PubMed Health⌕ Search

Biomedical subjects

T Bolognese-Milsztajn

Publications and source records attributed to T Bolognese-Milsztajn.

9 recordsLinked to original sources

Overview of active personal dosemeters for individual monitoring in the European Union.

In 2001, the European Radiation Dosimetry Group, EURADOS, started a working group on 'Harmonisation of Individual Monitoring in Europe and the Dissemination of Information on New Techniques in this Field'. Within this group, one of the projects consisted of analysing the status of active personal dosemeters (APDs) in Europe. This paper reviews the regulatory requirements for APDs in 15 EU member states and summarises the main characteristics of commercial and new developments in this field. In particular, it focuses on the comparison of APD performance and standard passive dosimetry systems. Based on this information, an evaluation is initiated to establish why several countries are reluctant to accept APDs for dose records.

Environmental Exposure↗

Evaluation of individual monitoring in mixed neutron/photon fields: mid-term results from the EVIDOS project.

EVIDOS is an EC sponsored project that aims at an evaluation and improvement of radiation protection dosimetry in mixed neutron/photon fields. This is performed through spectrometric and dosimetric investigations during different measurement campaigns in representative workplaces of the nuclear industry. The performance of routine and, in particular, novel personal dosemeters and survey instruments is tested in selected workplace fields. Reference values for the dose equivalent quantities, H(*)(10) and H(p)(10) and the effective dose E, are determined using different spectrometers that provide the energy distribution of the neutron fluence and using newly developed devices that determine the energy and directional distribution of the neutron fluence. The EVIDOS project has passed the mid-term, and three measurement campaigns have been performed. This paper will give an overview and some new results from the third campaign that was held in Mol (Belgium), around the research reactor VENUS and in the MOX producing plant of Belgonucléaire.

Equipment Design↗

Aspects of harmonisation of individual monitoring for external radiation in Europe: conclusions of a EURADOS action.

Following the publication of the EU Council Directive 96/29, EURADOS coordinated two working groups (WGs) for promoting the process of harmonisation on individual monitoring of occupationally exposed persons in Europe. An overview of the major findings of the second WG is presented. Information on the technical and quality standards and on the accreditation and approval procedures has been compiled. The catalogue of dosimetric services has been updated and extended. An overview of national regulations and standards for protection from radon and other natural sources in workplaces has been made, attempting to combine the results from individual monitoring for external, internal and workplace monitoring. A first status description of the active personal dosemeters, including legislative and technical information, and their implementation has been made. The importance of practical factors on the uncertainty in the dose measurement has been estimated. Even if a big progress has been made towards harmonisation, there is still work to be done.

Europe↗

Numerical and experimental results of the operational neutron dosemeter 'Saphydose-N'.

Since 1993, the Institute for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricité de France (EDF), a R&D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics.

Algorithms↗

Individual neutron monitoring in workplaces with mixed neutron/photon radiation.

EVIDOS ('evaluation of individual dosimetry in mixed neutron and photon radiation fields') is an European Commission (EC)-sponsored project that aims at a significant improvement of radiation protection dosimetry in mixed neutron/photon fields via spectrometric and dosimetric investigations in representative workplaces of the nuclear industry. In particular, new spectrometry methods are developed that provide the energy and direction distribution of the neutron fluence from which the reference dosimetric quantities are derived and compared to the readings of dosemeters. The final results of the project will be a comprehensive set of spectrometric and dosimetric data for the workplaces and an analysis of the performance of dosemeters, including novel electronic dosemeters. This paper gives an overview of the project and focuses on the results from measurements performed in calibration fields with broad energy distributions (simulated workplace fields) and on the first results from workplaces in the nuclear industry, inside a boiling water reactor and around a spent fuel transport cask.

Artifacts↗

Active personal dosemeters for individual monitoring and other new developments.

In this paper, we will present a first (but not complete) status description of active personal dosemeters (APDs) and their implementation in European countries. In modern radiation protection practices, APDs are becoming absolutely necessary operational tools for satisfying the ALARA principle. Despite their success, they are relatively new for individual monitoring of workers. Regulation, legal requirements and calibration procedures are different in European member states. A catalogue of commercially available and prototype devices is presented. Improvement on devices and in implementation of calibration method are expected in the forthcoming years. End-user feedback experience and requirements are reported.

Body Burden↗

The first operational dosemeter for neutrons which complies with IEC standard 1323.

Individual neutron dosimetry represents one of the current difficulties in the field of radiological protection of workers. Since March 1999, the regulatory requirements in France for active (i.e. operational) dosimetry have been those of ICRP Publication 60, applicable from May 2000, necessitating the introduction of a new generation of neutron dosemeters. Over the last few years, the Institute for Nuclear Safety and Protection has been studying an individual electronic dosemeter for neutrons based on a semiconducting detector, capable of meeting the specifications laid down by a neutron dosimetry work group, including members from all the main players in the French nuclear industry. In 1998, the IPSN began transferring technology to the Saphymo company which, by the end of 2001, will be marketing Saphydose-n, the first individual dosemeter for neutrons which complies with IEC Standard 1323. This dosemeter is of compact design and can assess the individual dose equivalent Hp(10) in mixed neutron and gamma radiation fields. It wil be usable in any nuclear facility without prior knowledge of the average neutron spectrum or of the neutron-gamma ratio. It will be possible to connect the Saphydose-n dosemeter to any of the existing gamma deserter terminals to read the dose data and recharge the batteries.

Air Pollution, Radioactive↗

Study of the photon radiation performance of electronic personal dosemeters.

Following the specifications and test methods given by international standards IEC-61526 and ISO 4037, the dosimetry department of the IPSN studied the photon radiation performance of seven recent electronic personal dosemeters: The personal dosimetric performance of each piece of equipment was tested with X and gamma radiation between 12 keV and 1.25 MeV.

Air Pollution, Radioactive↗

An active personal neutron dosemeter based on microdosimetric principles: CIME.

Over the last few years IPSN has been developing a small, tissue equivalent proportional counter (TEPC) with multielement geometry for personal radiation protection monitoring. This paper presents the last prototype, which is insensitive to microphony, and the experimental results. Numerical modelling results using CERN codes are partly presented and allow an understanding of the nuclear and electrostatic physics involved in a TEPC.

Consumer Product Safety↗