[Swiss pacemaker statistics of the years 1989, 1990 and 1991].

In the annual pacemaker survey covering practically all pacemakers implanted in Switzerland (there have been 50 implanting hospitals in the last three years) the number of first implants increased from 242 per million population in 1989 to 252 in 1991. Clinical indications, ECG-indications and etiology have undergone no significant changes in the last three years. Within the pacing-systems used however there was a marked increase in rate responsive single chamber pacemakers from 25% in 1989 to 34% in 1991. The percentage of double chamber pacemakers however increased gradually from 14% in 1989 to 21% 1991. At the present time there are some 10,000 patients with a cardiac pacemaker in this country.

Adolescent↗

[Swiss pacemaker statistics for 1987/1988].

In the annual pacemaker survey, covering practically all pacemakers implanted in Switzerland (implanted in 43 hospitals in 1987 and in 46 in 1988), the number of first implants in 1987 was 226 and in 1988 238 per million population. Clinical indications, ECG indications and etiology have undergone no significant changes in the last 3 years. Within the pacing systems used, however, there has been a relative increase in physiological pacemakers to 10% and in rate adaptive pacemakers to 19%. At the present time there are some 10,000 patients with a cardiac pacemaker in this country.

Adolescent↗

[Heart pacemaker].

The function of the different systems of cardiac pacemakers and their programmability are explained. The follow-up of the pacemaker patient is described, differentiated following the possibilities available to the general practitioner in his office and the specialized pacemaker clinic. Some dysfunctions encountered from time to time are described as practical examples.

Arrhythmias, Cardiac↗

[Swiss statistics on the use of cardiac pacemakers in 1986].

The 1986 annual pacemaker survey covers the data from all centers implanting cardiac pacemakers in Switzerland. The number of centres has increased from 34 to 36 while the number of first implants remains unchanged with 226 per million population. Clinical indications, ECG indications and etiology have undergone no significant changes in the last 3 years. Within the pacing system used, however, 13% of VVI pacemakers were now rate responsive, whereas the percentage of physiological pacemakers remained unchanged at 7%.

Humans↗

[Physical performance with rate-responsive pacemakers].

The effects of the new rate-responsive pacemaker Medtronic Activitrax on maximal exercise heart rate and physical work capacity were studied acutely and after two weeks in 10 patients. Compared to the VVI-mode, heart rate increased in activity mode during exercise from 102.1 +/- 29.0 to 115.8 +/- 13.5/min (p less than 0.05). Similarly, physical work capacity increased from 343 +/- 260 to 528 +/- 354 watts X min (p less than 0.02). This effect persisted over 2 weeks. Thus, using rate-responsive pacing a significant improvement in working capacity could be shown in patients with inadequate exercise heart rate.

Aged↗

[Swiss pacemaker statistics, 1985].

In the annual pacemaker survey covering all 34 centres implanting cardiac pacemakers in Switzerland the data have been collected in more detail in the last two years and are presented more extensively. The number of first implants (1146, or 225 per million population) has remained constant with slight variation over the last 3 years. Dysfunction of the sinus node as an indication decreased to 31%. The use of programmable pacemakers further increased, leaving only 6% non-programmable. Physiological pacemaker-systems were used slightly less frequently but not in the larger pacemaker centers. The rate of intervention for lead problems remained unchanged at 1.1% of the total pacemaker population.

Humans↗

[Reevaluation of pacemaker-induced reentry tachycardias: incidence, mechanisms and therapy].

To reassess incidence, mechanisms and therapeutic possibilities in the treatment of pacemaker-induced reentry tachycardias (RT) in patients with the second generation of DDD-pacemakers, 35 consecutive patients were studied prospectively by measuring VA conduction at implant and searching for RT clinically and by repeat 24-hour ECG monitoring. Reprogramming to the VVI mode because of atrial flutter and to the AAI mode because of lead displacement was necessary in 2 and 1 of the patients respectively. RT were detected in 7/32 patients (22%), 4 of whom were symptomatic. The triggering mechanism of RT was premature ventricular contraction in 4 patients, premature atrial contractions in 1, loss of atrial sensing in 1, and remained unclear in 1. Unlike the 30% of patients of an earlier consecutive series with first generation of physiologic PM who had RT and required permanent reprogramming to VVI stimulation in 10% of cases, RT was abolished in all patients maintaining physiologic pacing by prolonging the atrial refractory period, shortening the av delay, adjusting atrial output or atrial sensing, or by antiarrhythmic therapy.

Aged↗

[Swiss pacemaker statistics for 1984].

In a study of Swiss pacemaker statistics for 1984, all 34 centres implanting cardiac pacemakers in Switzerland were covered. The number of first implants slightly decreased (218 per million population compared with 230 in 1983). There are some 7500 pacemaker patients in Switzerland, most of the pacemakers being multiprogrammable or programmable. The percentage of physiological systems increased to 10% and in some centres up to 35%. Reintervention for lead problems was necessary in 1.2% of the total pacemaker population.

Humans↗

[Swiss pacemaker statistics in 1983].

The data on 98% of pacemakers implanted in 1983 in Switzerland were analyzed and compared with previous years. The number of first implantations slightly increased to 240 per million population per year (1982: 216). 80% of pacemakers used were multiprogrammable, and 7.7% were physiological pacemakers. Counting only the centers implanting physiological pacemakers, the number is 14.5%. Complications demanding reinterventions decreased slightly. This applied especially to complications related to implantation techniques.

Aged↗

[Swiss pacemaker statistics of the year 1982].

The data of 96% of pacemaker implantations in Switzerland is analyzed and compared with previous years. The numbers of first implantations slightly increased to 216 per million population per year. The percentage breakdown of the various indications remain unchanged. Two thirds of the pacemakers implanted were multiprogrammable. Implantation of physiologic pacemakers has increased to 8.8% in recent years. Complications requiring reintervention decreased despite the increase in first implantations.

Adolescent↗

Prevalence and significance of reversible radionuclide ischemic perfusion defects in symptomatic aortic valve disease patients with or without concomitant coronary disease.

To determine the prevalence and significance of exercise-induced localized perfusion defects in symptomatic patients with aortic valve disease, thallium-201 rest and exercise studies were performed in a consecutive series of 29 such patients prior to left heart catheterization with coronary arteriography. Eight patients had repeat studies after aortic valve replacement. Twelve of 17 patients with predominant aortic regurgitation (AR) had distinct LV apical defects during exercise despite normal coronary arteries, while 10 of 12 patients with aortic valve disease and associated coronary artery disease (CAD) had localized perfusion defects in LV areas other than the apex. In patients with AR, reversible apical perfusion defects can occur without CAD; these apical defects are probably a reflection of severe LV volume overload in AR. LV perfusion defects in areas other than the apex are specific for CAD in aortic valve disease, and concomitant CAD may not provoke regional LV perfusion deficits in aortic stenosis patients with severe LV hypertrophy.

Adult↗

[Can ischemia-induced wall motion abnormalities of the left ventricle be predicted by non-invasive thallium-201 scintigraphy? Comparison with the ventriculography test].

To assess the relation between stress-induced perfusion defects and wall motion abnormalities (WMA), 20 patients were studied by thallium-201 (201Tl) scintigraphy and cineventriculography at rest and during exercise. Of 100 analyzed segments, 63 were normal while 13 showed constant (scar) and 24 reversible (ischemia) perfusion defects. At peak exercise, 85% of the scar and 80% of the ischemic segments corresponded to abnormally contracting wall segments. There was a marked correlation between the extent of ischemia and the degree of WMA. The increase in abnormal scintigraphic and angiographic segments from rest to exercise was parallel by a significant deterioration in left ventricular function. It is concluded that (1) ischemic perfusion defects detected by 201Tl scintigraphy correlate well with exercise induced wall motion abnormalities, and (2) the localization, extent and degree of WMA can be predicted by non-invasive 201Tl scintigraphy.

Coronary Disease↗

'Variant' angina: evidence for small vessel coronary artery spasm?

A unique case of 'variant' angina pectoris has been observed in a patient with normal coronary arteries and typical chest pain appearing spontaneously at rest, and repeatedly provoked by ergonovine maleate (0.1 mg iv) associated with large transmural perfusion defects on 201Tl-imaging (after ergonovine) and a marked increase in T wave voltage despite no demonstrable spasm of a major coronary artery after the same doses of ergonovine. While saline solution could not provoke chest pain and treatment with a beta-blocking agent increased the frequency of ischemic attacks, a calcium antagonist therapy reduced and eventually eliminated the attacks. Thus, this case provides evidence for yet another aspect of a 'variant' form of angina pectoris: small vessel coronary artery spasm.

Adult↗