Elevated serum non-esterified fatty acid (NEFA) levels associated with a negative energy balance (NEB) may affect ovarian function and hence reproductive performance in high-yielding dairy cows. We have investigated the individual and combined effects of the three major NEFAs on bovine theca cell proliferation and steroidogenesis in vitro. Theca cells from healthy large follicles (>8 mm) obtained from slaughterhouse ovaries were cultured in serum free medium in the presence of 0, 50, 150 and 200 microM of palmitic acid (PA; C16:0); 0, 50, 150 and 250 microM of stearic acid (SA; C18:0); and/or 0, 50, 150 and 250 microM of oleic acid (OA; C18:1). Progesterone and androstenedione concentrations were measured in spent medium after 48 h of culture and cell numbers were determined spectrophotometrically per culture well. Cell viability was assessed by annexin-V FITC/propidium iodide staining. Only the treatment with 200 microM of PA inhibited cell proliferation (P<0.001) when tested individually, both of the mixtures tested (M1=100 microM of PA, 130 microM of SA and 140 microM of OA; M2=200 microM PA, 260 microM of SA and 280 microM of OA) reduced cell numbers (P<0.001). Progesterone and androstenedione production, both per well and per 10(4) cells, were not affected by any of the treatments, with the exception of M2. This mixture reduced progesterone production per well and per 10(4) cells (P<0.05). The effects observed were most likely caused by the cytotoxic action of the NEFAs, as demonstrated by the increased percentage of early apoptotic (M1) and late apoptotic/necrotic cells (M1 and M2) in the combination treatments (P<0.05). When combined, elevated physiological concentrations of PA, SA and OA can modulate theca cell proliferation and steroidogenesis in vitro by reducing theca cell viability. These NEFAs may be one of the mediators through which NEB compromises ovarian functioning and thus fertility in high-yielding dairy cows.

Androstenedione↗

Validation of 5 routine assays for serum free testosterone with a candidate reference measurement procedure based on ultrafiltration and isotope dilution-gas chromatography-mass spectrometry.

BACKGROUND/METHOD: The analytical validity of free testosterone (FTe) analog immunoassays is subject to much controversy. We revisited the validation of 4 analog assays and 1 FTe calculation procedure with a metrologically traceable reference measurement procedure (RMP) based on ultrafiltration and isotope dilution-mass spectrometry for direct measurement of Te in the ultrafiltrate. To this end, we performed split-sample measurements of 40 male sera. RESULTS: Deming regression showed that 3 of the immunoassays had moderate to good correlation (0.8474 < or = r < or = 0.9241) with the RMP; however, the slope was markedly below 1. The FTe calculation procedure was in good agreement with this result. The Sy/x values for all assays were higher than the combined imprecision values, which indicate their susceptibility to matrix-related effects. CONCLUSIONS: The study demonstrated substantial differences in analytical quality of FTe assays; however, the results suggested that after extending the validation with a larger variety of samples, recalibration of some analog assays might be worth further investigation.

Adult↗

Determination of user requirements for the secure communication of electronic medical record information.

Health professionals need to have accurate patient data in order to make the right diagnosis and to give an optimal treatment. In many cases, the 'medical' record, whether in electronic form or paper form is distributed over several health care providers and health care enterprises. Technically, there are several ways to provide access to remote record information or parts thereof. Legislation however puts restrictions on the communication of personal information in order to protect the privacy of the patient. This paper gives an overview of requirements and constraints when communicating electronic medical record information and summarises the findings of the SEMRIC project in determining requirements from a number of practical cases.

Computer Communication Networks↗

Evolution of the Intranet in the University Hospital of Gent.

The explosive development of the internet in recent years has lead to the production of massive collections of web-based tools and development know-how. Implementing an Intranet solution within a health care environment offers tremendous advantages for internal information management, distribution and collaborative computing. Easy adaptability, scalability and the low development cost allow easy integration into existing health care structures. A key aspect of the UZ Gent Intranet is its transparent interaction with the currently implemented HIS thus providing an open gateway to the future.

Belgium↗

Automation of toxicological screenings on a Hewlett Packard Chemstation GC-MS system.

OBJECTIVES: To optimize the interpretation of GC-MS toxicological screenings (i.e., to facilitate ion specific queries, create custom reports specifically adapted to each confirmation procedure, and eliminate redundant and/or inaccurate data on library search reports). DESIGN AND METHODS: The MS Chemstation software of the Hewlett Packard 5972 is constructed in a modular way. We made extensive modifications to two modules, the data analysis and the report modules, using the built-in MS Chemstation macro language. RESULTS: Ion specific queries were automated for over 60 commonly encountered analytes. Custom reports were created for the confirmation of positive drugs-of-abuse immunoassay results. With the incorporation of decision support rules into the data processing and the reporting phases, we obtained sensitive, accurate, and concise reports. CONCLUSIONS: The MS Chemstation software can be tailored to the needs of each individual application. The incorporation of a rule-based decision support system enhances the quality of the GC-MS toxicological screenings and results in faster, easier, and more reliable processing.

Gas Chromatography-Mass Spectrometry↗

The research in semantics behind the OpenLabs coding system.

The OpenLabs coding system is an established, comprehensive, dynamic, flexible, open, multilingual European system which is tailored to meet the electronic data interchange (EDI) needs of medical laboratory users. The OpenLabs coding system, having many specific, independent classes and considerable flexibility, serves two different objectives: (i) unambiguous coding of entities present in messages used for EDI in clinical pathology; and (ii) interfacing with other nomenclatures and coding schemes to map concepts between different systems.

Classification↗

Logical observation identifier names and codes (LOINC) database: a public use set of codes and names for electronic reporting of clinical laboratory test results.

Many laboratories use electronic message standards to transmit results to their clients. If all laboratories used the same "universal" set of test identifiers, electronic transmission of results would be greatly simplified. The Logical Observation Identifier Names and Codes (LOINC) database aims to be such a code system, covering at least 98% of the average laboratory's tests. The LOINC database should be of interest to hospitals, clinical laboratories, doctors' offices, state health departments, governmental healthcare providers, third-party payors, organizations involved in clinical trials, and quality assurance and utilization reviewers. The fifth release of the LOINC database, containing codes, names, and synonyms for approximately 6300 test observations, is now available on the Internet for public use. Here we describe the LOINC database, the methods used to produce it, and how it may be obtained.

Clinical Laboratory Information Systems↗

Rapid identification of bacteria of the Comamonadaceae with amplified ribosomal DNA-restriction analysis (ARDRA).

Ribosomal rRNA gene fragments (rDNA) encompassing the 16S rDNA, the 16S-23S rDNA spacer region and part of the 23S rDNA of 95 strains belonging to 13 well-described taxa of the eubacterial family Comamonadaceae (beta subclass of the Proteobacteria or rRNA superfamily III) were enzymatically amplified using conserved primers. The fragments of approximately 2400 base pairs were subjected to restriction analysis. Restriction fragment length patterns obtained with HinfI enabled us to distinguish 9 of the 13 taxa studied. Restriction with CfoI was necessary to differentiate Acidovorax delafieldii from A. temperans and Hydrogenophaga flava from H. pseudoflava. The results indicate that amplified rDNA restriction analysis is a simple and reliable tool for the identification of bacterial species.

Base Sequence↗

Implantable cardioverter defibrillator: data storage and retrieval with Patientlog.

A pacemaker management system (Patientlog), implemented on a IBM personal computer (AT), was adapted for the control and the administrative management of patients with an implantable cardioverter defibrillator (ICD). Several parameters used for pacemakers were also suitable for ICDs, while some fields were defined within the available frame of the database, to cope with the specific technical information of ICDs. "Intervention-cards" display diagnostic (threshold) as well as complex surgical information (approach, lead systems, etc.). "Follow-up-cards" present charge time and the number of shocks in such a way that decision making is very easy. Fourteen patients were followed with a total of 21 interventions, six different types of devices, and more than 150 follow-ups. A correct control of ICD functions is easy. The system is adapted for programmable ICDs. Updated reports containing necessary information are generated immediately after each procedure or follow-up.

Database Management Systems↗

Development of the Logical Observation Identifier Names and Codes (LOINC) vocabulary.

The LOINC (Logical Observation Identifier Names and Codes) vocabulary is a set of more than 10,000 names and codes developed for use as observation identifiers in standardized messages exchanged between clinical computer systems. The goal of the study was to create universal names and codes for clinical observations that could be used by all clinical information systems. The LOINC names are structured to facilitate rapid matching, either automated or manual, between local vocabularies and the universal LOINC codes. If LOINC codes are used in clinical messages, each system participating in data exchange needs to match its local vocabulary to the standard vocabulary only once. This will reduce both the time and cost of implementing standardized interfaces. The history of the development of the LOINC vocabulary and the methodology used in its creation are described.

Classification↗

Comparison of a recombinant thromboplastin with Thrombotest for oral anticoagulant control.

Thrombotest results expressed in international normalized ratio (INR) values, obtained in 108 patients on oral anticoagulant treatment, were compared with prothrombin time (PT) results with a recombinant thromboplastin. The former results were obtained on an Amelung coagulometer, the latter on a photo-optical instrument. Using the Thrombotest method, performed within 2 h after sampling as the reference method, a first group of 63 patients had an INR value between 2 and 4. This group was considered as adequately anticoagulated and served as a true positive population in further analysis. The remaining 45 patients (true-negative group) had an INR value below 2 or higher than 4 and could thus be considered as inadequately anticoagulated. Using these definitions, a sensitivity of 86% and a specificity of 96% could be calculated for the PT with the recombinant thromboplastin. All tests from patients on oral anticoagulant treatment were also performed after 24 h storage of the blood or plasma samples at room temperature. When we compared the reference Thrombotest results with those of the late Thrombotest and the late PT recombinant thromboplastin, sensitivities of 86 and 86% as well as specificities of 91 and 96% were found, respectively. In conclusion, PT with a recombinant thromboplastin on a photo-optical instrument, even after prolonged storage of the plasma samples at room temperature, can be considered as suitable for oral anticoagulation control.

Administration, Oral↗

Recombinant humane thyrotropin (rhtSH) a new aid in the diagnosis and treatment of thyroid carcinoma with radio-iodine.

By example of two cases a newly available tool, the recombinant humane thyroid stimulating hormone (rhTSH) is discussed in its use as an adjunct in diagnosing and treating differentiated thyroid carcinoma with radio-iodine. This product is an easier and safe alternative to the necessary rise of TSH induced by thyroid hormone withdrawal and concurrent hypothyroidism. Although discrepancies in favour of the classical approach have been demonstrated in some patients, the clinical relevancy of these must be weighted against the advantage of avoiding undesirable symptoms and possible tumour growth by the use of rhTSH. The role of rhTSH in the follow-up diagnosis and radioiodine treatment of thyroid carcinoma will undoubtedly increase in importance.