchoscopic evaluation of three patients at 4 months post-tracheostomy removal was normal and there has been no clinical evidence suggestive of tracheal stenosis in the remaining ten extubated patients. There was a 50% reduction in cost when compared to operative tracheostomy. Percutaneous tracheostomy is a simple, safe, cost-effective bedside procedure for critically ill ventilator-dependent patients. Endoscopic guidance appears to increase the safety of this procedure and may prevent complications of pneumothorax, subcutaneous emphysema, and paratracheal false passage previously reported with blinded percutaneous methods.

Adult↗

Port-access bilateral internal mammary artery grafting for left main coronary artery disease: canine feasibility study.

BACKGROUND: To extend the applications of minimal access cardiac surgery, an endovascular cardiopulmonary bypass (CPB) system that allows cardioplegia delivery and cardiac venting was used to perform bilateral internal mammary artery (IMA) bypass grafting in six dogs. METHODS: The left IMA (LIMA) was taken down thoracoscopically from three left lateral chest ports, followed by the right IMA (RIMA) from the right side. One left-sided port was extended medially 5 cm with or without rib resection, to expose the pericardium. Both IMAs were divided and exteriorized through the left anterior mediastinotomy. Flow and pedicle length were satisfactory in all cases. Femoral-femoral bypass was used and the heart arrested with antegrade delivery of cardioplegic solution via the central lumen of a balloon catheter inflated to occlude the ascending aorta. All anastomoses were made through the mediastinotomy under direct vision. In five studies the RIMA was attached to the left anterior descending artery (LAD) and the LIMA to the circumflex, and in one study the RIMA was tunneled through the transverse sinus to the circumflex and the LIMA was anastomosed to the LAD. All animals were weaned from CPB in sinus rhythm without inotropes. CPB duration was 108 +/- 27 minutes (mean +/- SD) and the clamp duration was 54 +/- 10 minutes. RESULTS: Preoperative and postoperative cardiac outputs were 2.9 +/- 0.71/min and 2.4 +/- 0.31/min, respectively (p = NS), and corresponding pulmonary artery occlusion pressures were 6 +/- 3 mmHg and 7 +/- 2 mmHg, respectively (p = NS). All 12 grafts were demonstrated to be fully patent. Postmortem examination revealed well aligned pedicles and correctly grafted target vessels. CONCLUSION: This canine model demonstrates the potential for a less invasive approach to the surgical management of left main coronary artery disease in humans.

Animals↗