Evaluation of a new percutaneous stainless steel Greenfield filter.

PURPOSE: To evaluate a new percutaneous Greenfield filter with an alternating hook design and over-the-wire delivery system. MATERIALS AND METHODS: The alternating hook stainless steel Greenfield filter was evaluated in a prospective clinical trial between March 10, 1994, and January 27, 1995. Filters were placed in 75 patients in nine clinical centers and follow-up with radiographs and ultrasound scans was carried out at 30 days. RESULTS: Clinical trial results revealed successful placement in all patients. There were four cases of filter limb asymmetry (5.3%) without clinical sequelae, with one incidence of failure to span the cava. No significant migration was found. There were no clinically suspected pulmonary emboli, but one instance of probable caval penetration (1.7%) did occur. Caval occlusion was documented in three patients (5%). CONCLUSION: The percutaneous stainless steel Greenfield filter provides ease of insertion and improved deployment while maintaining the high standards of efficacy and safety associated with the standard and titanium Greenfield filters.

Adult↗

IVC filter tilt and asymmetry: comparison of the over-the-wire stainless-steel and titanium Greenfield IVC filters.

PURPOSE: A comparison of tilting, caval coverage, asymmetry, and insertion problems with the over-the-wire stainless-steel and titanium versions of the Greenfield filter. MATERIALS AND METHODS: The study compared 104 stainless-steel and 141 titanium Greenfield inferior vena cava (IVC) filter insertions. The angle the sheath and deployed filter made relative to the cava, as well as filter strut distribution, were determined from spot films. The proportionate caval coverage was computed from the cavogram (anteroposterior projection). Mean filter tilts, subgrouped by insertion site, and caval coverage were compared with the Student t test, whereas strut patterns were analyzed with a contingency table. RESULTS: The filter caval and sheath caval angles correlated. The filter caval angles varied with insertion site, but were lowest with a right jugular approach. Caval coverage was identical with both designs. The stainless-steel version resulted in a more uniform distribution of struts in comparison with the titanium version. The incidence of insertion problems was not significantly different between the filter types. CONCLUSIONS: While IVC filter tilting was not improved with the newer design, the pattern of struts was more uniformly symmetric with the stainless-steel device. The right jugular insertion site was associated with the lowest filter caval angles and the most symmetric pattern of struts.

Chi-Square Distribution↗

Importance of Doppler analysis of transmitted atrial waveforms prior to placement of central venous access catheters.

PURPOSE: To assess the sensitivity of Doppler flow analysis of the axillary and internal jugular veins to screen for clinically occult thoracic central veno-occlusive disease and predict successful placement of central access catheters. MATERIALS AND METHODS: Sixty-seven patients underwent both duplex sonographic evaluation of the axillary and internal jugular veins and contrast venography prior to placement of a central venous catheter. Duplex evaluation included visual evidence of veno-occlusive disease as well as the presence or absence of normal transmitted polyphasic atrial waves and respiratory variation of flow. Diagnostically adequate venograms were available for comparison with the duplex sonograms in 168 access routes (access site plus downstream conduit veins). The contrast venograms and sonograms were compared by using retrospective blinded interpretation. Outcome of attempted catheter placement was tabulated. RESULTS: Directed sonographic imaging of the axillary and internal jugular vein allowed detection of access route veno-occlusive disease with a sensitivity of only 33.3%. Alternatively, when Doppler flow analysis found atrial waveforms that were not polyphasic, central conduit occlusive disease was detected with a sensitivity of 79.6%. Monophasic atrial waveforms were associated with a 25% failure rate of catheterization due to central vein occlusive disease, whereas polyphasic atrial waveforms were correlated with a 100% success rate for catheter placement. CONCLUSION: In asymptomatic patients, sonographic imaging alone misses most instances of central veno-occlusive disease. However, Doppler flow analysis of transmitted atrial waveforms substantially improved the sensitivity. A normal polyphasic atrial waveform virtually excludes the possibility of a more central venous occlusion or stenosis greater than 80% and ensures an adequate route for central venous catheterization.