PubMed Health⌕ Search

Biomedical subjects

T Azami

Publications and source records attributed to T Azami.

26 records · Page 2Linked to original sources

Acute left atrial thrombus causing cardiogenic shock following mitral valve replacement: report of a case.

We report herein the rare case of a 53-year-old woman who developed cardiogenic shock due to an acute left atrial thrombus following replacement of the mitral valve. A definitive diagnosis was not able to be made using precordial echocardiography because of the broad, flat shape of the thrombus; however, transesophageal echocardiography imaged the thrombus in detail. The patient was initially stabilized by percutaneous cardiopulmonary support after which a thrombectomy was successfully performed.

Echocardiography, Transesophageal↗

[Simultaneous operations for both the repair of the aortic arch aneurysm and repeated CABG].

A 73-year-old female complaining of left thoracic pain was referred to our hospital. In 1988, she had the first CABG of the left circumflex coronary artery (CX) and right coronary artery. On admission in April 1994, chest X-ray and CT scan revealed a saccular aortic aneurysm, 5 x 5 cm in size, extending to the distal to the left subclavian artery. Coronary arteriography showed a patency of the CX graft, but 99% stenosis of the proximal left anterior descending branch (LAD) with delayed opacification. After the repeated median sternotomy, cardiac arrest was achieved with the aortic cross clamping and St. Thomas Hospital solution infusion. CABG to the LAD branch using a saphenous vein was accomplished. Following this, the replacement of the aortic aneurysmal lesion with a prosthetic graft was performed under the selective cerebral perfusion with deep hypothermia. Proximal anastomosis of the vein graft was completed during a rewarming period. The operation was performed without complications. Postoperative course was satisfactory except a few minor transient complications such as athelectasis of the left upper lobe and the intra-thoracic hematoma. After one month's hospitalization, she was discharged, and currently (six months postoperative) remains asymptomatic.

Aged↗

[A surgical case of aortic dissection Stanford type A caused by blunt chest trauma--a report of a successful case].

A case of successfully repaired traumatic aortic dissection was reported. A 66-year-old woman with a blunt chest trauma from the car accident was transferred to our hospital. The radiological examination revealed Stanford type A aortic dissection without aortic regurgitation. Because of disturbance of consciousness and respiratory failure due to the associated blunt lung injury, she was treated in the intensive care unit, and, after 1 month, a graft replacement of the ascending aorta by using deep hypothermia with retrograde cerebral perfusion was carried out. The postoperative course was uneventful. Blunt chest trauma is very rare to cause aortic dissection, and the operative indication should be determined with careful consideration of the associated organ injuries.

Aortic Dissection↗

[Clinical study of optimal bypass flow for temporary bypass with centrifugal pump in surgical treatment of aneurysm of the descending thoracic aorta].

Since 1987, 33 patients were operated on for aneurysm of the descending thoracic aorta using temporary bypass with a heparin-coated centrifugal pump and heparin-coated tubes at Kobe University Hospital. Sixteen patients had true aneurysms of the descending thoracic aorta, 7 had thoraco-abdominal aneurysms and 10 had aortic dissection (DeBakey's type III). Heat exchanger and oxygenator were not included in the bypass circuit in all cases. Perfusion time was from 42 to 205 minutes (average 90 minutes). Left heart bypass was established with 1 mg/kg of systemic heparinization in 5, 0.5 mg/kg in 5, and 0 mg/kg in 23 cases. There were no complications such as perioperative embolism, acidosis, or hypothermia. During aortic cross-clamping, the arterial pressure of the lower extremity was maintained over 70 mmHg, but there was no relationship between the distal perfusion pressure and bypass flow. The urine output during temporary bypass was significantly related to the distal perfusion flow by centrifugal pump (r = 0.455, p < 0.01). Seven out of 23 patients who were bypassed under 40 ml/kg/min of distal perfusion flow showed transient renal dysfunction postoperatively, and two developed postoperative renal failure, while the other patients bypassed over 40 ml/kg/min of pump flow stayed in the normal range of the renal function, where there were statistically differences (p < 0.05). Postoperative paresis occurred in 2 patients who were also perfused under 40 ml/kg/min of bypass flow. Therefore, it is concluded that temporary bypass with centrifugal pump is a safe and well acceptable circulatory support in the surgical treatment of aneurysm of the descending aorta.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Surgical treatment for aneurysms of the descending aorta using temporary perfusion by a centrifugal pump: clinical analysis of 33 cases.

Since 1987, 33 patients have undergone surgery at Kobe University Hospital for aneurysm of the descending aorta using left heart bypass with a heparin-coated centrifugal pump and heparin-coated tubes. Sixteen patients had true aneurysms of the descending thoracic aorta, 7 had thoracoabdominal aneurysms, and 10 had aortic dissection (DeBakey's Type III). Heat exchangers and oxygenators were not included in the bypass circuit in any of the cases. Perfusion time was from 42 to 205 min (average 90 min). Left heart bypass was established with 1 mg/kg of systemic heparinization in 5 cases, 0.5 mg/kg in 5 cases, and 0 mg/kg in 23 cases. There were no complications such as perioperative embolism, acidosis, or hypothermia. During aortic cross-clamping, the arterial pressure of the lower extremity was maintained above 70 mm Hg, but there was no relationship between the distal perfusion pressure and bypass flow. The urine output during left heart bypass was related to the distal perfusion flow by centrifugal pump. Of 23 patients who underwent bypass with less than 40 ml/kg/min of distal perfusion flow, 7 showed transient renal dysfunction postoperatively, and 1 developed postoperative renal failure. The other patients who were bypassed with over 40 ml/kg/min of pump flow stayed in the normal range of renal function. Postoperative paresis occurred in 2 patients, who were also perfused with less than 40 ml/kg/min of bypass flow. It could be concluded that left heart bypass by centrifugal pump is safe and acceptable as a circulatory support in the surgical treatment of aneurysm of the descending aorta.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Beneficial circulatory support by left heart bypass with a centrifugal (BioMedicus) pump for aneurysms of the descending thoracic aorta.

A comparative study between left heart bypass with a centrifugal (BioMedicus) pump and with a temporary external shunt was performed to assess the efficacy of distal organ perfusion in the surgical treatment of 31 patients with aneurysm of the descending thoracic aorta. Eighteen patients were supported with a centrifugal pump, and the remaining 13 were supported by temporary shunt with either a Gott shunt or a Dacron graft. Heparinless bypass with a centrifugal pump provided a significant decrease of intraoperative blood loss and blood transfusion by the combined application of Cell-Saver. The pressure difference between upper and lower extremities decreased (p < 0.05) in the centrifugal pump group even with aortic cross-clamping, and the urine output increased during operation. Among 13 patients supported with the temporary shunt, 3 had postoperative renal failure, and 2 died of it. All patients with a centrifugal pump survived without any complications. It could be concluded that the left heart bypass with a centrifugal (BioMedicus) pump was safe and was favorable for support of the distal circulation during aortic cross-clamping and to prevent ischemic complications such as renal failure and spinal cord injury.

Adult↗

[A case of left atrial ball thrombus].

A 76-year-old man admitted to one hospital complaining of transient left hemiparesis. Because of arrhythmia, he was examined by an echocardiogram and found to have an oval free-floating thrombus in his left atrium concomitant with mitral stenosis. He was transferred to our hospital for emergency surgery. On operation, a 3 x 4 cm ball thrombus was removed and diseased mitral valve was replaced with a SJM prosthetic valve. His postoperative course was relatively uneventful. Though left atrial ball thrombus is rarely found among the patients with mitral valve disease, when left atrial ball thrombus is found, immediate surgical intervention is recommended to avoid sudden death.

Heart Atria↗