PubMed Health⌕ Search

Biomedical subjects

T Birmingham

Publications and source records attributed to T Birmingham.

3 recordsLinked to original sources

Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players.

STUDY DESIGN: Single group, test-retest. OBJECTIVES: To determine: (1) hip abduction and adduction torques during concentric and eccentric muscle actions, (2) medial and lateral one-leg hop distances, (3) the test-retest reliability of these measurements, and (4) the relationship between isokinetic measures of hip muscle strength and hop distances in elite ice hockey players. BACKGROUND: The skating motion used in ice hockey requires strong contractions of the hip and knee musculature. However, baseline scores for hip strength and hop distances, their test-retest reliability, and measures of the extent to which these tests are related for this population are not available. METHODS AND MEASURES: The dominant leg of 27 men (mean age 20 +/- 3 yrs) was tested on 2 occasions. Hip abduction and adduction movements were completed at 60 degrees.s(-1) angular velocity, with the subject lying on the non-test side and the test leg moving vertically in the subject's coronal plane. One-leg hops requiring jumping from and landing on the same leg without losing balance were completed in the medial and lateral directions. RESULTS: Hip adduction torques were significantly greater than abduction torques during both concentric and eccentric muscle actions, while no significant difference was observed between medial and lateral hop distances. Although hop test scores produced excellent ICCs (> 0.75) when determined using scores on 1 occasion, torques needed to be averaged over 2 test occasions to reach this level. Correlations between the strength and hop tests ranged from slight to low (r = -0.26 to 0.27) and were characterized by wide 95% confidence intervals (-0.54 to 0.61). CONCLUSIONS: Isokinetic tests of hip abduction and adduction did not provide a strong indication of performance during sideways hop tests. Although isokinetic tests can provide a measure of muscular strength under specific test conditions, they should not be relied upon as a primary indicator of functional abilities or readiness to return to activity.

Adult↗

Functional knee braces and dynamic performance: a review.

OBJECTIVE: The purpose of the present review was to examine current experimental research on the effectiveness of functional knee braces (FKBs) used by patients with anterior cruciate ligament injury during dynamic performance tests. DATA SOURCES: Twelve studies published in peer-reviewed journals and listed in the Excerpta Medica system were reviewed. STUDY SELECTION: All studies compared braced and unbraced tests performed by the same subjects, using tests characterized by weight bearing/axial loading. DATA EXTRACTION: Studies were reviewed independently by three investigators. DATA SYNTHESIS: Tests included one-leg hop, figure-of-eight run, stair climbing, walking, cutting, agility runs, straight running, and bicycle ergometry. Experimental situations were classified as follows: (a) maximal effort tests, which compared overall measures of performance such as the distance hopped and the time to run a specific distance; and (b) matched submaximal effort tests, which compared specific variables such as electromyography, range of motion, ground reaction forces, and energy costs. Bracing was found to be advantageous in three of the 16 maximal effort situations, disadvantageous in two, and of no measurable effect in 11. Six of the 10 matched effort situations reported differences in the criterion measurements when braced, while four reported no differences. CONCLUSIONS: If FKB prescription is to be based solely on empirical evidence of efficacy from performance tests, then further investigation is required to provide this evidence. Future research needs to examine the subjective and psychological aspects of FKB usage along with the results of objective performance tests.

Braces↗

Comparisons of weight-bearing and non-weight-bearing tests of knee proprioception performed by patients with patello-femoral pain syndrome and asymptomatic individuals.

OBJECTIVE: To compare non-weight-bearing (sitting) and weight-bearing (standing, with approximately 95% of body weight on the test leg) tests of knee proprioception performed by patients with patello-femoral pain syndrome (PFPS) and asymptomatic individuals. DESIGN: A repeated measures design, repeated on two occasions. SETTING: Athletic injuries clinic. PARTICIPANTS: Seven men and 17 women with PFPS, and age- and sex-matched asymptomatic individuals. INTERVENTIONS: With their eyes closed, subjects extended their knee in sitting, or flexed their knees in standing, attempting to replicate target angles (15 degrees, 30 degrees, 45 degrees, and 60 degrees knee flexion) measured using an electrogoniometer. MAIN OUTCOME MEASURE: Observed angle of knee flexion during joint angle replication tests. RESULTS: Test-retest reliability coefficients (0.17-0.79) and between-session measurement error (+/-2.0 degrees to +/-6.4 degrees) varied widely. There was a tendency for reliability coefficients to be greater and between-session measurement error to be lower, for PFPS subjects, and for sitting tests. No significant differences were observed between the scores of the PFPS and asymptomatic subjects, at any of the four target knee angles. CONCLUSIONS: Scores in sitting should not be compared with those in standing. Clinically, the low reliability coefficients, large between-session measurement error, and finding of no statistically significant difference between PFPS and asymptomatic subjects suggest that the diagnostic value of the proprioceptive tests used is questionable. Further research is required to develop more precise tests of knee proprioception and to determine if the present results are applicable to other pathologies.

Adult↗