PubMed Health⌕ Search

Biomedical subjects

T Beugeling

Publications and source records attributed to T Beugeling.

At least 37 records · Page 2Linked to original sources

In vitro leucocyte adhesion to modified polyurethane surfaces. I. Effect of ionizable functional groups.

To study the effect of ionizable functional groups on the adhesion of leucocytes to surfaces, both poly(ethyleneimine) and poly(acrylic acid) were immobilized on polyurethane films, resulting in the introduction of amine and carboxylic acid groups, respectively. This was confirmed by contact angle measurements and XPS analysis. In vitro adhesion of granulocytes and lymphocytes on untreated and modified surfaces was compared. The number of adherent cells on modified surfaces as a function of time was significantly higher than on untreated surfaces. This effect was most pronounced for the adhesion of lymphocytes to surfaces modified with amine groups. In this case, the number of adherent cells after 1 h of exposure was three times higher than on untreated surfaces. A moderate enhancement of leucocyte adhesion was observed in the case of surfaces modified with carboxylic acid groups. There is evidence that these groups were not ionized under the experimental conditions used. The modification procedures described may be used to improve polyurethane filters for the removal of leucocytes from blood.

Cell Adhesion↗

Improved adhesion and proliferation of human endothelial cells on polyethylene precoated with monoclonal antibodies directed against cell membrane antigens and extracellular matrix proteins.

Endothelial cell seeding may improve the patency of synthetic vascular grafts provided that platelet reactivity of nonendothelialized sites is not increased. We have investigated if surface-adsorbed monoclonal antibodies directed against endothelial cell membrane proteins and against extracellular matrix proteins promote the adhesion and proliferation of cultured human endothelial cells, without causing platelet deposition at non-endothelialized sites. Adhesion of endothelial cells onto polyethylene coated with monoclonal antibodies directed against endothelial cell-specific membrane antigens, integrin receptors and glycoprotein CD31 was equal to or higher than adhesion onto fibronectin-coated polyethylene. Endothelial cells did not proliferate on these surface-adsorbed antibodies. However, pre-coating of polyethylene with mixtures of endothelial cell-specific monoclonal antibodies and monoclonal antibodies directed against fibronectin or von Willebrand factor, resulted in relatively high adhesion and optimal proliferation. Platelet reactivity of the polyethylene surface was found to significantly increase after adsorption of fibronectin, endothelial cell-specific monoclonal antibody or its Fc fragments. In contrast, adsorption of F(ab')2 fragments of endothelial cell-specific monoclonal antibody did not promote platelet deposition. Therefore, it is concluded that coating of vascular graft materials with mixtures of F(ab')2 fragments of monoclonal antibodies specifically directed against endothelial cells and against extracellular matrix proteins may be an effective way to both promote the growth of seeded endothelial cells and limit platelet-graft interaction.

Adsorption↗

Asymmetric membrane filters for the removal of leukocytes from blood.

As part of a study on the mechanisms of leukocyte filtration, the influence of pore size distribution on filter efficiency was investigated. Conventional leukocyte filters are not suitable for model studies, as these filters are composed of tightly packed synthetic fibers, with a poorly defined porous structure. Therefore, open cellular polyurethane membranes with pore size distributions varying from approximately 15 to 65 microns were prepared. Filtration experiments with stacked packages of these membranes showed that leukocytes are best removed (greater than 99%) by filters with a pore size distribution of 11-19 microns. These pore sizes approach the size of leukocytes (6-12 microns). However, due to fast clogging, blood flow through these filters is rapidly reduced, which results in a low filter capacity. With an asymmetric membrane filter, in which the pore size decreases from about 65 to 15 microns in the direction of blood flow, both moderate removal of leukocytes (greater than 80%) and maintenance of flow (approximately 0.2 mL/s) are obtained. This results in efficient leukocyte removal. From cell analysis of both filtrate and filter, it is concluded that adhesion rather than sieving is the major filtration mechanism. Thus, further optimization of the filter may be achieved by surface modification.

Cell Separation↗

Adhesion of endothelial cells and adsorption of serum proteins on gas plasma-treated polytetrafluoroethylene.

From in vitro experiments it is known that human endothelial cells show poor adhesion to hydrophobic polymers. The hydrophobicity of vascular prostheses manufactured from Teflon or Dacron may be the reason why endothelialization of these grafts does not occur after implantation in humans. We modified films of polytetrafluoroethylene (Teflon) by nitrogen plasma and oxygen plasma treatments to make the surfaces more hydrophilic. Depending on the plasma exposure time, modified polytetrafluoroethylene surfaces showed water-contact angles of 15-58 degrees, versus 96 degrees for unmodified polytetrafluoroethylene. ESCA measurements revealed incorporation of both nitrogen- and oxygen-containing groups into the polytetrafluoroethylene surfaces, dependent on the plasma composition and exposure time. The thickness of the modified surface layer was approximately 1 nm. The adhesion of cultured human endothelial cells from 20% human serum-containing culture medium to modified polytetrafluoroethylene surfaces with contact angles of 20-45 degrees led to the formation of a monolayer of cells, which was similar to the one formed on tissue culture polystyrene, the reference surface. This was not the case when endothelial cells were seeded upon unmodified polytetrafluoroethylene. Surface-modified expanded polytetrafluoroethylene prosthesis material (GORE TEX soft tissue) also showed adhesion of endothelial cells comparable to cell adhesion to the reference surface. The amounts of serum proteins, including fibronectin, adsorbed from serum-containing medium to modified polytetrafluoroethylene surfaces were larger than those adsorbed to unmodified polytetrafluoroethylene. Moreover, the modified surfaces probably allow the exchange of adsorbed serum proteins with cellular fibronectin.

Adsorption↗

Protein adsorption from plasma onto poly(n-alkyl methacrylate) surfaces.

Protein adsorption of human serum albumin (HSA), human fibrinogen (Fg), human immunoglobulin G (IgG), high density lipoprotein (HDL) and high molecular weight kininogen (HMWK) from plasma onto poly (n-alkyl methacrylate) (PAMA) surfaces was measured using a semi-quantitative enzyme-immunoassay. Adsorption was investigated for PAMA(n = 1) (n is the number of C-atoms in the n-alkyl side chain), PAMA(n = 8) and PAMA(n = 18). PAMA(n = 1) has a relatively hydrophilic surface as compared to the more hydrophobic PAMA(n = 8) surface. Both polymers have surface chains which do not reorient after contact with water. The PAMA(n = 18) surface is relatively hydrophobic but in this case polymer surface chains and segments are able to reorient after contact with water. Protein adsorption was measured both as a function of time and as a function of the plasma dilution. If adsorption from plasma was measured as a function of time no exchange of proteins could be observed. The amount of adsorbed protein was always larger in the case of the hydrophobic PAMA(n = 8) as compared to PAMAS(n = 1 and 18), probably due to hydrophobic interactions between the proteins and the PAMA(n = 8) surface. At high plasma concentration relatively large amounts of HDL adsorb onto PAMA(n = 8), indicating that this lipoprotein preferentially adsorbs onto this surface.

Adsorption↗

Large-scale purification of factor VIII by affinity chromatography: optimization of process parameters.

The optimization of a new process for the extraction of human coagulation factor VIII (FVIII) from plasma with the tailor-made affinity matrix dimethylamino-propylcarbamylpentyl-Sepharose CL-4B (C3-C5 matrix) is described. First, plasma is applied to DEAE-Sephadex A-50 anion exchanger in order to separate a number of proteins, including coagulation factors II, IX and X (prothrombin complex), from FVIII. Subsequently, the unbound fraction of the ion exchanger, containing FVIII, is contacted with the C3-C5 affinity matrix. Optimization of the FVIII affinity chromatographic procedure is accomplished in terms of the ligand density of the matrix, adsorption mode (batch-wise versus column-wise adsorption and matrix to plasma ratio), and conditions of pH and conductivity to be applied on washing and desorption. In scale-up experiments, by processing 20 l of plasma, the recovery (340 U VIII:C/kg plasma) and the specific activity (s.a.) (1.2 U VIII:C/mg protein) are better than those obtained by cryoprecipitation (recovery 300 U VIII:C/kg plasma, s.a. 0.3 U VIII:C/mg protein). The newly developed process using the specially designed C3-C5 affinity matrix has potential application in the process-scale purification of FVIII.

Buffers↗

Detection of surface-adsorbed (lipo)proteins by means of a two-step enzyme-immunoassay: a study on the Vroman effect.

In view of reports on the involvement of high-molecular-weight (HMW) kininogen and high-density lipoprotein (HDL) in the Vroman effect, we studied the adsorption of fibrinogen, HMW kininogen, HDL and several other proteins from pooled human plasma and congenitally HMW kininogen-deficient plasma onto glass and low-density polyethylene, both as a function of the plasma concentration and the contact time. Mixtures of purified (lipo)proteins were also included in the study. Protein adsorption was determined by means of a two-step enzyme-immunoassay. Our results support the hypothesis that HMW kininogen is involved in the displacement of fibrinogen, which is almost instantly adsorbed from normal plasma onto glass. On hydrophobic polymers like polyethylene, the low amounts of adsorbed fibrinogen and HMW kininogen from plasma and concentrated plasma solutions may be due to a preferential adsorption of HDL.

Adsorption↗

The effect of vascular cell seeding on platelet deposition in an in vitro capillary perfusion model.

In view of the reported beneficial effects of cell seeding on the performance of synthetic vascular grafts, we determined the deposition of 111Indium-labelled human platelets in polyethylene capillary tubes covered with human endothelial cells (HEC) or smooth muscle cells (SMC) using an in vitro perfusion model. Platelet deposition decreased with increasing vascular cell coverage and was virtually absent when the number of adherent vascular cells of both types exceeded 50,000/cm2. Platelet deposition increased with increasing shear rate (300-900 s-1) only when surface coverage was less than 50,000 vascular cells/cm2. Deposition of Ca2+-ionophore A 23187-activated platelets in capillary tubes completely covered with SMC was significantly higher compared to capillaries covered with a similar number of HEC. When HEC-lined capillaries were treated with aspirin, only the deposition of activated platelets increased slightly, but significantly. This platelet reactivity was more evident when the endothelial lining was not confluent. These results demonstrate that, although seeding of HEC and SMC may both prevent the deposition of non-activated platelets to surfaces, non-aspirin-treated confluent HEC linings offer the best protection against deposition of activated platelets.

Aspirin↗

Adhesion and spreading of cultured endothelial cells on modified and unmodified poly (ethylene terephthalate): a morphological study.

The in vitro adhesion and spreading of human endothelial cells (HEC) on hydrophobic poly(ethylene terephthalate) (PETP) and moderately wettable tissue culture poly(ethylene terephthalate) (TCPETP) were studied with light microscopy and electron microscopy. Numbers of HEC adhering on TCPETP were always higher than those found on PETP. When cells were seeded in the presence of serum, extensive cell spreading on both PETP and TCPETP was observed after the first 30 min. Thereafter, spread cells appeared to withdraw from the PETP surface, resulting in irregularly shaped cells. Complete cell spreading occurred on TCPETP. Complete cell spreading also occurred on PETP and TCPETP when HEC had first been seeded from phosphate buffer solution and serum was supplied after 30 min. Furthermore, HEC spread on both PETP and TCPETP when the surfaces were precoated with protein(s), which promotes cell adhesion. However, when plasma was used for the coating, spread cells did not proliferate in a monolayer pattern. This study shows that TCPETP is, in general, a better surface for adhesion and proliferation of HEC than is PETP, suggesting that vascular prostheses with a TCPETP-like surface will perform better in vivo than prostheses made of PETP.

Blood↗

Surface modification of copolyether-urethane catheters with poly(ethylene oxide).

Pellethane 2363 80A catheters were modified with poly(ethylene oxide) in order to improve their blood compatibility. Contact angle measurements showed that Pellethane 2363 80A surfaces had increased wettability after this modification. The results of in vitro blood compatibility tests showed that surface modification with poly(ethylene oxide) resulted in a five-fold reduction of platelet deposition. Activation of coagulation was not affected.

Biocompatible Materials↗

Deposition of endothelial fibronectin on polymeric surfaces.

Cellular fibronectin is deposited on tissue culture polystyrene during the adhesion and spreading of cultured human endothelial cells (HEC). Following the seeding of HEC upon this polymer, larger amounts of fibronectin are deposited as both cell density and incubation time increase. Our results indicate that the ability to deposit cellular fibronectin onto a polymeric surface is a condition for the spreading and proliferation of HEC.

Adsorption↗

Platelet deposition in a capillary perfusion model: quantitative and morphological aspects.

The capillary perfusion model according to Cazenave and co-workers was characterized by investigating the effects of protein precoating, perfusion time and shear rate on platelet deposition using 111Indium labelling of human platelets and scanning electron microscopy (SEM). Compared with uncoated polyethylene, platelet deposition was increased after precoating with purified human von Willebrand factor, fibrinogen or fibronectin, and decreased by preadsorbed immunoglobulin G, albumin or whole plasma. Platelet aggregates were observed on immunoglobulin G-coated polyethylene, whereas all other surfaces showed single adherent platelets. Complete platelet spreading was only observed after precoating with fibronectin. The quantitative data concerning platelet deposition were evaluated by using the convective-diffusion theory. Our results indicate the applicability of this perfusion model for the in vitro testing of biomaterials.

Adsorption↗

The influence of protein adsorption on interactions of cultured human endothelial cells with polymers.

A systematic study of the effects of polymer surface properties on the interaction with human endothelial cells (HEC) may lead to the development of small-diameter vascular grafts. HEC, suspended in culture medium containing 20% serum adhered and spread onto moderately wettable polymers such as TCPS (tissue culture polystyrene). Reduced or no adhesion of HEC was observed upon the hydrophobic polymers PETP (polyethyleneterephthalate, Dacron) and FEP (fluoroethylenepropylene copolymer, Teflon). Polymers precoated with the proteins albumin (Alb), high density lipoprotein (HDL), and immunoglobulin G (IgG) inhibited the adhesion of HEC, whereas fibronectin (Fn) coatings promoted cell adhesion. Endothelialization of PETP and FEP only occurred after precoating of these materials with Fn. The adsorption of Fn, Alb, HDL, and IgG from solutions of different serum concentrations onto TCPS, PETP, and FEP was related to the adhesion of HEC. Serum Fn only adsorbed onto TCPS, with the maximum at 0.1% serum concentration. Maximal cell adhesion onto TCPS was also observed after pretreatment with a solution containing 0.1% serum. The cell adhesion inhibiting proteins Alb and HDL preferentially adsorbed at higher serum concentrations. Desorption of these proteins and exchange for, e.g., cellular Fn may result in cell spreading and proliferation of HEC upon TCPS.

Adsorption↗

Adsorption of fibronectin derived from serum and from human endothelial cells onto tissue culture polystyrene.

Human endothelial cells (HEC) suspended in a culture medium containing 20% human serum (CMS) adhere and spread on(to) moderately wettable polymers, such as tissue culture polystyrene (TCPS). We have previously shown that serum derived-fibronectin, which is a cell adhesion promoting protein, has a high affinity for TCPS, but that the amount of fibronectin which adsorbed from CMS was relatively small. In this study we investigated whether fibronectin derived from HEC contributes to the adhesion and spreading of the cells on(to) TCPS. Therefore, HEC were seeded in the presence of fibronectin-depleted CMS. The amount of fibronectin detected on TCPS increased with both cell seeding density and incubation time. Although initial HEC adhesion is delayed on TCPS which has been precoated with albumin (Alb), high density lipoprotein (HDL) or immunoglobulin G (IgG), maximal numbers of adhering and spreading HEC were found on these surfaces 6 h after seeding of HEC. Fibronectin was detected on these surfaces, but an exchange of preadsorbed Alb, HDL, or IgG for fibronectin could not be demonstrated. We conclude that HEC deposit fibronectin onto TCPS, irrespective of the presence of a preadsorbed layer of proteins which delay cell adhesion.

Adsorption↗

Adhesion of cultured human endothelial cells onto methacrylate polymers with varying surface wettability and charge.

The adhesion of human endothelial cells (HEC) onto a series of well-characterized methacrylate polymer surfaces with varying wettabilities and surface charges was studied either in serum-containing (CMS) or in serum-free (CM) culture medium. HEC adhesion in CMS onto (co)polymers of hydroxyethyl methacrylate (HEMA) and methyl methacrylate (MMA) was found to be optimal on the moderately wettable copolymer (mol ratio 25 HEMA/75 MMA). Positively-charged copolymers of HEMA or MMA with trimethylaminoethyl methacrylate-HCl salt (TMAEMA-Cl), both with mol ratios of 85/15 and a negatively-charged copolymer of MMA with methacrylic acid (MAA), mol ratio 85/15, showed high numbers of adhering HEC. In CM, HEC adhered onto the three charged copolymers mentioned above, but neither onto the copolymer of HEMA and MAA (mol ratio 85/15) nor onto the HEMA/MMA co- and homopolymers. Complete cell spreading in CM was only observed on the positively-charged copolymers.

Acrylates↗

Interaction of cultured human endothelial cells with polymeric surfaces of different wettabilities.

The in vitro interaction of human endothelial cells (HEC) and polymers with different wettabilities in culture medium containing serum was investigated. Optimal adhesion of HEC generally occurred onto moderately wettable polymers. Within a series of cellulose type of polymers the cell adhesion increased with increasing contact angle of the polymer surfaces. Proliferation of HEC occurred when adhesion was followed by progressive flattening of the cells. Our results suggest that moderately wettable polymers exhibit a serum and/or cellular protein adsorption pattern that is favourable for growth of HEC.

Cell Adhesion↗

Preferential adsorption of high density lipoprotein from blood plasma onto biomaterial surfaces.

In the present study a two step enzyme immuno assay (EIA) was used for the investigation of the adsorption of proteins and lipoproteins from solutions and from blood plasma onto polymer surfaces. It was found that only a small adsorption of the major blood proteins occurred from plasma. Evidence is presented that the reason for this adsorption behaviour is a preferential adsorption of high density lipoprotein (HDL).

Adsorption↗

Anticoagulant activity of a synthetic heparinoid in relation to molecular weight and N-sulfate content.

Addition of chlorosulfonyl isocyanate to C==C bonds in cis-1,4-polyisoprene and reaction of the adduct with NaOH resulted in the formation of a water-soluble polyelectrolyte with N-sulfate and carboxylate groups. The polyelectrolyte showed anticoagulant activity and it was found, just as with heparin, that the activity was related to molecular weight and N-sulfate content.

Blood Coagulation↗