PubMed HealthSearch

Biomedical subjects

T Demos

Publications and source records attributed to T Demos.

9 recordsLinked to original sources

Renal computed tomography with 3-dimensional angiography and simultaneous measurement of plasma contrast clearance reduce the invasiveness and cost of evaluating living renal donor candidates.

Renal computed tomography (CT), 3-dimensional CT angiography (3D-CTA), and simultaneous measurement of glomerular filtration rate (GFR) by x-ray fluorescence determination of plasma contrast clearance (PCC) are alternatives to intravenous urography (IVU), renal arteriography (RA), and 24-hr urine creatinine clearance (CrCl) for evaluation of renal structure and function in living renal donor (LRD) candidates. To determine if CT, 3D-CTA, and PCC provide data comparable to IVU, RA, and CrCl, both methods were used to evaluate 23 LRD candidates. Costs were also compared. Conventional RA identified 19 accessory arteries and one case of medial fibroplasia. Each of these anomalous vessels was recognized on 3D-CTA. Venous anatomy was more clearly delineated on 3D-CTA than the venous phase of conventional RA. CT demonstrated 3 benign cysts and a single, small intraparenchymal calcification in 3 renal units. GFRs measured by PCC and CrCl were 91 +/- 4 and 132 +/- 7 ml/min/1.73m2, respectively (r = 0.64, P < 0.05). Total cost for CT/3D-CTA/PCC was 46% less than that of IVU/RA/CrCl and 40% less than RA/CrCl. CT/3D-CTA/PCC provided reliable structural and functional data at substantially less cost, discomfort, and inconvenience to the living renal donor candidate. As such, CT/3D-CTA/PCC is superior to conventional methods for evaluation of the living renal donor candidate.

Adult

Intravenous contrast bolus in computed tomography investigation of mass lesion.

Using bolus intravenous contrast (25-75 Renografin 60) and 5-second scanning capability, better definition of vascular anatomy as well as the vascular nature of mass lesions in the chest and abdomen could be demonstrated. The immediate higher concentration of iodine in vessels and organs following initial bolus, improves visualization of these structures dramatically when compared to drip-infusion technique. A description of the technique and examples are shown.

Abdominal Neoplasms

Symptomatic inverted Meckel's diverticulum. Case report.

The radiographic diagnosis of Meckel's diverticulum in an asymptomatic individual is extremely difficult. Complications of the diverticulum may make preoperative diagnosis possible. A persistent, elongated filling defect within the distal ileum in a patient with chronic blood loss and symptoms of partial obstruction is most likely to be due to an inverted Meckel's diverticulum.

Barium Sulfate

The viewbox.

Explore the source record for details and available documents.

Adult