PubMed Health⌕ Search

Biomedical subjects

T Ebbers

Publications and source records attributed to T Ebbers.

5 recordsLinked to original sources

Noninvasive measurement of time-varying three-dimensional relative pressure fields within the human heart.

Understanding cardiac blood flow patterns is important in the assessment of cardiovascular function. Three-dimensional flow and relative pressure fields within the human left ventricle are demonstrated by combining velocity measurements with computational fluid mechanics methods. The velocity field throughout the left atrium and ventricle of a normal human heart is measured using time-resolved three-dimensional phase-contrast MRI. Subsequently, the time-resolved three-dimensional relative pressure is calculated from this velocity field using the pressure Poisson equation. Noninvasive simultaneous assessment of cardiac pressure and flow phenomena is an important new tool for studying cardiac fluid dynamics.

Atrial Function, Left↗

Estimation of relative cardiovascular pressures using time-resolved three-dimensional phase contrast MRI.

Accurate, easy-to-use, noninvasive cardiovascular pressure registration would be an important addition to the diagnostic armamentarium for assessment of cardiac function. A novel noninvasive and three-dimensional (3D) technique for estimation of relative cardiovascular pressures is presented. The relative pressure is calculated using the Navier-Stokes equations along user-defined lines placed within a time-resolved 3D phase contrast MRI dataset. The lines may be either straight or curved to follow an actual streamline. The technique is validated in an in vitro model and tested on in vivo cases of normal and abnormal transmitral pressure differences and intraaortic flow. The method supplements an intuitive visualization technique for cardiovascular flow, 3D particle trace visualization, with a quantifiable diagnostic parameter estimated from the same dataset.

Adult↗

Three dimensional flow in the human left atrium.

BACKGROUND: Abnormal flow patterns in the left atrium in atrial fibrillation or mitral stenosis are associated with an increased risk of thrombosis and systemic embolisation; the characteristics of normal atrial flow that avoid stasis have not been well defined. OBJECTIVES: To present a three dimensional particle trace visualisation of normal left atrial flow in vivo, constructed from flow velocities in three dimensional space. METHODS: Particle trace visualisation of time resolved three dimensional magnetic resonance imaging velocity measurements was used to provide a display of intracardiac flow without the limitations of angle sensitivity or restriction to imaging planes. Global flow patterns of the left atrium were studied in 11 healthy volunteers. RESULTS: In all subjects vortical flow was observed in the atrium during systole and diastolic diastasis (mean (SD) duration of systolic vortex, 280 (77) ms; and of diastolic vortex, 256 (118) ms). The volume incorporated and recirculated within the vortices originated predominantly from the left pulmonary veins. Inflow from the right veins passed along the vortex periphery, constrained between the vortex and the atrial wall. CONCLUSIONS: Global left atrial flow in the normal human heart comprises consistent patterns specific to the phase of the cardiac cycle. Separate paths of left and right pulmonary venous inflow and vortex formation may have beneficial effects in avoiding left atrial stasis in the normal subject in sinus rhythm.

Adult↗

Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI.

The flow patterns in the human heart are complex and difficult to visualize using conventional two-dimensional (2D) modalities, whether they depict a single velocity component (Doppler echocardiography) or all three components in a few slices (2D phase contrast MRI). To avoid these shortcomings, a temporally resolved 3D phase contrast technique was used to derive data describing the intracardiac velocity fields in normal volunteers. The MRI data were corrected for phase shifts caused by eddy currents and concomitant gradient fields, with improvement in the accuracy of subsequent flow visualizations. Pathlines describing the blood pathways through the heart were generated from the temporally resolved velocity data, starting from user-specified locations and time frames. Flow trajectories were displayed as 3D particle traces, with simultaneous demonstration of morphologic 2D slices. This type of visualization is intuitive and interactive and may extend our understanding of dynamic and previously unrecognized patterns of intracardiac flow.

Heart↗

Pitfalls in Doppler evaluation of diastolic function: insights from 3-dimensional magnetic resonance imaging.

Ultrasound-Doppler assessment of diastolic function is subject to velocity errors caused by angle sensitivity and a fixed location of the sample volume. We used 3-dimensional phase contrast magnetic resonance imaging (MRI) to evaluate these errors in 10 patients with hypertension and in 10 healthy volunteers. The single (Doppler) and triple (MRI) component velocity was measured at early (E) and late (A) inflow along Doppler-like sample lines or 3-dimensional particle traces generated from the MRI data. Doppler measurements underestimated MRI velocities by 9.4% +/- 8.6%; the effect on the E/A ratio was larger and more variable. Measuring early and late diastolic inflows from a single line demonstrated the error caused by their 3-dimensional spatial offset. Both errors were minimized by calculating the E/A ratio from maximal E and A values without constraint to a single line. Alignment and spatial offset are important sources of error in Doppler diastolic parameters. Improved accuracy may be achieved with the use of maximal E and A velocities from wherever they occur in the left ventricle.

Adult↗