PubMed Health⌕ Search

Biomedical subjects

T Conte

Publications and source records attributed to T Conte.

15 recordsLinked to original sources

Dynamic evaluation of a fixed bed anaerobic digestion process in response to organic overloads and toxicant shock loads.

This paper details a dynamic evaluation of a 1 m3 fixed bed anaerobic digestion reactor in response to organic overloads and toxicant shock loads. Raw industrial wine distillery wastewater was used as a reference substrate and several disturbances were applied to the process: (i) organic overloads with and without pH regulation in the feeding line, (ii) adding of ammonia in the input wastewater. The purpose of this study was to assess, using on-line instrumentation, the robustness of a fixed bed anaerobic digester. Anaerobic digestion processes have the reputation of being difficult to operate and prone to process instability due to external disturbances and the objective of this study was to demonstrate the possibility of such a reactor configuration for industrial use.

Automation↗

Automatic control of volatile fatty acids in anaerobic digestion using a fuzzy logic based approach.

A control law based on fuzzy logic was developed and validated for an anaerobic wastewater treatment process. The controlled variable was the concentration of volatile fatty acids (VFA) in the reactor and the manipulated variable was the input flow rate. In order to use it as the input of the fuzzy sets, the controlled variable was treated using an algorithm of interpolation, extrapolation and filtering. The treatment of VFA values attempted to anticipate the behaviour of the variable and to avoid the inherent delay of the response, associated to the time constant of the system. Furthermore, the controlled variable derivative was used as a second input of the fuzzy sets to increase or decrease the speed of the control action. The control law was applied to a 0.948 m3 fixed-bed anaerobic reactor treating raw and diluted (1:2) industrial distillery vinasses. The validation was performed establishing different transient states between different set points in the range of 0.8 and 1.8 g VFA/l and different concentrations of the influent. The control law proved to be reliable supplying an adequate control action in terms of amplitude and velocity to achieve the desired set point for different types of perturbation and control purposes.

Automation↗

Model based prediction of the clogging of an anaerobic fixed bed reactor.

This paper presents the use of nonlinear constrained optimization techniques in order to detect and evaluate the degree of clogging in an anaerobic fixed bed reactor. First, experimental results show that the validity of a mass balance model can degrade over the time. Using the available model of the process and nonlinear constrained optimization tools, it is established that these changes can be due to the decrease of the liquid volume into the reactor while the mean values of biomass concentrations increase, leading to the clogging of the reactor. These theoretical results are confirmed experimentally in evaluating the hydraulic retention time of the reactor using a tracer.

Anaerobiosis↗

Evaluation of a four year experience with a fully instrumented anaerobic digestion process.

For several years, a 1 m3 fixed bed anaerobic digestion process has been operated for the treatment of distillery vinasses. This reactor has been fully instrumented with the following variables available on-line: pH, temperature, liquid and gas flow rates, gas composition (i.e., CH4, CO2 and H2), concentration of bicarbonate, chemical oxygen demand, total organic carbon, volatile fatty acids and partial and total alkalinity, these last four variables being measured twice by different techniques (i.e., using a TOC analyzer, a titrimetric sensor and an infrared spectrometer). The purpose of this paper is to compare the respective benefits of advanced instrumentation for the monitoring of wastewater treatment processes in general, and for anaerobic digestion in particular. It will also provide some statistical analysis of the time required to operate a fully instrumented wastewater treatment process. It is indeed well admitted in the literature that instrumentation is usually the main limitation step for using closed-loop control. However, it is our opinion that, in the near future, this situation will change. This point is discussed based on our four years practical experience.

Anaerobiosis↗

On-line measurements of COD, TOC, VFA, total and partial alkalinity in anaerobic digestion processes using infra-red ectrometry.

This paper describes the use of a Fourier Transform Infra-Red (FT-IR) spectrometer as an on-line sensor to measure Chemical Oxygen Demand (COD), Total Organic Carbon (TOC), Volatile Fatty Acids (VFA), and Partial and Total Alkalinity (PA and TA) in anaerobic digestion processes for the treatment of industrial wastewaters. Comparison with manual off-line analysis and with an on-line industrial TOC analyser and an on-line titrimetric sensor (for the measurements of VFA, TA and PA) are provided to demonstrate the interest of spectral analysis in the mid infra-red domain for the monitoring of anaerobic digestion processes. In order to further illustrate the advantages of using such a technique, on-line measurements recorded during an accident of the pH regulation in the input (pH in the reactor went above 11 and biomass activity stopped) are shown. They demonstrate that, if carefully performed, the calibration can be extended outside its range while being still compatible with requirements of wastewater treatment processes.

Bacteria, Anaerobic↗

Sensitivity to pH, product inhibition, and inhibition by NAD+ of 1,3-propanediol dehydrogenase purified from Enterobacter agglomerans CNCM 1210.

Because of its key role in the metabolism of glycerol during fermentation, 1,3-propanediol dehydrogenase (EC 1.1.1.202) of Enterobacter agglomerans CNCM 1210 was purified to homogeneity and studied with respect to its sensitivity to pH and to nucleotide and 1,3-propanediol concentrations. Enzyme activity was optimal at pH 7.8. The enzyme was competitively inhibited by NAD+ (Ki of 0.29 mM), and 1,3-propanediol exerted a strong inhibitory effect according to a mixed-type inhibition with a Ki of 13.7 mM and an a-factor of 9.0. It is proposed that these dehydrogenase properties be extended to the dehydrogenases of Citrobacter freundii and Klebsiella pneumoniae, which exhibited numerous similar physical properties.

Alcohol Dehydrogenase↗

Experimental evaluation of the effects of pravastatin on electrophysiological parameters of rat skeletal muscle.

The effects of daily chronic treatment for 6 months with pravastatin was evaluated on the performance of the skeletal muscle system of different rat groups. At all doses (0.1 mg/kg-20 mg/kg) the righting reflex and the electromyographic signals observed in vivo did not show any abnormality. At the end of the treatment the Extensor digitorum longus muscles were dissected from treated and control rats and their passive and active electrical parameters were analyzed in vitro by standard microelectrodes technique. Pravastatin did not modify the chloride conductance nor the excitability characteristics of the fibers. Chronic treatment with pravastatin does not produce any alteration of skeletal muscle function.

Animals↗

[Action of indoprofen on atrio-ventricular conduction. Preliminary note].

The purpose of the present study was to evaluate the possible electrophysiological effects of Indoprophene, a new non steroidal analgesic anti-inflammatory agent, which might be employed in the treatment of chest-pain from myocardial ischemia. Ten patient, who were undergoing a electrophysiological study for diagnostic purposes, were given 400 mg of indoprophene by intravenous rapid bolus. The A-V conduction times were recorded in basic condition and 30 minutes after administration of the drug. The data we collected show that Indoprophene does not influences either normal or prolonged A-V conduction times. We conclude that the drug, as it has a good effect on pain and lacks haemodynamic consequences and effects on conduction and excitability, is recommendable for the treatment of chest-pain from myocardial ischemia.

Aged↗