PubMed Health⌕ Search

Biomedical subjects

T A Klar

Publications and source records attributed to T A Klar.

4 recordsLinked to original sources

Gold nanoparticles quench fluorescence by phase induced radiative rate suppression.

The fluorescence quantum yield of Cy5 molecules attached to gold nanoparticles via ssDNA spacers is measured for Cy5-nanoparticle distances between 2 and 16 nm. Different numbers of ssDNA per nanoparticle allow to fine-tune the distance. The change of the radiative and nonradiative molecular decay rates with distance is determined using time-resolved photoluminescence spectroscopy. Remarkably, the distance dependent quantum efficiency is almost exclusively governed by the radiative rate.

Carbocyanines↗

Fluorescence quenching of dye molecules near gold nanoparticles: radiative and nonradiative effects.

The radiative and nonradiative decay rates of lissamine dye molecules, chemically attached to differently sized gold nanoparticles, are investigated by means of time-resolved fluorescence experiments. A pronounced fluorescence quenching is observed already for the smallest nanoparticles of 1 nm radius. The quenching is caused not only by an increased nonradiative rate but, equally important, by a drastic decrease in the dye's radiative rate. Assuming resonant energy transfer to be responsible for the nonradiative decay channel, we compare our experimental findings with theoretical results derived from the Gersten-Nitzan model.

Biophysical Phenomena↗

Breaking Abbe's diffraction resolution limit in fluorescence microscopy with stimulated emission depletion beams of various shapes.

We report on the generation of various hole-centered beams in the focal region of a lens and investigate their effectiveness to break the diffraction barrier in fluorescence microscopy by stimulated emission. Patterning of the phase of the stimulating beam across the entrance pupil of the objective lens produces point-spread-functions with twofold, fourfold, and circular symmetry, which narrow down the focal spot to 65-100 nm. Comparison with high-resolution confocal images exhibits a resolution much beyond the diffraction barrier. Particles that are only 65-nm apart are resolved with focused light.

Journal Article↗

Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission.

The diffraction barrier responsible for a finite focal spot size and limited resolution in far-field fluorescence microscopy has been fundamentally broken. This is accomplished by quenching excited organic molecules at the rim of the focal spot through stimulated emission. Along the optic axis, the spot size was reduced by up to 6 times beyond the diffraction barrier. The simultaneous 2-fold improvement in the radial direction rendered a nearly spherical fluorescence spot with a diameter of 90-110 nm. The spot volume of down to 0.67 attoliters is 18 times smaller than that of confocal microscopy, thus making our results also relevant to three-dimensional photochemistry and single molecule spectroscopy. Images of live cells reveal greater details.

Escherichia coli↗