PubMed Health⌕ Search

Biomedical subjects

T E Parker

Publications and source records attributed to T E Parker.

5 recordsLinked to original sources

Single-atom optical clock with high accuracy.

For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.

Journal Article↗

Multiple-scattering effects on infrared scattering measurements used to characterize droplet size and volume fraction distributions in diesel sprays.

We quantify the maximum error due to multiple-scattering effects for an infrared scattering droplet izing technique. Errors in Sauter mean diameters (SMDs) and liquid volume fractions were estimated lased on experimentally determined polarization properties of the scattered light. Light that is multiply scattered from spherical particles becomes randomly polarized, whereas singly scattered light from a spherical particle contains no cross-polarization scattering component. Therefore measurement of the cross-polarization component (in this case parallel) of the scattering signal is a measure of the multiply scattered light. A ratio of parallel to perpendicular polarized scattered light was experimentally determined and used to calculate an error due to multiple scattering. The infrared scattering measurements and polarization measurements used to quantify the multiple-scattering errors were applied to a typical diesel spray that was injected into three different background conditions: a room ambient condition; a room-temperature, high-pressure condition; and a combusting condition. Droplet SMD, liquid volume fraction, and multiple-scattering errors were determined for a number of locations within the spray; results indicate that the combusting case is negligibly affected by multiple scattering. However, the room ambient case exhibited notable errors due to multiple scattering near the centerline of the spray, and the high-pressure case demonstrated susceptibility to multiple scattering throughout all regions investigated. It is important to note, however, that multiple-scattering errors in many cases translate into relatively small effects on the reported droplet sizes.

Journal Article↗

Measurement of dynamic end-to-end cavity phase shifts in cesium-fountain frequency standards.

We have measured a previously unobserved systematic frequency shift in our cesium-fountain frequency standard, NIST-F1. This shift, predicted theoretically previously, mimics the well-known end-to-end phase shift in atomic beam standards when synchronous thermal transients are present. Detuning the microwave cavity several megahertz from resonance reduces this effect to the deltaf/f = 1o(-16) level.

Letter↗

Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock.

Over a two-year duration, we have compared the frequency of the 199Hg+ 5d(10)6s (2)S(1/2)(F=0)<-->5d(9)6s(2) (2)D(5/2)(F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/-7 x 10(-15) yr(-1) (1sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs)(m(e)/m(p))alpha(6.0) at the same level.

Journal Article↗

Surreptitious diuretic ingestion and pseudo-Bartter's syndrome.

A patient with profound hypokalemia satisfied the criteria for Bartter's syndrome, including hyperreninemia, aldosteronism, normal blood pressure, and hyperplasia of the juxtaglomerular apparatus. Two screening tests of urine and one of plasma for diuretic agents gave negative results. A third urinary sample gave negative results for thiazide but positive for furosemide; the fourth and fifth samples gave negative results for furosemide but positive for thiazide. Urinary prostaglandin excretion was normal. We conclude that this apparent case of Bartter's syndrome was caused by long term surreptitious diuretic ingestion and suggest this may occur more frequently than is generally appreciated.

Adult↗