PubMed Health⌕ Search

Biomedical subjects

T E Mollnes

Publications and source records attributed to T E Mollnes.

At least 55 records · Page 3Linked to original sources

In vitro evaluation of new surface coatings for extracorporeal circulation.

Cardiopulmonary bypass (CPB) exposes blood to large, foreign surfaces. This exposure may activate the cellular and humoral inflammatory systems, resulting in inflammatory reactions and organ dysfunction. Coating the inner surfaces of the bypass circuit may help alleviate these side-effects. The objective of this study was to determine the influence of two new surface treatments on blood cell and complement activation. Oxygenator and tubing sets coated with synthetic polymers (n = 7) or heparin (n = 7) were compared to uncoated sets (n = 7) in an in vitro model of CPB. The circuits were run at 4 l/min and recirculated for 120 min. The inflammatory response was assessed at regular intervals by platelet counts, and activation of complement, leucocytes and platelets. We found that the median platelet counts decreased from 127 to 122 x 10(9)/l (not significant, NS) in the synthetic polymer sets, from 96 to 88 x 10(9)/l (NS) in the heparin-coated sets, and from 93 to 54 x 10(9)/l (p < 0.01) in the uncoated sets after 2 h of recirculation. There were significant differences in platelet counts between the coated sets and the uncoated set at end of experiments (p < 0.05). Beta-thromboglobulin (BTG) concentrations increased in the synthetic polymer sets from 166 to 352 ng/ml (p < 0.01), in the heparin coated sets from 336 to 1168 ng/ml (p < 0.01), and in the uncoated sets from 301 to 3149 ng/ml (p < 0.01) after 2 h of recirculation. The differences in BTG at termination of the experiments were significant among all three sets (p < 0.05). Myeloperoxidase (MPO) concentrations in the synthetic polymer sets increased from 63 to 86 micrograms/l (p < 0.01), in the heparin-coated sets from 90 to 208 micrograms/l (p < 0.01), and in the uncoated sets from 122 to 513 micrograms/l (p < 0.01) after 2 h of recirculation. The differences in MPO at termination of the experiments were significant among all three groups (p < 0.01). There were no significant differences at termination of the experiments among the three sets regarding complement activation as measured by C3 activation products and the terminal complement complex. We conclude that in the current in vitro model of a CPB circuit, the synthetic polymer coating and the heparin coating caused significantly less platelet loss and granulocyte and platelet activation than the uncoated surface (p < 0.05). The synthetic polymer coating caused significantly less granulocyte and platelet activation than the heparin coating (p < 0.05). There was moderate complement activation within each group, but no significant differences among the three groups.

Complement Activation↗

Leucocyte filtration during cardiopulmonary reperfusion in coronary artery bypass surgery.

Postoperative organ dysfunction after cardiac operations has been related to the damaging effects of cardiopulmonary bypass (CPB). These complications are considered to be mediated partly by complement activation and subsequent activation of leucocytes due to the contact between blood and the large nonendothelial surfaces in the bypass circuit. Removal of leucocytes by filtration during the reperfusion period may potentially reduce the postoperative morbidity after CPB. Forty patients undergoing elective, primary coronary artery bypass grafting were randomized to initial identical bypass circuits until the aortic crossclamp was released. Then, the ordinary arterial line filter was closed and either a leucocyte depletion filter (n = 20), or a control filter (n = 20) was incorporated in the circuits during the reperfusion period of CPB. Blood samples were drawn at fixed intervals and analysed for white blood cell and platelet counts, plasma concentration of myeloperoxidase, C3-complement activation products, the terminal complement complex, and interleukins (IL)-6 and -8. The numbers of circulating white blood cells in the leucocyte-depleted group decreased during the reperfusion period from 5.5 (4.8-6.8) to 5.3 (4.4-6.2) x 10(9)/l, and increased in the control group from 6.5 (5.1-8.0) to 7.4 (5.7-9.0) x 10(9)/l. Two hours postoperatively the total white blood cell count in the leucocyte-depleted group was 14.7 (12.1-17.2) x 10(9)/l, and in the control group 17.6 (14.5-20.7) x 10(9)/l. The differences between the groups were statistical significant (p = 0.05). There were no statistically significant differences between the groups with regard to other test parameters or clinical data. We conclude that the use of leucocyte filters during the reperfusion period in elective coronary artery bypass surgery significantly reduced the number of circulating leucocytes, whereas no effects were seen for granulocyte activation measured as myeloperoxidase release, platelet counts, complement activation, or IL-6 and -8 release. The clinical benefit of leucocyte filters in routine or high risk patients remains to be demonstrated and is suggested to be dependent on both the efficacy and the biocompatibility of the filters.

Aged↗

Comparison of three oxygenator-coated and one total-circuit-coated extracorporeal devices.

The present study was designed to compare the biocompatibility of three cardiopulmonary bypass setups with different surface coatings, and to determine if coating of the whole circuit with one of the coatings was more beneficial than coating of the oxygenator only. Extracorporeal devices entirely coated with synthetic polymers (Avecor, n = 6) were compared to oxygenators coated with synthetic polymers (Avecor, n = 6), end-point, covalently attached heparin (CBAS, n = 6) or absorbed heparin (Duraflo 2, n = 6) in an in vitro model of a heart lung machine. The circuits were primed with fresh human whole blood and Ringer's acetate and recirculated at 4 l/min at 30 degrees C for 2 h. Test samples were obtained at regular intervals and analysed for myeloperoxidase (MPO), platelet counts, beta-thromboglobulin, heparin, prothrombin fragment 1+2, plasmin anti-plasmin complexes, and complement activation products. The mean MPO concentrations increased in the Avecor-coated oxygenator group (AV) from 247 at the start to 671 microg/l at the termination of the experiments, in the Avecor-coated total circuit group (AV-T) from 116 to 288 microg/l, in the Duraflo 2 coated oxygenator group (DU) from 160 to 332 microg/l, and in the CBAS-coated oxygenator (CA) group from 172 to 311 microg/l. The MPO concentrations increased significantly in all groups (p < 0.03). The increase in group A was significantly higher than in the other three groups (p = 0.007). The mean platelet counts decreased in the Avecor-coated total circuit group from 117 at start to 99 x 10(9)/l at termination of the experiments, in the Avecor-coated oxygenator group from 119 to 103 x 10(9)/l, in the Duraflo 2 group from 96 to 86 x 10(9)/l, and in the CBAS group from 132 to 123 x 10(9)/l. The platelet counts decreased significantly in all groups (p < 0.01), but the intergroup differences were not significant (p = 0.15). The mean beta-thromboglobulin concentrations increased in the Avecor-coated total circuit group from 193 at the start to 754 ng/ml at the termination of the experiments, in the Avecor-coated oxygenator group from 474 to 1654 ng/l, in the Duraflo 2 group from 496 to 1280 ng/l, and in the CBAS group from 418 to 747 ng/l. The beta-thromboglobulin increase was significant in each group (p < 0.01), but not between the groups (p = 0.49). The mean heparin concentrations in the Duraflo 2 group increased from 2460 at the start to 2897 IU/l at termination of the experiments, in the CBAS group from 2468 to 2518 IU/l. In the Avecor-coated oxygenator group heparin concentrations decreased from 2010 to 1968 IU/l, and in the Avecor-coated total circuit group from 2002 to 1927 IU/l. The differences in heparin concentrations were significant between the Duraflo 2 group and the other groups (p < 0.05). The mean prothrombin fragment 1+2 concentrations increased in the CBAS group from 0.4 at the start to 2.1 nmol/l at the end of the experiments, in the Avecor-coated oxygenator group from 0.4 to 0.6 nmol/l, in the Avecor-coated total circuit group from 0.3 to 0.4 nmol/l, and in the Duraflo 2 group from 1.2 to 1.3 nmol/l. The prothrombin fragment 1+2 increase was significant in all groups (p < 0.05), but there were no significant intergroup differences (p = 0.54). There were no significant differences at the termination of the experiments among the four groups regarding complement activation as measured by C3 activation products and the terminal complement complex. In the present in vitro model of a heart-lung machine, none of the three specific setups with different coatings was superior with regard to all test parameters. The CBAS group generated the highest levels of prothrombin fragment 1+2 formation, but least complement activation. The increasing plasma heparin concentrations in the Duraflo 2 group indicated more unstable heparin bonding. The Avecor-coated total circuit group were superior to the Avecor-coated oxygenator group regarding plasma concentrations of MPO, but not compa

Antifibrinolytic Agents↗

Platelet compatibility of an artificial surface modified with functionally active heparin.

Platelet compatibility after coating an artificial material with functionally active heparin was investigated. Blood was circulated in uncoated or heparin coated PVC tubing. In one hour platelet counts decreased from 155 (113-184)x10(9)/l to 124 (100-148)x10(9)/l with uncoated compared to 164 (132-192)x10(9)/l with heparin coated tubing (intergroup p = 0.02). Beta-thromboglobulin increased from 116 (80-148) microg/l to 1039 (757-1298) microg/l with uncoated and to 352 (229-638) microg/l with heparin coated tubing (intergroup p = 0.005). Platelet counts and beta-thromboglobulin correlated closely with complement activation. Solid-phase enzyme immunoassay demonstrated substantial deposition of CD42a/GPIbIX and CD61/GPIIIa on uncoated, but not on heparin coated tubing (intergroup p<0.0005). Scanning electron microscopy demonstrated activated platelets and aggregates on uncoated in contrast to heparin coated tubing, where scattered, unactivated platelets were found. Changes in P-selectin and microparticles were minor. In conclusion, this heparin surface substantially improved platelet compatibility. Markers of choice for in vitro evaluation were platelet counts, beta-thromboglobulin and platelet deposition.

Antigens, CD↗

Complement activation in sudden deafness.

OBJECTIVE: To test whether complement activation is associated with sudden deafness. DESIGN: Plasma samples obtained from patients in the acute phase of sudden deafness were analyzed for complement activation measured by C3bc levels and terminal complement complex. Comparisons were made with plasma samples from healthy controls. PATIENTS: Twenty-five adult patients with unilateral sudden deafness. The criteria for inclusion were symptoms of hearing loss for not longer than 14 days and a hearing loss of 35 dB or more measured at entry. RESULTS: Levels of C3bc were higher in patients compared with controls (P<.001). There were no differences in the formation of terminal complement complex in patients and controls. CONCLUSIONS: The elevated levels of C3bc in patients with sudden deafness indicate an activation of the first part of the complement cascade and therefore suspected inflammatory causes. Measurements of C3bc levels might identify patients with sudden deafness who would benefit from treatment with anti-inflammatory drugs.

Adult↗

Complement activation in injured patients occurs immediately and is dependent on the severity of the trauma.

In order to study the factors related to complement activation, the complement activation products C3bc and TCC were measured in plasma at admittance and during the stay in the intensive care unit in 108 consecutive patients with multiple injuries. These patients were admitted to the surgical department during a 4-month period. Complement activation occurred immediately after the trauma and correlated strongly with the Injury Severity Score and was inversely correlated to the Base Excess. Complement activation also correlated with the number of transfusions. Sepsis caused complement activation later during the stay in hospital. All seven patients developing the adult respiratory distress syndrome (ARDS) had increased complement activation, either on admission or later during the stay in the intensive care unit. Complement activation is known to contribute to organ damage following ischemia and reperfusion. Clinical studies have demonstrated the importance of early restoration of adequate circulation and the present demonstration of a strong negative correlation between complement activation and Base Excess indicates that early restoration of aerobic metabolism may reduce complement activation and the risk for organ dysfunction.

Acid-Base Imbalance↗

Identification of a C-->T mutation in the reactive-site coding region of the C1-inhibitor gene and its detection by an improved mutation-specific polymerase chain reaction method.

Mutations in the C1-inhibitor (C1-INH) gene, leading to low functional levels of C1-inhibitor protein, cause hereditary angioedema (HAE). The disease is characterized by episodic edema in a number of organs. Typically, swellings occur in extremities and face, often accompanied by crampy abdominal pain. Laryngeal edema may lead to suffocation. Type II HAE patients have low functional C1-INH values stemming from only one normal allele. Antigenic C1-INH values, however, are normal or increased owing to the presence of a dysfunctional protein from the mutated allele. The mutations are usually found in exon 8 coding for the amino acids near the reactive centre (P1). Previously, no mutations in the C1-INH gene had been published from the Scandinavian countries. In this work, exon 8 of the C1-inhibitor gene was sequenced in members of two different kindreds, from western and northern Norway, who were suffering from HAE type II. A common point mutation was found within the bait region encoding the reactive centre. The codon CGC was converted to TGC at position 17970, corresponding to an Arg-->Cys replacement which reportedly is the second most frequent type II HAE mutation. This information was utilized to develop a mutation-specific polymerase chain reaction (PCR) for the identification of affected family members. The antisense 17-mer primer (5'-AAGACCAGCAGGGTGCA-3') was successfully applied and AmpliTaq Gold was used in the PCR.

Angioedema↗

Immunoglobulin prolongs survival of pig kidneys perfused ex vivo with human blood.

Intravenous immunoglobulin (IVIG) (Octagam), was used to determine the effect on hyperacute rejection in an ex vivo xenograft model. Six pig kidneys were perfused with IVIG and fresh human AB blood, and six control pig kidneys were simultaneously perfused with albumin and blood from the same donation. The survival of the IVIG-perfused xenografts (median, 6.5 h) was significantly (P = 0.03) longer than the albumin-perfused xenografts (median, 3.5 h). Complement was activated in both groups. The administration of IVIG to the perfused blood resulted in immediate and significantly higher complement activation in the fluid phase as compared with the albumin group. At rejection the fluid phase complement activation was higher in the IVIG group than in the albumin group for C1rs/C1inh complexes, C4bc, Bb and TCC. At the time of rejection both the albumin and the IVIG group demonstrated interstitial tubular haemorrhage, vasculitis or necrosis of glomerular capillaries and glomerular microthrombi. IgM, C1q, C3c, C4 and fibrin were located in arteries and glomeruli and IgG in the interstitium in both groups at rejection. The fluid phase findings are consistent with a modulatory effect of IVIG on complement activation by deviating the classical pathway activation towards the fluid phase. The prolonged survival of the IVIG-perfused kidneys suggests that IVIG may be useful to dampen hyperacute rejection.

Animals↗

High-dose intravenous immunoglobulin treatment activates complement in vivo.

Several complement modulating effects of high-dose intravenous immunoglobulins (IVIG) have been proposed from in vitro studies and experimental animal models. However, the in vivo effects of IVIG on plasma complement in humans are yet not known. We have investigated the in vivo effects of IVIG on complement in seven women with unexplained recurrent spontaneous abortion who were without evidence of autoimmune disease. Samples were obtained before and after the very first infusion of IVIG. There was a marked increase in immunoglobulin G (IgG) from (median and range) 12.4 (9.4-15.9) to 26.8 (22.4-30.0) g/l but no change in immunoglobulin A (IgA) or immunoglobulin M (IgM). A significantly increased complement activation was demonstrated using neoepitope-specific enzyme immunoassays to the activation products C3bc (median increased from 9.8 to 31.2 AU/ml), Bb (0.66-1.66 g/ml), C5a (10.5-12.7 ng/ml), and TCC (0.81-2.19 AU/ml) (P = 0.015 for all). There were no changes in antigenic concentrations of individual complement components or regulators (C1q, C4, C3, C1-inhibitor, C4b-binding protein) and no decrease in complement haemolytic activity (classical and alternative CH50), which were all within the normal range. The classical pathway activation products C1rs/C1-inhibitor complexes, C4bc and C4d were elevated in all patients before IVIG treatment and did not change significantly during treatment. In conclusion, IVIG induced a significant activation of complement in vivo.

Abortion, Habitual↗

Characterization of soluble terminal complement complex assembled in C8beta-deficient plasma and serum.

Sera genetically deficient in either the alpha-gamma or the beta-subunit of complement component C8 virtually lack haemolytic activity. We have studied the formation and the structural organization of the soluble terminal complement complex (TCC) assembled in these sera following activation with cobra venom factor (CVF). The TCC concentration in the activated C8alpha-gamma and C8beta-deficient samples was 0.2% and 4%, respectively, when compared with zymosan-activated normal serum. TCC was purified from the activated C8beta-deficient samples by affinity chromatography and analysed by immunoblotting and enzyme immunoassay. No C8beta was detected in one TCC preparation, while 7% of the normal level was present in the other. The level of the other terminal components, including that of C8alpha-gamma, was normal. The ability of C8alpha-gamma to promote the assembly of TCC in the presence of a limited amount of C8beta or in the apparent absence of this subunit was confirmed using purified components, by mixing C5b6 and either of the purified C8 subunits together with C7 and C9. These data show that soluble TCC can be formed in C8beta-deficient sera that contain little or no C8beta.

Complement C5↗

Anti-TNF treatment of baboons with sepsis reduces TNF-alpha, IL-6 and IL-8, but not the degree of complement activation.

The activation of complement and the release of TNF-alpha, IL-6 and IL-8 are important pathogenic factors behind organ dysfunction in sepsis. The aim of this study was to determine whether infusion of anti-TNF antibodies alters complement activation and plasma concentrations of pro-inflammatory cytokines at high doses of Escherichia coli. Six baboons received intravenously 2 x 10(9) live E. coli bacteria per kg body weight (group 1), in addition five received pretreatment with 1 mg per kg body weight anti-TNF antibodies (group 2), and seven received 5 x 10(8) live E. coli bacteria per kg body weight (group 3). Two hours after the start of infusion of the bacteria, plasma concentrations of C3 activation products, C5a and the terminal SC5b-9 complement complex were increased in groups 1 and 2 (P < 0.05), but there was no significant difference between the groups. At 2 h the levels of TNF-alpha, IL-6 and IL-8 were lower in group 2 compared with group 1 (P<0.05). In group 2 compared with group 1 the TNF-alpha concentrations were, however, higher at 4, 8 and 24 h. The explanation for this phenomenon is probably that TNF-alpha binds to the anti-TNF antibody complex and is released slowly after it has been bound. The study showed that infusion of anti-TNF antibodies reduced the concentrations of TNF-alpha, IL-6 and IL-8, without any detectable influence on complement activation.

Animals↗

Effect of filtration and storage of platelet concentrates on the production of the chemotaxins C5a, interleukin 8, tumor necrosis factor alpha, and leukotriene B4.

BACKGROUND: The production in platelet concentrates (PCs) of C3 activation products (C3bc), terminal complement complex (TCC), and chemotaxins C5a, interleukin (IL)-8, tumor necrosis factor alpha (TNFalpha), and leukotriene B4 (LTB4) and the proposed reduction in concentration of the chemotaxins by white cell reduction were examined. STUDY DESIGN AND METHODS: Samples were collected from supernatants of PCs produced by apheresis (apheresis PCs) or from buffy coats (BC PCs) immediately after the production, after white cell-reduction filtration on Day 1, and after 5-day storage, and examined by enzyme immunoassays. RESULTS: Complement was activated in all PCs during storage, and the concentration of activation products was not influenced by prestorage filtration. In prestorage white cell-reduced BC PCs, only C3bc levels increased. Levels of IL-8, TNFalpha, and LTB4 increased during storage of apheresis PCs, but not in filtered units, except for LTB4. In contrast, levels of IL-8 decreased after storage of filtered BC PCs. C5a correlated significantly with IL-8, which also correlated with TNFalpha and LTB4. CONCLUSION: Both C5a and TNFalpha generation in apheresis PCs seem to induce white cell IL-8 production, which mediates cellular LTB4 release. Prestorage white cell reduction is recommended for reducing chemotactic cytokine and leukotriene levels in all PCs. Production of BC PCs is recommended to achieve less complement activation, which is not affected by filtration.

Blood Platelets↗

Complement activation and release of interleukin-6 and tumour necrosis factor-alpha in drained and systemic blood after major orthopaedic surgery.

OBJECTIVE: To measure the concentration of complement activation products C3bc and terminal complement complex (TCC) and the cytokines interleukin 6 (IL-6) and tumour necrosis factor alpha (TNF-alpha) in systemic and drained wound blood for the first six hours after a major orthopaedic operation. DESIGN: Prospective study. SETTING: University hospital, Norway. PATIENTS: 8 patients operated on for thoracic scoliosis. MAIN OUTCOME MEASURE: Concentrations of complement activation products, IL-6 and TNF-alpha in arterial (systemic) and drained (local) blood were measured at wound closure and 1, 2, 4, and 6 hours postoperatively. RESULTS: C3bc and TCC were 10 times higher, and IL-6 showed extreme values, in drained compared with arterial blood. The concentration of TNF-alpha did not increase significantly, either in drained or in arterial blood. The white cell count (WCC) increased threefold in both drained and arterial blood compared with arterial control values before operation. CONCLUSION: Complement activation and IL-6 release after surgical trauma differ significantly in local and systemic blood samples. Conclusions based only on systemic findings may be limited.

Adolescent↗

Removal of activated complement from shed blood: comparison of high- and low-dilutional haemofiltration.

BACKGROUND: Perioperative blood salvage is associated with release of inflammatory mediators. Depending on type of processing, the complement system is activated to some extent in the final blood product. The aim of the present study was to evaluate a haemofiltration technique concerning complement system activation and whether the volume of added saline will have an influence on the elimination of activated complement during processing. METHODS: Sixteen patients undergoing total hip arthroplasty received wound blood salvaged intraoperatively with a haemofiltration technique. Saline was added to the reservoir for washing in a ratio of 1:1 or 5:1 of estimated blood volume. Samples for determination of the anaphylatoxins C3a and C5a, and the terminal SC5b-9 complement complex (TCC) were drawn from the patients, the collected blood, the ultrafiltrate and the processed blood. RESULTS: Increased concentrations of C3a, C5a and TCC were found in aspirated and processed blood. Haemofiltration did not reduce the concentrations of these factors, except that of C3a in the group where saline was added in a ratio of 5:1. There were no increased concentrations of C3a, C5a or TCC in the patient plasma after reinfusion. No differences in blood pressure, heart rate, pH, arterial oxygen tension, arterial carbon dioxide tension, or base excess were found in association with reinfusion of the blood. CONCLUSION: Collected shed blood washed through haemofiltration contained moderately elevated concentrations of C3a, C5a and TCC. Reinfusion of the blood neither led to increased systemic concentrations of complement activation products, nor to disturbances in haemodynamic or biochemical parameters.

Acid-Base Equilibrium↗

Complement and biocompatibility.

Blood contact with foreign surfaces induces a certain degree of activation of the defence systems including complement. Recent data using complement specific inhibitors have shown that complement is not only associated with, but in fact contributes to the whole body inflammatory reaction seen as a complication of cardiopulmonary bypass (artificial surfaces) and is responsible for the hyperacute rejection of xenografts (foreign endothelium). Complement activation products, particularly the terminal SC5b-9 complex (TCC), is a sensitive indicator of bioincompatibility. Modifications of the artificial surfaces by coating with heparin improves both coagulation and complement compatibility. The use of specific complement inhibitors in general improves biocompatibility both of artificial materials and foreign endothelium.

Animals↗

Leucocyte filtration during cardiopulmonary bypass hardly changed leucocyte counts and did not influence myeloperoxidase, complement, cytokines or platelets.

In some patients, coronary artery bypass surgery induces postoperative organ dysfunction despite an apparently adequate revascularization and good haemodynamic performance. This complication may be caused by activation of the body's inflammatory systems on blood contact with large foreign surfaces in the extracorporeal circuit. Activated leucocytes may play an important role in organ damage, and it is conceivable that leucocyte removal by filtration may decrease the potential side-effects of cardiopulmonary bypass (CPB). The aim of the present study was to investigate possible effects of leucocyte filtration during the whole CPB period in elective coronary artery bypass surgery on biochemical and clinical parameters. Forty patients were randomized to extracorporeal circulation using a leucocyte-depleting filter (group L, n = 20) or to extracorporeal circulation with no leucocyte filter (group C, n = 20). In the leucocyte-depleted group, the mean total white blood cell counts increased from 6.3 (95% confidence interval, 5.5-7.0) x 10(9)/l to 7.0 (5.7-8.3) x 10(9)/l during extracorporeal circulation and in the control group from 6.3 (5.2-7.3) x 10(9)/l to 8.5 (7.2-9.8) x 10(9)/l. The intergroup difference was not statistically significant (p = 0.84). A substantial increase in concentrations of interleukin-6, myeloperoxidase and complement activation products were observed in both groups without statistically significant intergroup differences. It is concluded that the leucocyte-depletion filter did not cause a significant reduction of circulating white blood cells during CPB, and there were no significant differences between the groups with respect to the inflammatory markers studied.

Aged↗

Improved blood preservation with 0.5CPD erythro-sol. Coagulation factor VIII activity and erythrocyte quality after delayed separation of blood.

BACKGROUND AND OBJECTIVES: Delay between blood collection and the separation of its components may result in lowered yield of factor VIII (FVIII) and loss of 2,3-biphosphoglycerate (2,3-BPG). This study was to see whether the use of 0.5 CPD resulted in better preservation of FVIII and maintenance of 2,3-BPG. MATERIALS AND METHODS: 55 units of blood were collected in 0.5CPD and 48 in CPD SAG-M. Ten of the collections were paired, so that the same donors were bled in a single session partly in an 0.5CPD system and partly in CPD SAG-M. After collection, the blood was promptly cooled to 20 degrees C and stored at that temperature for up to 24 h. RESULTS: Preservation of FVIII activity was significantly better in 0.5CPD compared with CPD. The content of von Willebrand factor was stable in the anticoagulant solutions for 24 h at that temperature. Plasma separated from both media had how levels of prothrombin fragment 1 + 2 and complement activation. Paired collections substantiated previous reports that red cell storage is significantly improved in 0.5CPD compared with CPD SAG-M with respect to 2,3-BPG and haemolysis. CONCLUSIONS: Red cell metabolism and oxygen-releasing capacity are kept at acceptable levels in 0.5CPD blood for 24 h at 20 degrees C before component separation. The concentration of red cell 2,3-BPG remained at normal or slightly subnormal levels during further storage in 0.5CPD at 4 degrees C for 2-4 weeks before gradual decay to an average of 39% at 48 days.

2,3-Diphosphoglycerate↗