Semirigid instrumentation in the management of lumbar spinal conditions combined with circumferential fusion. A multicenter study.

STUDY DESIGN: Patients with the diagnosis of degenerative disc conditions or spondylolisthesis undergoing circumferential fusion with posterior pedicle screw fixation using a semirigid rod were reviewed. OBJECTIVES: To determine the effectiveness of this approach in achieving a spinal fusion and satisfactory clinical outcome, and to determine the complications associated with the procedure. SUMMARY OF BACKGROUND DATA: The use of instrumentation to stabilize the lumbar motion segments and thereby enhance the fusion rate has been proposed in a number of studies. Semirigid fixation was believed to be effective in achieving these objectives without concern for stress-shielding, which was suggested by some authors using rigid fixation systems. METHODS: Patients who required spinal fusion with anterior and posterior approaches because of specific lumbar pathology or previous surgeries were selected. The surgery consisted of an anterior interbody fusion using allograft, followed by a posterolateral fusion and pedicle screw fixation. Fusion was determined by continuity of trabecular bridging, and outcomes were determined by pain reduction and return to previous levels of activity. Fusion was considered solid if the two posterolateral areas were fused (Zones one and two), if the anterior interbody area was fused (Zone three), or if all three zones were fused. Complications were documented during and after surgery. RESULTS: Sixty-two percent of patients had previous surgery with 25% of these patients having a diagnosis of pseudarthrosis. Fifty-five percent of patients had two or more levels fused, and 43% were heavy smokers. Ninety-seven percent of patients had successful fusions. Pain was significantly reduced on a pain analogue scale from 7.1 to 2.1 in the back and from 5.8 to 1.5 in the leg (p < 0.006 and 0.0001, respectively). Fifty-nine percent of patients returned to their previous level of activity, and 18% returned to lighter work or job retraining, for a total of 77% returning to the same or lighter levels of activity. Complications included metal failure, 4.9%; neurologic deficit, 1.2%; deep infection, 1.2%; deep venous thrombosis, 4.9%; and vascular injury, 2.4%. Fatal pulmonary embolus occurred in one patient. CONCLUSION: This technique produces a satisfactory fusion rate (97%) and a good clinical outcome based on pain reduction and return to a satisfactory level of activity (77%). It is associated with few, but significant, complications that compare well with other reported series in a difficult group of patients. This procedure should be reserved for patients who are considered to be at high risk for not achieving spinal fusion.

Adolescent↗

Late infection of spinal instrumentation by hematogenous seeding.

Six cases of late spinal infection following instrumentation are described. In all cases, there was a delay of at least 10 months between surgery and the clinical development of sepsis. In 5 of the 6 cases, a distant focus of infection could be identified. Two patients had active intravenous drug usage, two patients were paraplegic with neurogenic bladders, and one patient had an episode of pyelonephritis secondary to renal calculi two months prior to presentation. In no instance was there any preceding breakdown of overlying skin. This previously unreported phenomenon is an extremely rare but major complication of spinal surgery.

Adolescent↗

Occipitocervical fusion with a five-millimeter malleable rod and segmental fixation.

Although occipitocervical fusion is frequently used for instability of the upper cervical spine and the occipitocervical articulation, most currently used techniques have one or more of the following disadvantages: the necessity for sublaminar wires, the use of occipital screws, a fixed angle of instrumentation, or the necessity for routine postoperative halo immobilization. Moreover, many reported techniques are associated with a high rate of nonunion or instrumentation failure. We present our experience with a technically simple method of obtaining rigid occipitocervical arthrodesis using a 5-mm malleable rod that is fixed to the skull by a pair of wires passed through four suboccipital burr holes. Segmental spinal fixation is achieved with Wisconsin interspinous wires and is occasionally supplemented with sublaminar wires. Supplemental autogenous bone graft is used in all cases. A cervical collar is routinely used for postoperative immobilization. The results of treatment were retrospectively reviewed in 16 patients with an average age of 49.4 years (range, 9-69). Mean follow-up was 24 months (range, 12-36 mo). The indication for fusion was instability of the occiput-C1-C2 complex as a result of Chiari malformation, rheumatoid disease, skull base tumor resection, basilar invagination, ankylosing spondylitis, Down's syndrome, cervical laminectomy, and trauma. The average number of levels fused was 5.4 (range, O-C3 to O-T3). Successful occipitocervical arthrodesis was achieved in all but one of the surviving patients. The single patient with a pseudarthrosis was successfully managed with supplemental bone grafting and halo immobilization. There were two deaths from medical complications in chronically ill patients. Other complications included one postoperative instrumentation loosening, one myocardial infarction, and one superficial occipital decubitus. In conclusion, rodding and segmental interspinous wiring is an effective, technically simple method of obtaining rigid occipitocervical fixation, which obviates the need for bulky orthoses.

Adolescent↗

Pullout strength comparison of two methods of orienting screw insertion in the lateral masses of the bovine cervical spine.

We undertook a biomechanical study to compare the pullout strength of 3.5-mm AO screws placed in two different orientations within the bovine cervical spine. The first set of screws were oriented obliquely and passed through the lateral mass, as recommended by the AO group. The orientation of the second set was anterior to posterior through the lateral mass, as recommended by Roy-Camille. All screw holes were drilled and tapped by a spinal surgeon experienced with both techniques. Pullout force was measured on an Instron materials testing machine using a self-centering screw-holding chuck and loading rate of 0.833 mm/sec. Although the bone strength in the Roy-Camille orientation was greater (46.7 N/mm versus 36.1 N/mm, p < 0.05), the overall mean pullout force for the AO orientation was greater (607 N versus 471 N, p < 0.025) due to the longer length of bone available for screw purchase (17.0 mm versus 10.3 mm).

Animals↗

Using tissue expanders in spinal surgery for deficient soft tissue or postirradiation cases.

Prior irradiation and scarring can complicate wound closure following spinal surgery. Implanted tissue expanders were used six times in four patients to aid skin closure. Three patients had prior irradiation for cancer, and one had myelomeningocele. The average interval between placement and removal of the expanders was 46 days. Two late failures occurred because of prominent hardware. These expanders may provide adequate myocutaneous covers following spinal surgery in difficult cases.

Adult↗