PubMed Health⌕ Search

Biomedical subjects

T Altzitzoglou

Publications and source records attributed to T Altzitzoglou.

17 recordsLinked to original sources

EC intercomparisons for laboratories monitoring environmental radioactivity.

International measurement comparisons are organised regularly for EU laboratories involved in monitoring radioactivity, with emphasis on meeting routine measurement conditions. Using the recent comparison of 137Cs in air filters as an example, the whole cycle is described: establishment of traceable reference values, spiking of individual filters for the comparison and their quality assurance, treatment and measurement of filters in the participating laboratories and evaluation of comparison results. The treatment of an individual result, deviating widely from the reference value, is discussed. Monte-Carlo simulations allow to estimate the maximum errors possibly made due to a non-suitable measurement geometry.

Air Pollutants, Radioactive↗

Intercomparison of efficiency transfer software for gamma-ray spectrometry.

The EUROMET project 428 examines efficiency transfer results for Ge gamma-ray spectrometers when the efficiency is known for a reference point source geometry. For this, different methods are used, such as Monte Carlo simulation or semi-empirical computation. The exercise compares the application of these methods to the same selected experimental cases to determine the usage limitations versus the requested accuracy. For carefully examining these results and trying to derive information for improving the computation codes, this study was limited to a few simple cases. The first part concerns the simplest case of geometry transfer, i.e., using point sources for 3 source-to-detector distances: 2, 5 and 20 cm; the second part deals with transfer from point source geometry to cylindrical geometry with three different matrices. The general conclusion is that the deviations between the computed results and the measured efficiencies are mostly within 10%. The quality of the results is rather inhomogeneous and shows that these codes cannot be used directly for metrological purposes. However, most of them are operational for routine measurements when efficiency uncertainties of 5-10% can be sufficient.

Journal Article↗

Standardisation of 204Tl at IRMM

IRMM participated in a recent international comparison for the standardisation of a 204Tl solution organised by BIPM. The activity concentration of the 204Tl solution was measured at IRMM using 3 independent methods; Liquid Scintillation Counting using the CIEMAT/NIST method, 4pi-CsI counting and 4pibeta counting using a large pressurised proportional counter. This article describes the measurements in detail and discusses potential problems in the standardisation of 204Tl.

Journal Article↗

Low-level radioactivity measurements in an ocean shellfish matrix.

Reference marine biological samples are necessary to test the performance of the analytical methods employed in surveying and monitoring radioactive materials in the sea. The measurement of artificial and natural radionuclide activity concentrations in ocean shellfish material by nondestructive ultra low-level gamma-ray spectrometry in an underground laboratory is reported. The material analysed, a composite material made of Irish Sea and White Sea mussel and Japan Sea oyster, was prepared by the National Institute of Standards and Technology (NIST).

Animals↗

Analysis of triple-label samples by liquid scintillation spectrometry.

The simultaneous analysis of three radionuclides present in a sample is demonstrated. The approach requires fitting a series of counting data acquired over a period of time to a triple exponential mathematical expression. The use and advantages of the method are illustrated for the case of the standardisation of 32P in the presence of 33P and 35S by 4pi-beta liquid scintillation spectrometry. The effects of sample preparation, chemical quenching and different activity ratios were studied.

Algorithms↗

Characterisation of reference materials for radioactivity with assigned values traceable to the SI units.

The Institute for Reference Materials and Measurements participates in an IAEA co-ordinated project to upgrade Analytical Quality Control Services intercomparison materials to reference materials. The principal objective is to ensure that assigned property values are traceable to the International System of Units. General principles and practical mechanisms for achieving this traceability are described.

Journal Article↗

Standardisation of low-activity actinide solutions by alpha-particle counting at a defined solid angle.

In the frame of an IAEA co-ordinated research project 232U, 236Pu and 229Th tracers were standardised by alpha-particle counting at a defined solid angle. The aim of this project was to assign property values that are traceable to the International System of Units (SI). This article depicts the standardisation of the tracers, elaborating on problems related to low activity and interference from daughter nuclides. The activity concentrations of 232U, 236Pu and 229Th were found to be, respectively (734+/-4), (142.0+/-0.9) and (528.2+/-2.6) Bq g(-1), at reference date (1 January 2003).

Journal Article↗

Validation of methods for the determination of radium in waters and soil.

This article describes the advantages and disadvantages of several analytical methods used to prepare the alpha-particle source. As a result of this study, a new method combining commercial extraction and ion chromatography prior to a final co-precipitation step is proposed. This method has been applied and validated on several matrices (soil, waters) in the framework of international intercomparisons. The integration of this method in a global procedure to analyze actinoids and radium from a single solution (or digested soil) is also described.

Alpha Particles↗

Aspects of sample preparation for the determination of actinoids in soil.

In the frame of the re-certification measurements of the IAEA-375 soil reference material the activity concentration of four actinoids (U, Th, Pu and Am) was determined. The method is based on microwave digestion or aqua regia leaching, separation by extraction chromatography and alpha-particle counting source preparation by co-precipitation or electro-deposition. This article describes some of the problems encountered during the validation of the sample preparation method and their solutions.

Actinoid Series Elements↗

Self-absorption correction in standardisation of 204Tl.

In the frame of the CCRI(II) (Consultative Committee for Ionizing Radiation at the BIPM) working group on 204Tl, dedicated to investigate the problem and explain the reasons for the discrepancy between methods in standardisation of 204Tl, IRMM was assigned the task of studying the influence of self-absorption in solid sources of 204Tl. This was investigated by measuring the activity of quantitative solid sources of different carrier content, prepared by employing a special source drying technique, developed at IRMM. The activity of the solid sources was determined using a 4pi pressurised proportional counter. The self-absorption was calculated using the activity determined from liquid scintillation spectrometry, unaffected by self-absorption, as the reference value. After correction for foil absorption and non-detected X-rays, the self-absorption showed a linear relation to the logarithm of the dry mass of the source. For a typical source, the self-absorption correction for 204Tl was found to be as high as 8%. This article describes a way to minimise and correct for self-absorption in solid sources of 204Tl or nuclides with similar decay properties.

Journal Article↗

Standardisation of 89Sr using three different methods.

Three independent methods were used to standardise a 89Sr solution within the frame of an international comparison organised by BIPM/CCRI(II): 4pi liquid scintillation (LS) spectrometry, based on the CIEMAT/NIST efficiency tracing method, and direct activity measurements with a windowless 4pi CsI(Tl)-sandwich spectrometer and a 4pi pressurised gas proportional counter. Quantitative solid point-like sources were prepared paying special attention during the source drying phase. The impurities in the original solution were measured and corrected for in the results of all three methods. The activity concentration of 89Sr was found to be 26.21 +/- 0.08 kBq g(-1). A new half-life value for 89Sr of 50.61 +/- 0.05 days was determined from the LS measurements. The measurement methods, including the impurity measurements, are described and the results compared. considering the advantages and disadvantages of each method.

Journal Article↗

Development of the NIST bone ash standard reference material for environmental radioactivity measurement.

The bone ash standard reference material (SRM), a blend of 4% contaminated human bone and 96% diluent bovine bone, has been developed for radiochemical method validation and quality control for radio-bone analysis. The massic activities of 90Sr, 226Ra, 230Th, 232Th, 234U, 235U, 238U, 238Pu, (239 + 240)Pu and (243 + 244)Cm were certified using a variety of radiochemical procedures and detection methods. Measurements confirmed undetectable radionuclide heterogeneity down to a sample size of 5 g. thereby implying adequate blending of particulate materials with dilution factors of up to 17,900. The results among most of the intercomparison laboratories and their methods were consistent. Disequilibrium was observed for decay chains: 234U(0.67 mBq/g)-230Th(0.47 mBq/g)-226Ra(15.1 mBq/g)-210Pb(23 mBq/g)-210Po(13 mBq/g) and 232Th(0.99 mBq/g)-228 Ra(6.1 mBq/g)-228Th(7.1 mBq/g). The disequilibria were the results of mixing occupationally contaminated human bone with natural bovine bone and the fractionation during internal biological processes. The massic activity of 210Pb, 228Th and 241Am were not certified because of insufficient 228Ra and 241Pu data and lack of knowledge in how 222Rn and its daughters will be fractionated in the SRM bottle over time.

Animals↗

Measurement of 90Sr in bone ash.

Bone is a critical organ for the accumulation of many radionuclides, including 90Sr. A bone ash has been prepared by NIST to become a standard reference material and the assaying of the 90Sr activity concentration is reported. A radiochemical procedure, based on extraction chromatography using a crown ether, has been developed to separate Sr from the bone ash. The natural Sr content of the bone ash has been determined by isotope dilution inductively coupled plasma mass spectrometry. The 90Sr activity concentration has been measured by low-level liquid scintillation counting.

Animals↗