PubMed Health⌕ Search

Biomedical subjects

T A Tasciyan

Publications and source records attributed to T A Tasciyan.

9 recordsLinked to original sources

Brain volume measurements in patients with human T-cell lymphotropic virus-1-associated tropical spastic paraparesis.

Human T-cell lymphotropic virus (HTLV)-1 is associated with a chronic progressive neurologic disease known as HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP) that affects 0.2% to 3% of HTLV-1-infected people. The authors aimed at exploring, in vivo, whether brain volume reduction occurs in patients with HAM/TSP through the use of magnetic resonance imaging (MRI). T1 pre/postcontrast spin echo-weighted images (WIs) and T2WIs of the brain were obtained in 19 HAM/TSP patients and 14 age-and sex-matched healthy volunteers. Both patients and healthy individuals were imaged at a 1.5-Tesla magnet by employing a conventional head coil. Focal T1 and T2 abnormalities were calculated and two measurements of brain parenchyma fraction (BPF) were obtained by using SIENAx (Structural Image Evaluation,using Normalisation, of Atrophy; University of Oxford, Oxford, UK) and MIPAV (Medical Image Processing, Analysis, and Visualization; National Institutes of Health, Bethesda, USA) from T1WIs. No significant differences in BPF were found between patients and healthy subjects when using either SIENAx or MIPAV. Analysis of individual patients detected that BPF was lower by 1 standard deviation (SD) relative to patients' average BPF in one patient. The authors conclude that reductions in BPF do not occur frequently in patients with HAM/TSP. However, the authors believe that one individual case of significant brain atrophy raises the question as to whether atrophy selectively targets the spinal cord of HAM/TSP patients or may involve the brain as well. A larger patient population analyzing regional brain volume changes could be helpful in determining whether brain atrophy is a marker of disease in patients with HAM/TSP.

Adult↗

Interferon-beta-1b effects on re-enhancing lesions in patients with multiple sclerosis.

Interferon-beta (IFNbeta) reduces the number and load of new contrast-enhancing lesions (CELs) in patients with multiple sclerosis (MS). However, the ability of IFNbeta to reduce lesion sizes and re-enhancements of pre-existing CELs has not been examined extensively. Activity of contrast re-enhancing lesions (Re-CELs) and contrast single-enhancing lesions (S-CELs) were monitored in ten patients with relapsing-remitting (RR) MS. These patients underwent monthly post-contrast magnetic resonance imaging (MRIs) for an 18-month natural history phase and an 18-month therapy phase with subcutaneous IFNbeta-1b, totaling 37 images per patient. The activity was analysed using the first image as a baseline and registering subsequent active monthly images to the baseline. There was a 76.4% reduction in the number of CELs with IFNbeta therapy. The decrease was greater (P = 0.003) for S-CELs (82.3%) than for Re-CELs (57.4%). S-CELs showed no changes in durations of enhancement and maximal lesion sizes with treatment. Exclusively for Re-CELs, IFNbeta-1b significantly decreased maximal lesion sizes, total number of enhancement periods and total months of enhancement. Thus, IFNbeta appears to be effective in reducing the degree of severity of inflammation among Re-CELs, as reflected by their reduced maximal lesion sizes and durations of enhancement.

Adjuvants, Immunologic↗

Partial angle inversion recovery (PAIR) MR imaging: spin-echo and snapshot implementation.

The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was calculated from the solution to the Bloch equations and was utilized to determine the contrast behavior of a lesion/liver model. Theoretical and experimental results were consistent with each other. With the TI chosen to suppress the fat signal, optimization of the excitation pulse flip angle results in an increase in lesion/liver contrast or allows reduction in imaging time which, in turn, can be traded for an increased number of averages. This, in normal volunteers, improved spleen/liver contrast-to-noise ratio (9.0 vs. 5.7, n = 8, p less than 0.01) and suppressed respiratory ghosts by 33% (p less than 0.01). Reducing or increasing the inversion pulse from 180 degrees results in shorter TI needed to null the signal from the tissue of interest. Although this decreases the contrast-to-noise ratio, it can substantially increase the number of sections which can be imaged per given TR in conventional IR imaging or during breathold in the snapshot IR (turboFLASH) technique. Thus, the optimization of RF pulses is useful in obtaining faster IR images, increasing the contrast and/or increasing the number of imaging planes.

Abdomen↗

Fast limited flip angle MR subtraction angiography.

A fast MR angiography method is introduced that is capable of generating difference images of blood vessels in scan times of 10-20 s. This is an order of magnitude faster than many previous methods. The fundamental concept of this approach is to use cardiac gating and acquire several phase encodings at least twice during each cardiac cycle using limited flip angles (LFAs) and repetition times in the 20 to 50 ms range. The encodings acquired during diastole are subtracted from those acquired during systole to generate the difference image. The contrast in the difference image is due both to the influx of unsaturated spins and to the loss of phase coherence of systolic blood moving at high velocity along a magnetic gradient. The systolic peak of the cardiac cycle is determined during reconstruction by shifting the systolic and diastolic "windows" until the difference signal is maximized. Ghost artifacts due to pulsatile flow are eliminated by a phase reordering technique similar in concept to those developed for suppression of breathing artifacts. Arteries in thick slices are successfully imaged and initial in vivo results are presented.

Angiography↗

Color flow-encoded MR imaging.

Magnetic resonance phase images can enable identification of any type of motion, including the velocity and direction of flow, and thus provide valuable supplements to magnitude images, which depict stationary tissue most effectively. A method is described for the simultaneous display of phase and magnitude by color encoding the phase data and superimposing it on the magnitude image to facilitate clinical interpretation. Color-encoded data not only depict the location and direction of flow along specific axes but can also provide relative velocity information through shades of color. Implementation of the technique is described, and the factors to be considered during interpretation of color flow-encoded images are discussed.

Aorta↗

Chemical shift artifact along the section-select axis.

Chemical shift artifact (CSA), familiar to radiologists along the frequency-encoding axis, also occurs along the section-select axis. The authors observed a case in which CSA mimicked a renal mass. Subsequent retrospective analysis of 50 abdominal magnetic resonance (MR) imaging studies was performed to assess occurrence of CSA adjacent to the upper and lower renal poles. CSA along the section-select axis was observed in 76% of cases and adjacent to 39% of all renal poles imaged. CSA along the section-select axis is common in abdominal MR imaging and may occasionally mimic disease.

Abdomen↗

Pulsatile flow artifacts in fast magnetization-prepared sequences.

Fast magnetization-prepared magnetic resonance imaging sequences allow clinical acquisitions in about 1 second, with the preparation phase providing the desired contrast. Pulsatile flow artifacts, although reduced by rapid acquisition, can degrade image quality. The authors explore the causes of aortic pulsatile flow artifacts in inversion-recovery-prepared acquisitions of the abdomen, taking into consideration various parameters. The flow signal within an 8-mm-thick section was simulated and subsequently Fourier transformed to determine the location and extent of flow artifacts. Results of simulations were validated with abdominal images of human subjects. Recording all encodings within one cardiac cycle reduced pulsatile flow artifacts in nonsegmented acquisitions with sequential phase-encoding order, regardless of the location of magnetization preparation within the cardiac cycle. In segmented acquisitions, however, the sequential order always increased flow artifacts. To reduce the artifacts in short TI acquisitions, the magnetization should be prepared during diastole. In clinical acquisitions, flow artifacts were further reduced by modifying the phase-encoding scheme.

Aorta, Abdominal↗

MR subtraction angiography with a matched filter.

The technique of matched filtering (MF) has been used in the past with X-ray digital subtraction angiography as a method of improving signal-to-noise ratio (SNR) in subtraction angiographic images. In this work we describe how MF can be applied to a series of images produced by cinematographic magnetic resonance (cine MR) to produce angiographic images. Likewise, a simple subtraction image can be formed by subtracting an image in which flow is not well visualized from an image at the same location but with flow visualization. Theory predicts that a subtraction image resulting from the MF technique will yield typical SNR improvements of 60% over results from simple subtraction. Twenty-one studies of the human popliteal, canine aorta, and canine carotid artery were undertaken in which MF was compared with simple subtraction. It was determined that cine MR can be used to produce subtraction angiographic images and that MF can produce a modest improvement in SNR over simple subtraction.

Animals↗

Two-dimensional pulsatile hemodynamic analysis in the magnetic resonance angiography interpretation of a stenosed carotid arterial bifurcation.

A two-dimensional pulsatile hemodynamic analysis based on the finite-element technique was performed on a minimally stenosed carotid artery to identify the possible explanation for the differences in the x-ray and magnetic resonance carotid angiograms of a patient. The magnetic resonance angiogram was obtained by applying the maximum intensity projection algorithm to axial slices, acquired using the time-of-flight principle. The differences in the x-ray and magnetic resonance depictions were interpreted based on velocity profile, wall shear stress, and streamline data provided by the hemodynamic analysis. The specific contribution of the stenosis was further isolated from that of the bifurcation by comparing the flow patterns within the stenotic artery with those of its normal counterpart. The Doppler spectral velocity wave form of the patient constituted the basis for the pulsatile flow velocity specification. The analysis took into consideration the non-Newtonian viscosity of blood. The numerical procedure was validated through different convergence criteria and through shear stress comparisons. The importance of hemodynamic analyses in relation to magnetic resonance angiography was further discussed along with possible shortcomings of the technique.

Angiography↗