PubMed Health⌕ Search

Biomedical subjects

T Burkhard

Publications and source records attributed to T Burkhard.

2 recordsLinked to original sources

Synthesis and cardiotonic activity of novel biimidazoles.

A series of substituted 2,2'-bi-1H-imidazoles and related analogues was synthesized and evaluated for inotropic activity. Structure-activity relationship studies based on a nonclassical bioisosteric approach indicated the necessity of a cyano group on one of the imidazole rings to obtain the desired pharmacological profile. 4(5)-Cyano-2,2'-bi-1H-imidazole (15a) was the most potent inotropic agent in the series. It produced a 25% increase in left ventricular dP/dt at 0.16 mg/kg iv (ED25% = 0.16 mg/kg) and increased left ventricular contractile force 60% at 1 mg/kg iv in anesthetized dogs. Compound 15a is a good inhibitor of type IV cyclic nucleotide phosphodiesterase isolated from dog heart having a potency similar to that of amrinone. Neither 5'-cyano-2,4'-bi-1H-imidazole (44) nor 4-cyano-2,4'-bi-1H-imidazole (48) demonstrated inotropic activity. In addition, the two possible 1,1'-dimethylcyano-2,2'-bi-1H-imidazoles (24 and 25) were inactive, indicating that an acidic NH as well as a cyano group are essential for inotropic activity.

2',3'-Cyclic-Nucleotide Phosphodiesterases↗

Optimized veno-venous bypass with the affinity pump.

Veno-venous bypass (VVBP) is increasingly used to avoid acute venous hypertension and low cardiac output after clamping the vena cava. Air embolism upon accidental decannulation of the inflow line and endothelial damage due to suction of the blood collecting cannula to the vessel wall are known complications specific to the currently used roller and centrifugal pumps, because they generate negative pressure at the inflow site of the pump. The Affinity pump has a unique chamber design with an occlusive segment, that collapses in low filling states preventing negative pressure at the inflow site of the pump chamber. This device was tested for VVBP in three pigs (each weighing 52.3 +/- 5.1 kg) with hepatic vascular exclusion. Blood was pumped from the femoral and portal veins to the external jugular vein and perfusion was maintained for 6 hours. The hemodynamic state of the animals was assessed by recording heart rate; systolic, mean arterial, and diastolic pressure; as well as central venous pressure. Mean pump flow during the experiment was 1,629.3 +/- 372.2 ml/min. After clamping, the inflow line of the pump mean arterial pressure significantly decreased (from 69.5 +/- 4.4 to 43.1 +/- 3.5 mm Hg), and mean pressure in the femoral vein increased significantly (from 16.1 +/- 2.6 to 26.8 +/- 5.9 mm Hg), whereas the mean pressure in the internal jugular vein did not significantly change (from 6.0 +/- 1.7 to 5.0 +/- 2.1 mm Hg). There was no suction by the blood collecting cannula on the vessel wall, and neither bubbles nor air emboli were detected and no operator intervention was needed. In conclusion, the Affinity pump eliminates device related complications due to negative pressure generated at the inlet, and guarantees stable hemodynamics. Its application is simple and safe and minimal operator intervention is needed, making the Affinity pump particularly suited for veno-venous bypass.

Animals↗