PubMed Health⌕ Search

Biomedical subjects

T Andrew Bowdle

Publications and source records attributed to T Andrew Bowdle.

11 recordsLinked to original sources

Intraoperative epoprostenol and nitric oxide for severe pulmonary hypertension during orthotopic liver transplantation: a case report and review of the literature.

BACKGROUND: The presence of pulmonary hypertension in patients scheduled for liver transplantation requires a comprehensive perioperative heart evaluation and treatment with epoprostenol (prostacycline) infusion until a liver donor becomes available. We contended that intraoperative attenuation of severe pulmonary hypertension could be achieved by epoprostenol infusion combined with nitric oxide inhalation. CASE REPORT: A 49 years old man with end stage liver disease secondary to hepatitis C and ethanol abuse presented for orthotopic liver transplantation. The case was complicated by severe pulmonary hypertension. Preoperative epoprostenol, at doses ranging from 6 to 26 ng.kg(-1).min(-1), was infused during the induction of anesthesia. Although lower than before (>70 mmHg), post-induction pulmonary pressure (by Swan-Ganz catheter) was 62/30 mmHg. Prior to surgical incision nitric oxide (NO) by inhalation was commenced, increasing the concentration from 10 to 40 ppm; pulmonary artery pressure (PAP) then declined to 55/25 mmHg. Before starting reperfusion of the transplanted liver, NO concentration was increased to 80 ppm: this allowed completion of the procedure with PAP at 32/16 mmHg. Real time transesophageal echocardiography indicated improvement in right heart function due to NO. Following surgery, NO was continued for 10 hs at a concentration of 40 ppm and the patient was then extubated. Epoprostenol infusion was continued for 2 months after the patient was discharged home; last PAP was measured 32/10 mmHg. CONCLUSIONS: Severe intraoperative pulmonary hypertension during liver transplantation was successfully treated using the combination of IV epoprostenol infusion and NO inhalation in medium and high concentrations.

Administration, Inhalation↗

Effects of bispectral index monitoring on recovery from surgical anesthesia in 1,580 inpatients from an academic medical center.

BACKGROUND: The purpose of this study was to determine whether monitoring Bispectral Index (BIS) would affect recovery parameters in patients undergoing inpatient surgery. METHODS: Anesthesia providers (n = 69) were randomly assigned to one of two groups, a BIS or non-BIS control group. A randomized crossover design was used, with reassignment at monthly intervals for 7 months. Duration of time in the postanesthesia care unit, time from the end of surgery to leaving the operating room, and incidence of delayed recovery (> 50 min in recovery) were compared in patients treated intraoperatively with or without BIS monitoring. Data were analyzed by analysis of variance, unpaired t test, or chi-square test as appropriate. RESULTS: One thousand five hundred eighty patients in an academic medical center were studied. The mean BIS in the monitored group was 47. No differences were found in recovery parameters between the BIS-monitored group and the control group when comparisons were made using all subjects or when data were analyzed within anesthetic subgroups stratified by anesthetic agent or duration of anesthesia. There were some small reductions in the intraoperative concentration of sevoflurane (but not isoflurane). CONCLUSIONS: The use of BIS monitoring for inpatients undergoing a wide variety of surgical procedures in an academic medical center had some minor effects on intraoperative anesthetic use but had no impact on recovery parameters.

Academic Medical Centers↗

Injuries and liability related to central vascular catheters: a closed claims analysis.

BACKGROUND: To assess changing patterns of injury and liability associated with central venous or pulmonary artery catheters, the authors analyzed closed malpractice claims for central catheter injuries in the American Society of Anesthesiologists Closed Claims database. METHODS: All claims for which a central catheter (i.e., central venous or pulmonary artery catheter) was the primary damaging event for the injury were compared with the rest of the claims in the database. Central catheter complications were defined as being related to vascular access or catheter use or maintenance. Statistical analysis was performed using the chi-square test, Fisher exact test, or Z test (proportions) and the Kolmogorov-Smirnov test (payments). RESULTS: The database included 110 claims for injuries related to central catheters (1.7% of 6,449 claims). Claims for central catheter injuries had a higher severity of injury, with an increased proportion of death (47%) compared with other claims in the database (29%, P < 0.01). The most common complications were wire/catheter embolus (n = 20), cardiac tamponade (n = 16), carotid artery puncture/cannulation (n =16), hemothorax (n =15), and pneumothorax (n =14). Cardiac tamponade, hemothorax, and pulmonary artery rupture had a higher proportion of death (P < 0.05) compared with the rest of the central catheter injures. The proportion of claims for vascular access injury increased (47% to 84%) and use/maintenance injury decreased (53% to 16%) in 1994-1999 compared with 1978-1983 (P < 0.05). CONCLUSIONS: Claims related to central catheters had a high severity of patient injury. The most common complications causing injury were wire/catheter embolus, cardiac tamponade, carotid artery puncture/cannulation, hemothorax, and pneumothorax.

Catheterization, Central Venous↗

Methadone for the induction of anesthesia: plasma histamine concentration, arterial blood pressure, and heart rate.

UNLABELLED: Despite the widespread use of methadone for the treatment of acute and chronic pain, the hemodynamic effects of methadone administered by IV bolus have not been studied. We compared the hemodynamic effects of an IV bolus of methadone 20 mg with those of fentanyl 10 microg/kg for the induction of anesthesia in combination with etomidate 0.3 mg/kg. Forty-three patients undergoing major surgery were randomized to one of the two treatments in a double-blinded fashion. Plasma concentrations of histamine were measured before and 2 min after opioid administration. Heart rate and arterial blood pressure were measured via an arterial line just before opioid administration, etomidate administration, and tracheal intubation; during intubation; and 1 min after intubation. There were no significant differences in mean heart rate between the methadone and fentanyl groups at any time point. Systolic and diastolic blood pressures were significantly lower (P < 0.05) in the fentanyl group just before intubation, during intubation, and 1 min after intubation. Mean plasma concentrations of histamine before and after the administration of methadone or fentanyl were 1.54 ng/mL (SD, 0.65 ng/mL) and 1.57 ng/mL (SD, 1.37 ng/mL) or 1.00 ng/mL (SD, 0.58 ng/mL) and 1.04 ng/mL (SD, 0.47 ng/mL), respectively. Despite the lack of a significant change in mean plasma concentrations of histamine, substantial increases in plasma histamine occurred in 2 of 23 patients who received methadone. There were no obvious hemodynamic effects associated with histamine concentrations up to 6.2 ng/mL. Methadone appears to have the potential for producing histamine release. Although methadone administration did not produce hemodynamic instability in this study, the possible hemodynamic side effects of histamine release should be considered when IV boluses of methadone are given. IMPLICATIONS: The same dose of IV methadone (20 mg) that is effective for postoperative pain is also suitable for the induction of anesthesia in combination with etomidate. The plasma histamine concentration was notably increased in two patients, without obvious hemodynamic sequelae. Therefore, methadone appears to have the potential for producing histamine release.

Adult↗

Nocturnal arterial oxygen desaturation and episodic airway obstruction after ambulatory surgery.

Some patients experience disordered breathing during sleep and arterial oxygen desaturation after major inpatient surgery. We performed this study to determine whether similar events occur after ambulatory surgery. Forty-five ambulatory surgery patients received an unrestricted anesthetic. Continuous unattended nocturnal recordings of breathing pattern and oxygen saturation were made in the patients' homes before surgery and during the first and second postoperative nights. Nine patients had a respiratory disturbance index >10 and/or >1% of recording time with oxygen saturation <90% on at least one study night. These nine patients had a significantly older median age and a significantly larger median body mass index. Their median respiratory disturbance index and median percentage of time with oxygen saturation <90% were significantly higher on the first postoperative night than on the preoperative night.

Adult↗

The incidence of awareness during anesthesia: a multicenter United States study.

Awareness with recall after general anesthesia is an infrequent, but well described, phenomenon that may result in posttraumatic stress disorder. There are no recent data on the incidence of this complication in the United States. We, therefore, undertook a prospective study to determine the incidence of awareness with recall during general anesthesia in the United States. This is a prospective, nonrandomized descriptive cohort study that was conducted at seven academic medical centers in the United States. Patients scheduled for surgery under general anesthesia were interviewed in the postoperative recovery room and at least a week after anesthesia and surgery by using a structured interview. Data from 19,575 patients are presented. A total of 25 awareness cases were identified (0.13% incidence). These occurred at a rate of 1-2 cases per 1000 patients at each site. Awareness was associated with increased ASA physical status (odds ratio, 2.41; 95% confidence interval, 1.04-5.60 for ASA status III-V compared with ASA status I-II). Age and sex did not influence the incidence of awareness. There were 46 additional cases (0.24%) of possible awareness and 1183 cases (6.04%) of possible intraoperative dreaming. The incidence of awareness during general anesthesia with recall in the United States is comparable to that described in other countries. Assuming that approximately 20 million anesthetics are administered in the United States annually, we can expect approximately 26,000 cases to occur each year.

Adult↗

Biphasic shocks compared with monophasic damped sine wave shocks for direct ventricular defibrillation during open heart surgery.

BACKGROUND: Biphasic waveform shocks are more effective than monophasic shocks for transchest ventricular defibrillation, atrial cardioversion, and defibrillation with implantable defibrillators but have not been studied for open chest, intraoperative defibrillation. This prospective, blinded, randomized clinical study compares biphasic and monophasic shock effectiveness and establishes intraoperative energy dose-response curves. METHODS: Patients undergoing cardiothoracic surgery with bypass cardioplegia were randomly assigned to the monophasic or biphasic shock group. Ventricular fibrillation occurring after aortic clamp removal was treated with escalating energies of 2, 5, 7, 10, and 20 J until defibrillation occurred. If ventricular fibrillation persisted, a 20-J crossover shock of the other waveform was used. RESULTS: Cumulative defibrillation success at 5 J, the primary end point of the study, was higher in the biphasic group than in the monophasic group (25 of 50 vs. 9 of 41 defibrillated; P = 0.011). In addition, the biphasic group required lower threshold energy (6.8 vs. 11.0 J; P = 0.003), less cumulative energy (12.6 vs. 23.4 J; P = 0.002), and fewer shocks (2.5 vs. 3.5; P = 0.002). Crossover-shock effectiveness did not differ between groups. Dose-response curves show biphasic shocks to have higher cumulative success rates at all energies tested. CONCLUSIONS: Biphasic shocks are substantially more effective than monophasic shocks for direct defibrillation. The dose-response curve guides selection of first-shock energy for traditional step-up protocols. Starting at 5 J optimizes for lowest threshold and cumulative energy, whereas 10 or 20 J optimizes for more rapid defibrillation and fewer shocks.

Adult↗

Complications of invasive monitoring.

Invasive monitoring in anesthesiology is relatively safe. Arterial catheterization in particular has an extremely low rate of serious complications. Radial, brachial, and femoral artery catheterization sites appear to have similar and low complication rates. CVP and PA catheters are more dangerous and entail potentially fatal complications. The most troublesome complication with CVP catheters is perforation of the heart or cava, which should be avoidable under most circumstances if care is taken to position the catheter properly, outside the heart. Chest radiography should be used to specifically ascertain that the catheter is not in a dangerous location. The most troublesome complication with PA catheters is perforation of the pulmonary artery. This is probably a sporadic problem, and it is not necessarily avoidable by adherence to particular techniques. It should be assumed that hemoptysis in a patient with a PA catheter is caused by perforation of the pulmonary artery until proven otherwise, and it should be treated aggressively.

Catheterization↗