PubMed Health⌕ Search

Biomedical subjects

T Fuerst

Publications and source records attributed to T Fuerst.

At least 19 recordsLinked to original sources

The prediction of visceral fat by dual-energy X-ray absorptiometry in the elderly: a comparison with computed tomography and anthropometry.

INTRODUCTION: Effective methods for assessing visceral fat are important to investigate the role of visceral fat for the increased health risks in obesity. Techniques for direct measurement of soft tissue composition such as CT or MRI are expensive, time-consuming or require a relatively high radiation dose. Simple anthropometric methods, such as waist-to-hip ratio, waist circumference or sagittal diameter are widely used. However, these methods cannot differentiate between visceral and subcutaneous fat and are less accurate. The aim of the present study is to investigate whether the dual-energy X-ray absorptiometry (DXA) method, possibly combined with anthropometry, offers a good alternative to CT for the prediction of visceral fat in the elderly. METHODS: Subjects were participants in the Health ABC-study, a cohort study of black and white men and women aged 70-79, investigating the effect of weight-related health conditions on disablement. Total body fat and trunk fat were measured by DXA using a Hologic QDR 1500. A 10 mm CT scan at the L4-L5 level was acquired to measure visceral fat and total abdominal fat. Weight, height, sagittal diameter and waist circumference were measured using standard methods. Fat in a manually defined DXA subregion (4 cm slice at the top of iliac crest) at the abdomen was calculated in a sub-group of participants (n=150; 50% male; 45.3% Afro-American/54.7% Caucasian, age 70-79 y). This subregion, the standard trunk region and total fat were used as indicators of visceral fat. RESULTS: Total abdominal fat by DXA (subregion) was strongly correlated with total abdominal fat by CT (r ranging from 0.87 in white men to 0.98 in black women). The DXA subregion underestimated total abdominal fat by 10% compared to the CT slice. The underestimation by DXA was seen especially in people with less abdominal fat. The association of visceral fat by CT with the DXA subregion (r=0.66, 0.78, 0.79 and 0.65 for white and black men and women, respectively) was comparable with the association of the CT measure with the sagittal diameter (r=0.74, 0.70, 0.84 and 0.68). Combining DXA measurements with anthropometry gave only limited improvement for the prediction of visceral fat by CT compared to univariate models (maximal increase of r(2) 4%). CONCLUSION: DXA is a good alternative to CT for predicting total abdominal fat in an elderly population. For the prediction of visceral fat the sagittal diameter, which has a practical advantage compared to DXA, is just as effective.

Abdomen↗

Influence of region of interest and bone size on calcaneal BMD: implications for the accuracy of quantitative ultrasound assessments at the calcaneus.

There is considerable technological diversity among quantitative ultrasound (QUS) devices used to assess osteoporosis. Because the distance between the transducer and the footplate remains constant, the location of the calcaneus measured will vary with foot size. This study was designed to quantify the variation in bone mineral density (BMD) between a manufacturer's region of interest (ROI_M), which is fixed relative to the footplate, and an anatomical region of interest (ROI_A), which is defined as 20% of calcaneal length. The effect of foot length and width on QUS variables measured using two Food and Drug Administration cleared QUS devices, the Sahara (Hologic) and the Achilles+ (Lunar) was assessed. 26 healthy subjects (12 male and 14 female), aged 22-54 years (35.6+/-10 years) and with foot lengths of 21.5 cm to 29.7 cm (25.1+/-2.3 cm) were recruited. QUS assessments were performed at the right calcaneus. In addition, a Hologic 4500 densitometer was used to measure the BMD of the calcaneus in the ROI_M and ROI_A. The sizes of the ROIs were approximated to the sizes of the transducers of the Sahara and Achilles+ devices. The results showed a significant difference in BMD between the two ROI locations for the Sahara device (BMD 0.642+/-0.135 g cm(-2) vs 0.616+/-0.114 g cm(-2), p=0.014), but no significant difference was found in BMD between the two locations for the Achilles device (BMD 0.661+/-0.120 g cm(-2) vs 0.662+/-0.123 g cm(-2), p=0.818). At the ROI_A, there was a significant difference in BMD between the two QUS devices (p<0.001). The correlation between QUS variables and BMD was slightly higher for the ROI_M (r=0.68-0.79, since this is site-matched) than the ROI_A (r=0.59-0.70) for the Achilles device, while for the Sahara device the correlations were r=0.35-0.40 and r=0.51-0.54, respectively. The smaller ROI of the Sahara device resulted in more than 50% of the subjects having BMD differences of greater than 5% between the ROI_A and the ROI_M, compared with only 20% of the subjects on the Achilles device. ROIs containing cortical bone edge and other soft tissues were found in 58% of cases for the Achilles device and 46% of cases for the Sahara device. The greatest differences occurred in very small and very large feet. Calcaneal length correlated significantly with Sahara speed of sound (SOS), and heel width correlated significantly with Achilles SOS. Heel width also correlated significantly with Sahara broadband ultrasound attenuation (BUA) but not Achilles+ BUA. These results suggest that variation in ROI and bone size might affect the accuracy of QUS measurements, since the calcaneus is heterogeneous both in terms of its external geometry and its internal structure and density.

Adult↗

Is quantitative ultrasound dependent on bone structure? A reflection.

Trabecular bone plays a significant role in maintaining bone structural integrity. Its density is a significant determinant of bone strength and fracture risk, but there is still unexplained variance. It has been suggested that the ability to measure structural information will improve the estimation of bone strength and fracture risk. Quantitative ultrasound (QUS) is a mechanical wave that can be influenced by bone structure, in addition to bone mineral density (BMD). This article reviews the evidence in the literature supporting or refuting this assumption. Theoretically, the propagation of QUS is influenced by both structure and density of the medium. QUS measurement in vivo shows weak but significant association with axial BMD. However, the association becomes stronger when measured in vitro. Broadband ultrasound attenuation (BUA) exhibits a nonlinear relationship with density over a large density range. When cubes of cancellous bone are measured in the three orthogonal directions, both BUA and speed of sound (SOS) show significant anisotropy which mirrors mechanical anisotropy. QUS has also been shown to correlate significantly with structural parameters measured by histomorphometry. However, structure remains a significant predictor after adjustment for BMD mainly in bovine samples. Other studies using phantoms of bone samples have also demonstrated that QUS is dependent on structure. There is preliminary indication that fractal dimensions are significantly associated with QUS. The ultimate usefulness of structural dependence of QUS will be in its ability to improve bone strength estimation above and beyond density. There is ample evidence documenting the ability of QUS to predict bone strength in vitro. BMD is a significant predictor of bone strength and the additive value of structure in estimating bone strength is variable. Clinically, ultrasound of the calcaneus is measured in one direction (medio-lateral) and the structural variation in this direction may be limited. Nevertheless, QUS can provide useful additional information to that provided by axial BMD due in part to different precision and accuracy errors and to biological discordance. On the whole one could conclude that ultrasound attenuation is due to structural parameters and these variables are also dependent on density.

Anisotropy↗

Standardization of bone mineral density at femoral neck, trochanter and Ward's triangle.

The International Committee for Standards in Bone Measurement (ICSBM) has published standardization formulas for total hip bone mineral density (BMD). In many applications, however, BMD of hip subregions, such as femoral neck (FN), trochanter (TR), and Ward's triangle (WT), are commonly measured. This paper addresses whether the standardization formulas for total hip BMD can be adequately used for hip subregions. We used data from 100 healthy women, from 20 to 80 years old, who had hip BMD measured in both the total hip and hip subregions by a Hologic QDR 2000, a Lunar DPX, and a Norland XR26 Mark II. The same women were used by ICSBM for the standardization of total hip BMD. In addition, we used data of 3139 patients from a clinical trial to validate our results. We derived standardization formulas for FN, TR, and WT using the same statistical method as that used for total hip BMD. We applied both total hip calibration formulas and subregion-specific formulas to the data and compared the corresponding effect. We found that the total hip calibration formulas can partially reduce BMD differences between the Hologic and Lunar as well as the Lunar and Norland scanners in hip subregions, but increase differences between the Hologic and Norland scanners. The subregion calibration formulas are most appropriate for calibrating subregion BMD values and their absolute changes, and should be adopted. Standardization is unnecessary for BMD percentage changes in our clinical trial data.

Absorptiometry, Photon↗

Quantitative ultrasound of the tibia depends on both cortical density and thickness.

This study investigated whether tibial speed of sound (SOS; SoundScan 2000, Myriad Ultrasound Systems, Israel) reflects not only bone mineral density (BMD) but also tibial cortical thickness, as assessed by dual-energy X-ray absorptiometry (DXA) and Quantitative CT (QCT) at a site-matched location. The secondary focus of the study was how tibial SOS compares with BMD at the spine and the hip, the most widely used locations for densitometry. Twenty-two young normal (N) and 23 postmenopausal women with spinal fractures (Fx) (mean (SD) age 35 (8) and 70 (5) years) underwent quantitative ultrasound (QUS) SOS measurement at the left tibial midshaft. From site-matched QCT scans (three 3-mm slices spaced along the QUS measurement region), BMD and cortical thickness were computed (QCT-cBMD, QCT-cTh). The cortex in the CT images was then subdivided into three concentric and equally spaced bands, and QCT-cBMD was computed separately for each band. DXA was performed at the mid-tibia (TIB BMD), at the spine (SPINE BMD) and the hip (total hip, HIP BMD). Correlation coefficients between parameters were determined with least-square linear fits. Intergroup differences were assessed by analysis of covariance, whose r2 value reflects the percentage variation in the data explained by group assignment. SOS correlated significantly with site-matched parameters (QCT-cBMD, OCT-cTh and TIB BMD, all r = 0.6, p < 0.001), SPINE BMD and HIP BMD (both r = 0.5, p < 0.001). Multiple regression with both QCT-cBMD and QCT-cTh against SOS yielded r = 0.7 with both parameters contributing significantly. For the cortex band subdivision, SOS correlated better with QCT-cBMD in the outermost band of the cortex (r = 0.67) than with the more central bands (r = 0.59 and r = 0.53). Group assignment could best explain SPINE BMD (r2 = 0.62) and HIP BMD (r2 = 0.51). SOS was comparable to TIB BMD (r2 = 0.3 vs. r2 = 0.35).: Our findings suggest that the tibial SOS measurement depends on both the thickness and density of the tibia, but is more strongly influenced by the density of the cortex near the surface than by its interior parts. The power of tibial ultrasound to discriminate between normal and fracture patients was less than that of spinal and femoral DXA BMD and comparable to site-matched DXA BMD.

Absorptiometry, Photon↗

Calibration and validation of an air-displacement plethysmography method for estimating percentage body fat in an elderly population: a comparison among compartmental models.

BACKGROUND: The use of hydrostatic weighing (HW) to measure body composition in the elderly can be difficult and is based on the assumption of constancy of body compartments. OBJECTIVE: We calibrated and validated a new air-displacement plethysmography (AP) method for measuring body composition in the elderly. DESIGN: A 4-compartment equation for calculating percentage body fat (%BF) that used body density (D(b)), total body water, and bone mineral content was used as the criterion for evaluating %BF estimated by the 2- and 3-compartment models. D(b) was measured by HW [D(b(HW))] and by use of the AP instrument [D(b(AP))] in 30 elderly men and 28 elderly women aged 70-79 y. RESULTS: D(b(AP)) was not significantly different from D(b(HW)). However, analysis of variance showed a significant two-way interaction between sex and compartment model (P < 0.02), indicating that the comparisons between the sexes were different across all compartment models. The %BF calculated for the women was significantly higher than that calculated for the men by both HW and AP and for all compartment models. CONCLUSION: Our data indicate that D(b(AP)) was not significantly different from D(b(HW)). Although differences were seen in %BF between the sexes, we observed no significant differences among the compartment models within each sex for this group of older individuals.

Adipose Tissue↗

Comparison of six calcaneal quantitative ultrasound devices: precision and hip fracture discrimination.

Quantitative ultrasound (QUS) is now accepted as a useful tool in the management of osteoporosis. There are a variety of QUS devices clinically available with a number of differences among them, including their coupling methods, parameter calculation algorithms and sites of measurement. This study evaluated the abilities of six calcaneal QUS devices to discriminate between normal and hip-fractured subjects compared with the established method of dual-energy X-ray absorptiometry (DXA). The short-term and mid-term precisions of these devices were also determined. Thirty-five women (mean age 74.5+/-7.9 years) who had sustained a hip fracture within the past 3 years, and 35 age-matched controls (75.8+/-5.6 years) were recruited. Ultrasound measurements were acquired using six ultrasound devices: three gel-coupled and three water-coupled devices. Bone mineral density was measured at the hip using DXA. Discrimination of fracture patients versus controls was assessed using logistic regression analysis (expressed as age- and BMI-adjusted odds ratios per standard deviation decrease with 95% confidence interval) and receiver operating characteristics (ROC) curve analysis. Measurement precision was standardized to the biological range (sCV). The sCV ranged from 3.14% to 5.5% for speed of sound (SOS) and from 2.45% to 6.01% for broadband ultrasound attenuation (BUA). The standardized medium-term precision ranged from 4.33% to 8.43% for SOS and from 2.77% to 6.91% for BUA. The pairwise Pearson correlation coefficients between different devices was highly significant (SOS, r = 0.79-0.93; BUA, r = 0.71-0.92). QUS variables correlated weakly, though significantly, with femoral BMD (SOS, r = 0.30-0.55; BUA, r = 0.35-0.61). The absolute BUA and SOS values varied among devices. The gel-coupled devices generally had a higher SOS than water-coupled devices. Bone mineral density (BMD) and BUA were weakly correlated with weight (r = 0.48-0.57 for BMD and r = 0.18-0.54 for BUA), whereas SOS was independent of weight. All the QUS devices gave similar, statistically significant hip fracture discrimination for both SOS and BUA measures. The odds ratios for SOS (2.1-2.8) and BUA (2.4-3.4) were comparable to those for femoral BMD (2.6-3.5), as were the area under the curve (SOS, 0.65-0.71; BUA, 0.62-0.71; BMD, 0.65-0.74) from ROC analysis. Within the limitation of the sample size all devices show similar diagnostic sensitivity.

Absorptiometry, Photon↗

Assessment of a new quantitative ultrasound calcaneus measurement: precision and discrimination of hip fractures in elderly women compared with dual X-ray absorptiometry.

The incidence of osteoporotic hip fracture increases in postmenopausal women with low hip bone mineral density (BMD). Dual X-ray absorptiometry (DXA) is the most commonly used technique for the assessment of bone status and provides good measurement precision. However, DXA affords little information about bone architecture. Quantitative ultrasound (QUS) systems have been developed to evaluate bone status for assessment of fracture risk. Our study was designed to assess a new QUS system from Hologic, the Sahara; to compare it with a previous model, the Walker-Sonix UBA 575+; and to investigate whether it is able to discriminate between women with and without fracture. Using both ultrasound devices, the measurements were performed at the heels of 33 postmenopausal women who had recently sustained hip fracture. A control group of 35 age-matched postmenopausal women was recruited for comparison. The total, neck and trochanter femoral BMD values were assessed using DXA for both groups. QUS and DXA measurements were significantly lower in fractured patients (p < 0.005) than in the control group. The short-term, mid-term and standardized short-term precisions were used to evaluate the reproducibility of the two QUS systems. The Sahara showed a better standardized coefficient of variation for broadband ultrasound attenuation (BUA) than did the UBA 575+ (p < 0.001). The correlation of BUA and speed of sound (SOS) between the two QUS devices was highly significant, with an r value of 0.92 for BUA and 0.91 for SOS. However, the correlation between DXA and ultrasound parameters ranged from 0.28 to 0.44. We found that ultrasound measurements at the heel were significant discriminators of hip fractures with odds ratios (OR) ranging from 2.7 to 3.2. Even after adjusting the logistic regressions for total, neck or trochanter femoral BMD, QUS variables were still significant independent discriminators of hip fracture. The areas under the ROC curves of each ultrasound parameter ranged from 0.75 to 0.78, and compared very well with femoral neck BMD (p > 0.05). In conclusion, our study indicated that the calcaneal QUS variables, as measured by the Sahara system can discriminate hip fracture patients equally as well as hip DXA.

Absorptiometry, Photon↗

Estimation of wrist fracture load using phalangeal speed of sound: an in vitro study.

This study aimed to evaluate the ability of speed of sound (SOS) measured at the phalanges to estimate simulated wrist fracture load and stress. SOS was measured along the proximal phalanges of the second, third and fourth fingers using an ultrasound (US) system operating in axial transmission mode. The bone mineral density (BMD) of the radius and the phalanges was also measured with quantitative computed tomography (QCT) and dual x-ray absorptiometry (DXA), and the combined cortical thickness (CCT) of the phalanges was measured from hand radiographs. After the measurements were completed, the radius was excised from the cadaver, embedded in polymethylmethacrylate and tested to failure on a servohydraulic testing machine. The configuration of the radius was chosen to simulate a fall onto the hand. Linear regression analysis showed a highly significant correlation between SOS (r = 0.76-0.94, p < 0.001), CCT (r = 0.86-0.90, p < 0.001) and BMD (r = 0.92-0.96, p < 0.0001) in the three proximal phalanges measured. SOS, BMD and CCT were significant predictors of fracture load (r = 0.60-0.69, p < 0.03) and stress (r = 0.65-0.77, p < 0.02). Cortical area and bone mineral content (BMC) of the radius were consistently higher predictors of fracture load (r = 0.76-0.82, p < 0.01 for area and r = 0.78-0.88, p < 0.01 for BMC) than BMD. The correlation of BMC and area was poorer with fracture stress. In a step-wise regression analysis using both phalangeal BMD and SOS, only SOS remained a significant predictor of fracture stress. In forward stepwise regression analysis, both cortical area and SOS were entered into the regression model to estimate fracture load. Only SOS remained significant in the model for estimating fracture stress. Phalangeal BMD was only entered in the combined model with the cortical area at the 4% site (r = 0.84, p = 0.002). Phalangeal SOS is a useful parameter in the assessment of bone status of the radius.

Absorptiometry, Photon↗

Waist circumference and sagittal diameter reflect total body fat better than visceral fat in older men and women. The Health, Aging and Body Composition Study.

The validity of waist circumference and sagittal diameter as surrogate measures of visceral fat were assessed using preliminary cross-sectional data from the Health, Aging and Body Composition Study, a cohort of 3,075 men and women aged 70-79. Weight, body mass index, waist circumference, waist/thigh ratio, and sagittal diameter were compared by correlation, graphical analysis, and regression to total body fat as measured by dual-energy X-ray absorptiometry (Hologic 4500A), and to visceral fat area as measured by computerized tomography. We included 2,830 persons, 1,439 women and 1,391 men with complete data on all measurements. For both men and women, all measurements were strongly correlated with both total body fat and visceral fat except the waist/thigh ratio. However, waist circumference, sagittal diameter, weight, and body mass index were more closely related to total body fat than to visceral fat area (R2 for the linear regression of waist circumference on total body fat was 0.69 in women and men; R2 for linear regression of waist circumference on visceral fat area was 0.40 in women, and 0.49 in men). These data suggest that the contribution of visceral fat to health risks will be better assessed by directly measuring this fat depot.

Adipose Tissue↗

Measurement of fat mass using DEXA: a validation study in elderly adults.

The accuracy of total body fat mass and leg fat mass measurements by fan-beam dual-energy X-ray absorptiometry (DEXA) was assessed in 60 healthy elderly subjects (aged 70-79 yr). Total fat and leg fat mass at four leg regions (total leg, thigh, midthigh, and calf) were measured with the QDR 4500A (Hologic, Waltham, MA). The four-compartment model and multislice computed tomography scans were selected as criterion methods for total fat and leg fat mass, respectively. Total fat mass from DEXA was positively associated with fat mass from the four-compartment model with a standard error of the estimate ranging from 1.4 to 1.6 kg. DEXA fan-beam tended to overestimate fat mass for total leg and total thigh fat mass, whereas only marginal differences in fat mass measurements at the midthigh and calf were demonstrated (</=0.08 kg, P < 0.0005). Although there were significant differences between DEXA fan beam and the criterion methods, these differences were of small magnitude, suggesting that DEXA is an accurate method for measurement of fat mass for the elderly.

Absorptiometry, Photon↗

Evaluation of a new body composition phantom for quality control and cross-calibration of DXA devices.

This study evaluated a new body composition phantom and its use for quality control and cross-calibration of dual-energy X-ray absorptiometry (DXA) instruments for measurements of body composition. We imaged the variable composition phantom (Lunar, Madison, WI) on eight different DXA devices. Deviations of up to 7% fat were observed when we compared the percent fat values measured by the different devices with the nominal values provided by the manufacturer. Absolute precision error of percent fat measurements for the phantom ranged from 0.6 to 0.8%. The phantom's percent fat values were also compared with whole body composition measurements from 130 female and male volunteers. The phantom detected differences in percent fat values that were similar to those found by comparing in vivo measurements with values from different DXA scanner models from the same manufacturer. When comparing different models of scanners from different manufacturers, such as the Hologic QDR-4500 and the Lunar DPX-IQ, the phantom showed a different relationship than was seen for patients. Therefore, corrections or comparisons based on the phantom data alone would be incorrect. In conclusion, the Lunar variable composition phantom is capable of accurately measuring the fat calibration of DXA devices and may be suitable for cross-sectional cross-calibration between scanners from the same manufacturer; however, for comparison of DXA scanners from different manufacturers, in vivo cross-calibration is still the only accurate method. The phantom may be used in longitudinal quality control to verify an instrument's temporal stability.

Absorptiometry, Photon↗

Comparison of an imaging heel quantitative ultrasound device (DTU-one) with densitometric and ultrasonic measurements.

The purpose of this study was to evaluate a new imaging ultrasound scanner for the heel, the DTU-one (Osteometer MediTech, Denmark), by comparing quantitative ultrasound (QUS) results with bone mineral density (BMD) of the heel and femur from dual X-ray absorptiometry (DXA), and by comparing the DTU-one with another QUS device, the UBA 575+. The regions of interest in the DXA heel scan were matched with the regions evaluated by the two QUS devices. 134 healthy and 16 osteoporotic women aged 30-84 years old were enrolled in the study. In vivo short-term precision of the DTU-one for broadband ultrasound attenuation (BUA) and speed of sound (SOS) was 2.9% and 0.1%, respectively, and long-term precision was 3.8% and 0.2%, respectively. Highest correlations (r) between QUS and BMD measurements were achieved when comparing DTU-one results with BMD in matched regions of the DXA heel scan. Correlation coefficients (r) were 0.81 for BUA and SOS. Highest correlations with the UBA 575+ were 0.68 and 0.72, respectively. The comparison of BMD in different femoral sites with BUA and SOS (DTU-one) varied from 0.62 to 0.69 when including the entire study population. The correlation between BMD values within different sites of the femur tended to be higher (from r = 0.81 to 0.93). When comparing BUA with BUA and SOS with SOS on the two QUS devices, the absolute QUS values differed significantly. However, correlations were relatively high, with 0.76 for BUA and 0.82 for SOS. In conclusion, the results of the new quantitative ultrasound device, the DTU-one, are highly correlated (r = 0.8) with results obtained using the UBA 575+ and with BMD in the heel. The precision of the DTU-one is comparable to other QUS devices for BUA and is high for SOS.

Absorptiometry, Photon↗

Factors affecting broadband ultrasound attenuation results of the calcaneus using a gel-coupled quantitative ultrasound scanning system.

This study aimed to assess the factors that may influence the distribution and description of broadband ultrasound attenuation (BUA) and to identify specific criteria for diagnostic consideration when collecting BUA reference data. Two hundred Caucasian women (aged 20-79 years) without a history of atraumatic fractures or medicines known to affect bone metabolism were selected for this study. Medical and menstrual history, medication usage, family history of osteoporosis (FHO), physical activity, activities of daily living (ADL), dietary calcium intake, as well as smoking and alcohol consumption were obtained. Broadband ultrasound attenuation (BUA, dB/MHz) was determined in the right foot using a new gel-coupled ultrasound system. BUA was significantly associated with age (p<0.001), body weight (p<0.001), level of physical activity (p = 0.024) and dietary calcium intake (p = 0.023). Smoking, alcohol and coffee consumption and ADL were not associated with BUA (p>0.05). There were no differences in BUA (p>0.05) between those women who reported taking medications or had diseases (known to not affect bone metabolism), were using contraceptives, taking vitamin/mineral supplements and/or had traumatic fractures and their counterparts who did not report these characteristics. Premenopausal women with a FHO had significantly lower BUA values compared with those without a FHO (p = 0.013). When those participants with a FHO were removed from the sample, the peak BUA value was 1.1-4.4% higher and the variability (SD) was reduced by about 3.3-9.3% depending on which age range was used to define the peak BUA value. Consequently, an additional 4.5% of the population were classified as having a T-score <-2. Our results suggest that the impact on BUA of risk factors such as a FHO, body weight, physical activity and dietary calcium intake is similar to that on bone mineral density obtained by dual-energy X-ray absorptiometry (DXA), and thus provides further information on the comparability of quantitative ultrasound and DXA for assessment of risk of fracture. The criteria for calculating the T-score need further study to determine whether young adults with FHO should be included and what cutoff age range should be used in collecting peak values of quantitative ultrasound parameters.

Adult↗

Radiation exposure in bone mineral density assessment.

Osteoporosis is a systematic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue which leads to diminished biomechanical competence of the skeleton and low-trauma or atraumatic fractures. Due to increased awareness of the impact of osteoporosis on the elderly population, the use of bone densitometric techniques is becoming more widespread. Considerable progress has been made in the development of non-invasive methods for the assessment of the skeleton. While DXA and QCT are commonly used techniques, the popularity of other approaches such as RA, SXA and QUS is gaining grounds. QCT has an advantage over the other techniques in its ability to measure the true volumetric density of trabecular or cortical bone. We therefore present an overview of these current techniques for bone mineral density (BMD) measurements. In the second section we discuss the radiation doses incurred in BMD measurements by patients and methods for reducing patient and staff radiation exposure are given. Studies of radiation dose to patient from DXA confirms that patient dose is small (0.08-4.6 muSv) compared to that given by many other investigations involving ionizing radiation. Fan beam technology with increased resolution has resulted in increase patient dose radiation dose (6.7-31 muSv) but this is still relatively small. Carrying vertebral morphometry using DXA also incurs less radiation dose (< 60 muSv) than standard lateral radiographs QCT has radiation dose (25-360 muSv) comparable to simple radiological examination such as chest X-ray but lower than imaging CT. Radiation dose from other techniques such as RA and SXA are in the same order of magnitude as pencil beam DXA. For pencil beam DXA and SXA systems the time average dose to staff from scatter is very low even with the operator sitting as close as 1 m from the patient during measurement. However the scatter dose from fan beam DXA systems is considerable higher and approaches limits set by regulator bodies for occupational exposure.

Absorptiometry, Photon↗