PubMed HealthSearch

Biomedical subjects

T D Chavis

Publications and source records attributed to T D Chavis.

6 recordsLinked to original sources

Initial experience with collagen-filled Guglielmi detachable coils for endovascular treatment of experimental aneurysms.

PURPOSE: To evaluate the effectiveness of Guglielmi detachable coils (GDCs) filled with collagen threads in the permanent treatment of experimental aneurysms. METHODS: Seventeen side-wall aneurysms were surgically constructed in the canine common carotid artery; six were treated with conventional GDCs and 11 with collagen-filled GDCs. One aneurysms was removed at 1 week, the others were studied by digital subtraction angiography for a period of 8 to 12 weeks. Longitudinal sections of all aneurysms were examined by light microscopy. RESULTS: Angiograms obtained throughout the follow-up period showed no significant difference between aneurysms treated with conventional GDCs and those treated with collagen-filled GDCs. Light microscopy revealed a dense meshwork of newly formed collagen and fibroblasts near the collagen-filled GDCs, whereas a loose cellular meshwork surrounded the conventional GDCs at 8 and 12 weeks after treatment. CONCLUSION: Collagen threads within GDCs do not noticeably improve angiographic treatment of experimental aneurysms; however, these threads did induce local proliferation of fibroblasts and production of collagen within the aneurysmal cavities.

Aneurysm

FasTRACKER-18.

Explore the source record for details and available documents.

Catheterization, Peripheral

Delayed recanalization of a cerebral arteriovenous malformation following angiographic obliteration with polyvinyl alcohol embolization.

BACKGROUND: The efficacy of embolization of cerebral arteriovenous malformations (AVMs) is presently being evaluated. Embolization of single pedicle AVMs may produce complete angiographic obliteration and has been suggested as the sole therapy for treating these lesions. METHODS: A 17-year-old female presented with a left intraventricular and intraparenchymal cerebral hemorrhage resulting from a 1 cm left posterior choroidal AVM. She subsequently underwent polyvinyl alcohol (PVA) embolization of the AVM with complete angiographic obliteration. RESULTS: At 9 months follow-up, no evidence of recanalization of the AVM nidus was seen. Two years later, recanalization of the nidus was seen; and the patient received radiosurgical treatment. The natural history of previously embolized AVMs is reviewed and the mechanisms for recanalization are discussed. CONCLUSION: We recommend that patients with angiographic obliteration of AVMs receive further treatment, preferably resection, or be followed with serial angiography.

Adolescent

Balloon test occlusion of the internal carotid artery with hypotensive challenge.

PURPOSE: To evaluate the usefulness of provocative testing with hypotensive challenge during balloon test occlusion of the internal carotid artery before carotid sacrifice and to correlate tolerance of balloon test occlusion with clinical outcome after carotid artery sacrifice. METHODS: Forty-seven consecutive cases of balloon test occlusions performed at our institution during the past 4 years were retrospectively reviewed. Occlusion was performed under normotensive conditions with distal perfusion of heparinized saline for 20 minutes, or until a deficit was perceived. If 20 minutes of normotension was tolerated, hypotension was induced to two thirds of mean arterial pressure for 20 minutes, or until a deficit was perceived. RESULTS: Of 47 patients, 4 (9%) had deficits at normotension. Of the remaining 43 patients, 9 (21%) had deficits at hypotension. One patient with a positive hypotensive test occlusion underwent carotid artery sacrifice after extracranial-intracranial bypass without sequelae. In one of the 19 patients who clinically tolerated test occlusion with hypotension and had carotid sacrifice (surgical ligation of the intracranial carotid artery), a mild embolic stroke developed, probably from the giant carotid wall aneurysm. This patient fully recovered; MR imaging showed mild changes consistent with emboli distal to the aneurysm. Symptomatic complications were noted in 2 (4%) patients, and asymptomatic arterial dissections were noted in 3 (6%) patients. CONCLUSION: Balloon test occlusion with hypotensive challenge is safe, economical, and greatly increases the sensitivity of balloon test occlusion. The predictive value of a negative test is high. However, to determine the test's specificity compared with quantitative imaging, controlled trials will be necessary.

Adult

Endovascular management of giant intracranial aneurysms.

The role of endovascular therapy for the treatment of giant aneurysms is presently being defined. Results derived from the endovascular treatment of giant aneurysms must be compared to the effectiveness and safety of operative treatment and the natural history of the disease. Most reports on the results of endovascular aneurysm treatment are of patients who have failed operative intervention or in whom operative intervention was not attempted because of their poor medical condition or other factors. Thus, the results of these techniques are from a high-risk subgroup. In a recent series of 19 giant aneurysms treated by a variety of techniques, including coils, balloons, and rapidly solidifying polymers, one death resulted after aneurysm rupture during the procedure (86). However, the major cause of mortality was cardiopulmonary complications within the first 2 weeks after the procedure. At present, it may be appropriate to reserve endovascular techniques for patients with no other reasonable therapeutic option. As experience with these techniques is gained, a comparison must be undertaken in a series of patients clinically equivalent to those in surgical series. Presently, the consensus is that endovascular therapy for giant aneurysms is efficacious for parent-vessel occlusion after balloon test occlusion to assess tolerance to sacrifice. Endosaccular occlusion is most effective if the aneurysm contains little thrombus, as determined by the size of the aneurysm seen on CT or MRI (87), as compared to the angiographic image. Small-necked aneurysms are particularly suited to coil occlusion if the aneurysm can be tightly packed. In wide-necked aneurysms, coil occlusion is possible, although the risk of parent-vessel occlusion is high. We often perform balloon test occlusion of the vessel before placing coils in wide-necked aneurysms. Failure of endovascular therapy after complete angiographic obliteration is based on recanalization or regrowth, resulting from device migration or remodeling at the junction of the device with the inflow tract and aneurysm wall, or by migration of the device into thrombus. The effect of aneurysm remnants after balloon or coil occlusion will be determined by long-term follow-up, as emphasized by Fox et al. (20, 63). Whenever there is an aneurysm remnant, some risk of subsequent hemorrhage exists (66). Further device refinement will enhance the safety and effectiveness of the endovascular treatment of giant aneurysms. The use of combined endovascular and conventional surgical techniques may be an increasingly important option in the treatment of giant aneurysms. Endosaccular packing of an aneurysm with occlusive material may not provide the ability to completely exclude the aneurysm from the circulation, and thus, will not necessarily prevent the process of regrowth. A further limitation of the currently implemented endovascular treatment of aneurysms is that fluoroscopy does not provide detailed information of aneurysm remnants due to the superimposition of occlusive materials, which may necessitate the development of new real-time imaging modalities for interventional procedure, such as intravascular ultrasound and ultrafast-sequence MRI.

Angioplasty

Retrieval of a Guglielmi detachable coil after unraveling and fracture: case report and experimental results.

Unraveling and fracture of electrolytically detachable coils (Guglielmi detachable coils) may occur during treatment of intracerebral aneurysms. Retrieval of the detached coil is difficult using existing snare technology, and the intraluminal coil may cause parent vessel thrombosis or distal embolization. We report a case of unraveling and fracture of a Guglielmi detachable coil that was successfully retrieved using a dual guidewire technique. The technique was evaluated in an in vitro model using 10 coils of varying sizes and diameters, and allowed successful coil retrieval in all trials.

Aged